{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T00:21:20Z","timestamp":1777422080834,"version":"3.51.4"},"reference-count":14,"publisher":"SAGE Publications","issue":"7","license":[{"start":{"date-parts":[[2000,7,1]],"date-time":"2000-07-01T00:00:00Z","timestamp":962409600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ann Otol Rhinol Laryngol"],"published-print":{"date-parts":[[2000,7]]},"abstract":"<jats:p>Cricotracheal resection has been advocated in the management of severe subglottic stenosis. One of the possible complications of this procedure is injury to the recurrent laryngeal nerve (RLN). We describe a new technique in which electrodes are placed directly through the thyroid cartilage to monitor the RLN intraoperatively. Nine cats' left vocal cords were monitored, and 3 cats had unilateral vocal cord injury postoperatively: 1 right cord and 2 left cords. Even though this technique was efficacious, our ability to monitor the RLNs was difficult secondary to difficulty interpreting the nerve monitor's wave morphologies. The future use of RLN nerve monitoring during cricotracheal resection will depend upon the ability to distinguish true stimulation from artifact. Monitoring of the RLN could be beneficial in patients with previous operations for subglottic stenosis.<\/jats:p>","DOI":"10.1177\/000348940010900708","type":"journal-article","created":{"date-parts":[[2014,10,3]],"date-time":"2014-10-03T14:40:52Z","timestamp":1412347252000},"page":"654-657","source":"Crossref","is-referenced-by-count":6,"title":["Recurrent Laryngeal Nerve Monitoring during Cricotracheal Resection"],"prefix":"10.1177","volume":"109","author":[{"given":"Kevin","family":"Cavanaugh","sequence":"first","affiliation":[{"name":"Maywood, Illinois"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Albert H.","family":"Park","sequence":"additional","affiliation":[{"name":"Maywood, Illinois"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2000,7,1]]},"reference":[{"key":"bibr1-000348940010900708","first-page":"185","volume":"161","author":"James AG","year":"1985","journal-title":"Surg Gynecol Obstet"},{"key":"bibr2-000348940010900708","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.1987.01860120037004"},{"key":"bibr3-000348940010900708","first-page":"151","volume-title":"Neuromonitoring in otology and head and neck surgery","author":"Beck DL","year":"1992"},{"key":"bibr4-000348940010900708","doi-asserted-by":"publisher","DOI":"10.1288\/00005537-198812000-00003"},{"key":"bibr5-000348940010900708","doi-asserted-by":"publisher","DOI":"10.1177\/019459989110500304"},{"key":"bibr6-000348940010900708","doi-asserted-by":"crossref","unstructured":"Flisberg K, Lindholm T. Electrical stimulation of the human recurrent laryngeal nerve during thyroid operation. Acta Otolaryngol [Suppl] (Stockh) 1970(suppl 263): 63\u20137.","DOI":"10.3109\/00016487009131523"},{"key":"bibr7-000348940010900708","first-page":"249","volume":"103","author":"Goldstone AC","year":"1990","journal-title":"Otolaryngol Head Neck Surg"},{"key":"bibr8-000348940010900708","doi-asserted-by":"publisher","DOI":"10.1016\/1043-1810(94)90042-6"},{"key":"bibr9-000348940010900708","first-page":"131","volume-title":"Neuromonitoring in otology and head and neck surgery","author":"Lanser MJ","year":"1992"},{"key":"bibr10-000348940010900708","doi-asserted-by":"publisher","DOI":"10.1288\/00005537-199311000-00011"},{"key":"bibr11-000348940010900708","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-199604000-00010"},{"key":"bibr12-000348940010900708","doi-asserted-by":"publisher","DOI":"10.1288\/00005537-199109000-00018"},{"key":"bibr13-000348940010900708","doi-asserted-by":"publisher","DOI":"10.1177\/000348949810701111"},{"key":"bibr14-000348940010900708","doi-asserted-by":"publisher","DOI":"10.1177\/000348949710601102"}],"container-title":["Annals of Otology, Rhinology &amp; Laryngology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/000348940010900708","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/000348940010900708","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T11:19:00Z","timestamp":1777375140000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/000348940010900708"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,7]]},"references-count":14,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2000,7]]}},"alternative-id":["10.1177\/000348940010900708"],"URL":"https:\/\/doi.org\/10.1177\/000348940010900708","relation":{},"ISSN":["0003-4894","1943-572X"],"issn-type":[{"value":"0003-4894","type":"print"},{"value":"1943-572X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,7]]}}}