{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T06:06:09Z","timestamp":1777442769897,"version":"3.51.4"},"reference-count":46,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2021,3,30]],"date-time":"2021-03-30T00:00:00Z","timestamp":1617062400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/501100004493","name":"International Atomic Energy Agency","doi-asserted-by":"publisher","award":["IAEA Research Contract No. 15390\/R0"],"award-info":[{"award-number":["IAEA Research Contract No. 15390\/R0"]}],"id":[{"id":"10.13039\/501100004493","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Appl Spectrosc"],"published-print":{"date-parts":[[2021,6]]},"abstract":"<jats:p>\n                    Conventional methods for measuring the concentration of deuterium in body fluids are by either isotope ratio mass spectrometry or Fourier transform infrared transmission (FT-IR) spectroscopy. The latter method is often preferred as it is less expensive and time consuming; however, having a lower sensitivity means a larger sample volume is required. This study investigated an alternative FT-IR spectroscopic method, attenuated total reflection Fourier transform infrared spectroscopy (ATR FT-IR), which has the potential to provide shorter analysis times while requiring smaller sample volumes. Deuterium was assayed using ATR FT-IR in plasma in the concentration range 0.5 to 2.5\u2009mg\u2009mL\n                    <jats:sup>\u22121<\/jats:sup>\n                    , typical of those observed in tracer dilution measurements of total body water. Minimal sample preparation was required and analysis time was substantially decreased compared to transmission FT-IR. Samples were analyzed with high precision (coefficient of variation (CV)\u2009&lt;\u20090.5%). Precision of assay was maintained when assaying plasma volumes of only 10\u2009\u00b5L . The application of the method to the determination of total body water in humans and animals (horses) was demonstrated. A rapid and simple method for the measurement of deuterium in plasma is described that only requires very small sample volumes, rendering the method suitable for use in pediatrics where blood sampling is required to be kept to a minimum.\n                  <\/jats:p>","DOI":"10.1177\/00037028211002532","type":"journal-article","created":{"date-parts":[[2021,2,26]],"date-time":"2021-02-26T11:05:34Z","timestamp":1614337534000},"page":"698-705","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":2,"title":["Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) Spectroscopy for the Quantitative Analysis of Deuterium in Plasma: Application to Total Body Water Determination in Humans and Other Animals"],"prefix":"10.1177","volume":"75","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2378-279X","authenticated-orcid":false,"given":"Leigh C.","family":"Ward","sequence":"first","affiliation":[{"name":"School of Chemistry and Molecular Biosciences, The University of Queensland, St. Lucia, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2021,3,30]]},"reference":[{"key":"bibr1-00037028211002532","doi-asserted-by":"crossref","unstructured":"D.A. Schoeller. \u201cHydrometry\u201d. In: S.B. Heymsfield, T.G. Lohman, Z. Wang, et\u00a0al., editors. Human Body Composition. Champaign, IL: Human Kinetics, 2005. Chap. 2, Pp. 35\u201350.","DOI":"10.5040\/9781492596950.ch-003"},{"key":"bibr2-00037028211002532","doi-asserted-by":"crossref","unstructured":"J. Speakman, G. Visser, S. Ward, et\u00a0al. \u201cThe Isotope Dilution Method for the Evaluation of Body Composition\u201d. In: J.R. Speakman, editor. Body Composition Analysis of Animals: A Handbook of Non-Destructive Methods. Cambridge: Cambridge University Press, 2001. Chap. 3, Pp. 56\u201398.","DOI":"10.1017\/CBO9780511551741.005"},{"key":"bibr3-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1038\/s41430-020-0580-0"},{"key":"bibr4-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1071\/EA97025"},{"key":"bibr5-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1002\/bms.1200120916"},{"key":"bibr6-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1002\/bms.1200220704"},{"key":"bibr7-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1970.28.3.354"},{"issue":"5","key":"bibr8-00037028211002532","first-page":"885","volume":"69","author":"Graystone J.","year":"1967","journal-title":"J. Lab. Clin. Med"},{"key":"bibr9-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1093\/clinchem\/14.11.1112"},{"key":"bibr10-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1007\/BF02933321"},{"key":"bibr11-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.2000.tb06469.x"},{"key":"bibr12-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1093\/jn\/132.6.1725S"},{"issue":"3","key":"bibr13-00037028211002532","first-page":"159","volume":"50","author":"Cornish B.","year":"1996","journal-title":"Eur. J. Clin. Nutr"},{"key":"bibr14-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1093\/clinchem\/45.7.1077"},{"key":"bibr15-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1177\/15648265020233S127"},{"key":"bibr16-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1021\/ac60041a021"},{"key":"bibr17-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1960.15.2.309"},{"key":"bibr18-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1016\/0003-2697(79)90728-0"},{"key":"bibr19-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1007\/BF00583917"},{"issue":"1","key":"bibr20-00037028211002532","first-page":"170","volume":"82","author":"Wang J.","year":"1973","journal-title":"J. Lab. Clin. Med"},{"key":"bibr21-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1093\/ajcn\/41.2.363"},{"issue":"3","key":"bibr22-00037028211002532","first-page":"110","volume":"13","author":"Blagojevic N.","year":"1990","journal-title":"Australas. Phys. Eng. Sci. Med"},{"key":"bibr23-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1038\/ejcn.2012.164"},{"key":"bibr24-00037028211002532","first-page":"135","volume":"92","author":"Bertani R.","year":"2002","journal-title":"Ann. Chim"},{"issue":"10","key":"bibr25-00037028211002532","first-page":"639","volume":"31","author":"Fusch C.","year":"1993","journal-title":"Eur. J. Clin. Chem. Clin. Biochem"},{"key":"bibr26-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1039\/C8RA03312A"},{"key":"bibr27-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1006\/abio.1997.2136"},{"key":"bibr28-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1051\/analusis:1999133"},{"key":"bibr29-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1146\/annurev.physchem.51.1.381"},{"key":"bibr30-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1007\/s10967-010-0828-6"},{"key":"bibr31-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1016\/j.bbamem.2006.02.011"},{"key":"bibr32-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1002\/1097-0282(2000)55:5<373::AID-BIP1011>3.0.CO;2-U"},{"key":"bibr33-00037028211002532","unstructured":"International Atomic Energy Agency (IAEA). Introduction to Body Composition Assessment Using the Deuterium Dilution Technique with Analysis of Saliva Samples by Fourier Transform Infrared Spectrometry. IAEA Human Health Series, No. 12. Vienna, Austria: Marketing and Sales Unit, Publishing Section International Atomic Energy Agency, 2010. https:\/\/www-pub.iaea.org\/MTCD\/Publications\/PDF\/Pub1450_web.pdf [accessed Feb 24 2021]."},{"key":"bibr34-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1007\/s00455-006-9072-1"},{"key":"bibr35-00037028211002532","doi-asserted-by":"publisher","DOI":"10.2527\/jas.2015-9837"},{"key":"bibr36-00037028211002532","doi-asserted-by":"publisher","DOI":"10.2307\/2532051"},{"key":"bibr37-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"bibr38-00037028211002532","unstructured":"International Atomic Energy Agency (IAEA). \u201cIntroduction to Body Composition Assessment Using the Deuterium Dilution Technique with Analysis of Urine Samples by Isotope Ratio Mass Spectrometry\u201d. IAEA Hum. Heal. Series, No. 13. Vienna, Austria: Marketing and Sales Unit, Publishing Section International Atomic Energy Agency, 2010. https:\/\/www-pub.iaea.org\/MTCD\/Publications\/PDF\/Pub1451_web.pdf [accessed Feb 24 2021]."},{"key":"bibr39-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1021\/ac7025892"},{"key":"bibr40-00037028211002532","unstructured":"A. Rein, F. Higgins, T. Preston. \u201cApplication of the Agilent 4500 Series FTIR to the Stable Isotope Technique for Assessing Intake of Human Milk in Breastfed Infants\u201d. Agilent Technologies, Inc. Application Note. 2014. https:\/\/www.agilent.com\/cs\/library\/applications\/5991-3531EN.pdf [accessed May 28 2020]."},{"key":"bibr41-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1039\/an9861100661"},{"key":"bibr42-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1071\/A97037"},{"key":"bibr43-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1366\/000370206778397371"},{"key":"bibr44-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1515\/cclm.1988.26.11.715"},{"key":"bibr45-00037028211002532","doi-asserted-by":"publisher","DOI":"10.1117\/1.1917844"},{"issue":"10","key":"bibr46-00037028211002532","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.2460\/ajvr.1997.58.10.1060","volume":"58","author":"Andrews F.M.","year":"1997","journal-title":"Am. J. Vet. Res"}],"container-title":["Applied Spectroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/00037028211002532","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/00037028211002532","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/00037028211002532","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T12:18:26Z","timestamp":1777378706000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/00037028211002532"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,30]]},"references-count":46,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,6]]}},"alternative-id":["10.1177\/00037028211002532"],"URL":"https:\/\/doi.org\/10.1177\/00037028211002532","relation":{},"ISSN":["0003-7028","1943-3530"],"issn-type":[{"value":"0003-7028","type":"print"},{"value":"1943-3530","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,30]]}}}