{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T13:39:54Z","timestamp":1777901994530,"version":"3.51.4"},"reference-count":18,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"name":"the Science Plan Fund of Guangzhou","award":["202103000079"],"award-info":[{"award-number":["202103000079"]}]},{"name":"National Key Research and Development Program of China","award":["2020YFC2005204"],"award-info":[{"award-number":["2020YFC2005204"]}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Science Progress"],"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>In this study, we sought to validate the effectiveness of an automated audiometry system in quiet (AA) and noisy environments (AA-N) by comparing the air pure-tone thresholds obtained by AA to those obtained by traditional manual audiometry (MA).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In this cross-sectional study, 150 participants with or without hearing loss were tested (age: 11\u201384 years; female: 57.3%). Air conduction thresholds were assessed by MA, AA, and AA-N in a quiet or noisy sound booth.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>In participants without hearing loss, 94.5% and 96% of the threshold comparisons differed between MA versus AA and AA versus AA-N within 10\u2005dB HL or less. In participants with hearing loss, there was no statistically significant difference between the three testing conditions at any frequency ( p\u2009&gt;\u20090.05). The hearing threshold difference in the poor hearing ear in participants with a bilateral difference \u226540\u2005dB HL was \u221215 and +15\u2005dB HL; however, this difference was not statistically significant when excluding participants with tinnitus.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Automatic audiometry can accurately estimate hearing thresholds and screen for hearing loss even in noisy environments. Nevertheless, the algorithm must be corrected when patients experience tinnitus.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/00368504251324348","type":"journal-article","created":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T03:15:46Z","timestamp":1740539746000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy and time efficiency of an automated commercial audiometer in the evaluation of hearing in quiet and noisy environments"],"prefix":"10.1177","volume":"108","author":[{"given":"Ying","family":"Yi","sequence":"first","affiliation":[{"name":"Otorhinolaryngology Hospital, The First Affiliated Hospital,  Sun Yat-sen University, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xian-Ren","family":"Wang","sequence":"additional","affiliation":[{"name":"Otorhinolaryngology Hospital, The First Affiliated Hospital,  Sun Yat-sen University, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qin","family":"Xiong","sequence":"additional","affiliation":[{"name":"Otorhinolaryngology Hospital, The First Affiliated Hospital,  Sun Yat-sen University, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8058-3634","authenticated-orcid":false,"given":"Guan-Xia","family":"Xiong","sequence":"additional","affiliation":[{"name":"Otorhinolaryngology Hospital, The First Affiliated Hospital,  Sun Yat-sen University, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2025,2,26]]},"reference":[{"key":"bibr1-00368504251324348","doi-asserted-by":"publisher","DOI":"10.1016\/S2214-109X(21)00447-2"},{"key":"bibr2-00368504251324348","volume-title":"World report on hearing","year":"2020"},{"key":"bibr3-00368504251324348","doi-asserted-by":"publisher","DOI":"10.1177\/0194599813501461"},{"key":"bibr4-00368504251324348","doi-asserted-by":"publisher","DOI":"10.1097\/01.aud.0000436255.53747.a4"},{"key":"bibr5-00368504251324348","first-page":"1","volume":"17","author":"Manchaiah V","year":"2021","journal-title":"Int J Audiol"},{"key":"bibr6-00368504251324348","doi-asserted-by":"publisher","DOI":"10.1080\/14992027.2020.1814432"},{"key":"bibr7-00368504251324348","doi-asserted-by":"publisher","DOI":"10.2471\/BLT.18.227876"},{"key":"bibr8-00368504251324348","doi-asserted-by":"publisher","DOI":"10.1177\/0003489420902162"},{"key":"bibr9-00368504251324348","doi-asserted-by":"publisher","DOI":"10.1055\/s-0041-1728778"},{"key":"bibr10-00368504251324348","doi-asserted-by":"publisher","DOI":"10.3766\/jaaa.16002"},{"key":"bibr11-00368504251324348","doi-asserted-by":"publisher","DOI":"10.1080\/14992027.2016.1178858"},{"key":"bibr12-00368504251324348","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-147-8-200710160-00010"},{"key":"bibr13-00368504251324348","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2006.07.007"},{"key":"bibr14-00368504251324348","doi-asserted-by":"publisher","DOI":"10.1055\/s-0035-1571271"},{"key":"bibr15-00368504251324348","doi-asserted-by":"publisher","DOI":"10.3402\/gha.v2i0.1932"},{"key":"bibr16-00368504251324348","doi-asserted-by":"publisher","DOI":"10.1089\/tmj.2009.0143"},{"key":"bibr17-00368504251324348","doi-asserted-by":"publisher","DOI":"10.3109\/14992027.2011.553206"},{"key":"bibr18-00368504251324348","doi-asserted-by":"publisher","DOI":"10.1515\/jib-2022-0004"}],"container-title":["Science Progress"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/00368504251324348","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/00368504251324348","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/00368504251324348","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T11:15:10Z","timestamp":1777634110000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/00368504251324348"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,1]]}},"alternative-id":["10.1177\/00368504251324348"],"URL":"https:\/\/doi.org\/10.1177\/00368504251324348","relation":{},"ISSN":["0036-8504","2047-7163"],"issn-type":[{"value":"0036-8504","type":"print"},{"value":"2047-7163","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1]]},"article-number":"00368504251324348"}}