{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:28:29Z","timestamp":1790818109623,"version":"4.1.0"},"reference-count":30,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T00:00:00Z","timestamp":1779753600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Ann Clin Biochem"],"abstract":"<jats:p>Venepuncture is traditionally regarded as the gold standard for collecting blood samples. However, self-collected capillary blood sampling has emerged as a practical alternative in various settings, fostering a more patient-centred, personalised, and cost-effective healthcare model. The NHS UK strategic plans published in 2023\u20132025 emphasise a shift in care from hospitals to community settings and from treating illness to preventing it. Self-collected capillary sampling with back-to-laboratory analysis is a strong option to support the shift of healthcare provision into the community while maintaining high-quality results and direct delivery to the electronic patient record.<\/jats:p>\n                  <jats:p>Routine clinical laboratories, particularly those within the NHS, should consider this potential delivery model. However, most assay manufacturers do not currently include capillary blood in their instructions for use. Consequently, UK Accreditation Service-accredited laboratories that wish to conduct routine tests using capillary blood must perform additional comparison studies to obtain accreditation. If this is not done, they must be able to distinguish between non-accredited (capillary blood) and accredited (venous blood) tests.<\/jats:p>\n                  <jats:p>This document has been created to guide clinical laboratorians through the rapidly evolving field of patient-centric sampling and how to enable safe working within a routine clinical laboratory.<\/jats:p>","DOI":"10.1177\/00045632261454300","type":"journal-article","created":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T06:49:44Z","timestamp":1779864584000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":2,"title":["UK recommendations for the validation and adoption of capillary blood testing within the routine clinical laboratory: Consensus opinion from the LabMed patient-centred testing and sampling (PaCTS) group"],"prefix":"10.1177","author":[{"given":"Timothy","family":"Woolley","sequence":"first","affiliation":[{"name":"Inuvi Diagnostics"},{"name":"Patient-Centred Testing &amp; Sampling (PaCTS) Group, Association for Laboratory Medicine (LabMed), London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9012-0932","authenticated-orcid":false,"given":"Sophie","family":"Hepburn","sequence":"additional","affiliation":[{"name":"Patient-Centred Testing &amp; Sampling (PaCTS) Group, Association for Laboratory Medicine (LabMed), London, UK"},{"name":"Raigmore Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-9164-292X","authenticated-orcid":false,"given":"Karen","family":"Perkins","sequence":"additional","affiliation":[{"name":"Patient-Centred Testing &amp; Sampling (PaCTS) Group, Association for Laboratory Medicine (LabMed), London, UK"},{"name":"Blood Sciences, Lancashire &amp; South Cumbria Pathology Network, Preston, Lancashire, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,5,26]]},"reference":[{"key":"e_1_3_4_2_2","unstructured":"Task Force. Direct-to-Consumer testing (TF-DTCT). https:\/\/www.eflm.eu\/site\/who-we-are\/task-forces\/tf-direct-to-consumer-testing. (accessed December 15 2025)."},{"key":"e_1_3_4_3_2","doi-asserted-by":"publisher","DOI":"10.1515\/cclm-2022-1227"},{"key":"e_1_3_4_4_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj-2025-085546"},{"key":"e_1_3_4_5_2","doi-asserted-by":"crossref","unstructured":"Gonz\u00e1lez \u00c1 Deza S Maroto-Garc\u00eda J et al. Capillary blood in core laboratories: current and future challenges. Clin Chem Lab Med 2026; 64: 752-766. https:\/\/doi.org\/10.1515\/cclm-2025-0888 Epub ahead of print 14.","DOI":"10.1515\/cclm-2025-0888"},{"key":"e_1_3_4_6_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12874-025-02599-x"},{"key":"e_1_3_4_7_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmjoq-2020-001192"},{"key":"e_1_3_4_8_2","doi-asserted-by":"publisher","DOI":"10.1080\/13814788.2025.2501309"},{"key":"e_1_3_4_9_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12913-022-08782-w"},{"key":"e_1_3_4_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10900-013-9681-1"},{"key":"e_1_3_4_11_2","unstructured":"NHS England. Fit for the future: 10 year health plan for England. https:\/\/www.england.nhs.uk\/long\/term-plan\/. (accessed 15 December 2025)."},{"key":"e_1_3_4_12_2","unstructured":"Health and social care service renewal framework. https:\/\/www.gov.scot\/publications\/health-social-care-service-renewal-framework. (accessed December 15 2025)."},{"key":"e_1_3_4_13_2","unstructured":"Health and social care NI \u2013 three year plan. https:\/\/www.health-ni.gov.uk\/publications\/health-and-social-care-ni-three-year-plan. (accessed December 15 2025)."},{"key":"e_1_3_4_14_2","unstructured":"Diagnostics recovery and transformation strategy for Wales 2023 to 2025. https:\/\/www.gov.wales\/diagnostics-recovery-and-transformation-strategy-wales-2023-2025. (accessed December 15 2025)."},{"key":"e_1_3_4_15_2","unstructured":"The Patients Association. Patient experience of diagnostics report. https:\/\/www.patients-association.org.uk\/news\/patient-experience-of-diagnostics-report. (2024). (accessed 18 December 2025)."},{"key":"e_1_3_4_16_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0304155"},{"key":"e_1_3_4_17_2","doi-asserted-by":"publisher","DOI":"10.1080\/17576180.2025.2580284"},{"key":"e_1_3_4_18_2","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2023.2170783"},{"key":"e_1_3_4_19_2","doi-asserted-by":"crossref","unstructured":"Woolley T Rutter E Fitzgerald L et al. Automatic for the people: an introduction to self-collected capillary blood testing. Journal of Patient Centricity. 2026 In press.","DOI":"10.57264\/jpc-2026-0002"},{"key":"e_1_3_4_20_2","doi-asserted-by":"publisher","DOI":"10.1515\/cclm-2024-0508"},{"key":"e_1_3_4_21_2","unstructured":"Medical device alert (MDA\/2020\/015). https:\/\/assets.publishing.service.gov.uk\/media\/5eda591986650c4abe1efd1b\/MDA-2020-015_Final.pdf. (accessed September 12 2025)."},{"key":"e_1_3_4_22_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.p1898"},{"key":"e_1_3_4_23_2","doi-asserted-by":"publisher","DOI":"10.1515\/cclm-2023-1072"},{"key":"e_1_3_4_24_2","doi-asserted-by":"publisher","DOI":"10.11613\/BM.2015.034"},{"key":"e_1_3_4_25_2","volume-title":"Assessment of equivalence or suitability of specimen types for medical laboratory measurement procedures","author":"CLSI","year":"2024","unstructured":"CLSI. Assessment of equivalence or suitability of specimen types for medical laboratory measurement procedures. 2nd ed. Clinical and Laboratory Standards Institute, 2024. CLSI guideline EP35.","edition":"2"},{"key":"e_1_3_4_26_2","doi-asserted-by":"publisher","DOI":"10.4155\/bio-2018-0067"},{"key":"e_1_3_4_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiochem.2025.110965"},{"key":"e_1_3_4_28_2","volume-title":"Defining, Establishing, and Verifying Reference Intervals in the Clinical Laboratory","author":"CLSI","year":"2020","unstructured":"CLSI. Defining, Establishing, and Verifying Reference Intervals in the Clinical Laboratory. 3rd ed. Clinical and Laboratory Standards Institute, 2020. CLSI guideline EP28.","edition":"3"},{"key":"e_1_3_4_29_2","unstructured":"International Organization for Standardization. ISO 15189:2022 Medical laboratories \u2014 Requirements for quality and competence. Geneva 2022. Available from: www.iso.org\/standard\/76677.html"},{"key":"e_1_3_4_30_2","doi-asserted-by":"publisher","DOI":"10.1177\/00045632211050531"},{"key":"e_1_3_4_31_2","unstructured":"EFLM biological variation database. https:\/\/biologicalvariation.eu. (accessed November 19 2025)."}],"container-title":["Annals of Clinical Biochemistry: International Journal of Laboratory Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/00045632261454300","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/00045632261454300","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/00045632261454300","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T07:20:21Z","timestamp":1780125621000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/00045632261454300"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,26]]},"references-count":30,"alternative-id":["10.1177\/00045632261454300"],"URL":"https:\/\/doi.org\/10.1177\/00045632261454300","relation":{},"ISSN":["0004-5632","1758-1001"],"issn-type":[{"value":"0004-5632","type":"print"},{"value":"1758-1001","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,26]]},"article-number":"00045632261454300"}}