{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T13:44:33Z","timestamp":1777902273714,"version":"3.51.4"},"reference-count":25,"publisher":"SAGE Publications","issue":"8","license":[{"start":{"date-parts":[[2013,7,3]],"date-time":"2013-07-03T00:00:00Z","timestamp":1372809600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["SIMULATION"],"published-print":{"date-parts":[[2014,8]]},"abstract":"<jats:p>\n                    With ever-rising energy demand and diminishing sources of inexpensive energy resources, energy conservation has become an increasingly important topic. Building heating, ventilation, and air conditioning (HVAC) systems are considered to be a prime target for energy conservation due to their significant contribution to commercial buildings\u2019 energy consumption in the US. Knowing a building\u2019s occupancy plays a crucial role in implementing demand-response HVAC controls, with a corresponding potential for reduction of HVAC energy consumption, especially in office buildings. This paper evaluates occupancy modeling (both binary detection and multi-class estimation) using twelve ambient sensor variables. Performance of six machine-learning techniques is evaluated in both single-occupancy and multi-occupancy offices. Of the six, the decision-tree technique yielded the best overall accuracy (i.e. 96.0% to 98.2%) and root mean square error (RMSE) (i.e. 0.109 to 0.156). The contribution of each individual ambient sensor variable is evaluated via information gain. It is found that CO\n                    <jats:sub>2<\/jats:sub>\n                    , door status, and light variables have important contributions to the final modeling results. It is observed that the overall accuracy generally increases as the number of sensors increases. This paper also examines the possibility of building a global occupancy model, and explores the reasons for low performance of global occupancy estimation. Lastly, the occupancy model is used to estimate and visualize the accumulative room and thermal zone usage in an office test-bed building for three months. The results reveal that the effective vacancy accounts for a substantial portion of the operational hours, varying from 19.8% to 29.8% with an average of 23.3%, which bears significant potential for energy savings. Furthermore, the authors simulated HVAC energy consumption of the test-bed building for three months in DesignBuilder and EnergyPlus, and compared energy consumption of occupancy-based demand-response HVAC controls using the authors\u2019 occupancy-modeling results to the conventional HVAC controls currently implemented in the test-bed building. The results demonstrate that 20% of gas and 18% of electricity could be effectively saved if occupancy-based demand-response HVAC control is implemented.\n                  <\/jats:p>","DOI":"10.1177\/0037549713489918","type":"journal-article","created":{"date-parts":[[2013,7,4]],"date-time":"2013-07-04T04:10:33Z","timestamp":1372911033000},"page":"960-977","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":152,"title":["A systematic approach to occupancy modeling in ambient sensor-rich buildings"],"prefix":"10.1177","volume":"90","author":[{"given":"Zheng","family":"Yang","sequence":"first","affiliation":[{"name":"Sonny Astani Department of Civil & Environmental Engineering, University of Southern California, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nan","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Construction Management, Tsinghua University, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Burcin","family":"Becerik-Gerber","sequence":"additional","affiliation":[{"name":"Sonny Astani Department of Civil & Environmental Engineering, University of Southern California, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Orosz","sequence":"additional","affiliation":[{"name":"Information Sciences Institute, University of Southern California, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2013,7,3]]},"reference":[{"key":"bibr1-0037549713489918","volume-title":"Building energy data book","author":"US Department of Energy","year":"2011"},{"key":"bibr2-0037549713489918","doi-asserted-by":"publisher","DOI":"10.1098\/rsta.2009.0212"},{"key":"bibr3-0037549713489918","doi-asserted-by":"publisher","DOI":"10.1145\/1878431.1878433"},{"key":"bibr4-0037549713489918","doi-asserted-by":"publisher","DOI":"10.1016\/j.buildenv.2010.07.008"},{"key":"bibr5-0037549713489918","doi-asserted-by":"publisher","DOI":"10.2306\/scienceasia1513-1874.2001.27.279"},{"key":"bibr6-0037549713489918","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2010.06.006"},{"key":"bibr7-0037549713489918","volume-title":"49th IEEE Conference on Decision and Control (CDC)","author":"Wang H"},{"key":"bibr8-0037549713489918","volume-title":"BuildSys \u201909 Proceedings of the First ACM Workshop on Embedded Sensing Systems for Energy-Efficiency in Buildings","author":"Erickson VL"},{"key":"bibr9-0037549713489918","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2010.09.014"},{"key":"bibr10-0037549713489918","volume-title":"Proceedings of the 48th IEEE Conference on Decision and Control, 2009 held jointly with the 2009 28th Chinese Control Conference","author":"Meyn A"},{"key":"bibr11-0037549713489918","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2005.12.001"},{"key":"bibr12-0037549713489918","volume-title":"SimAUD \u201911 Proceedings of the 2011 Symposium on Simulation for Architecture and Urban Design","author":"Hailemariam E"},{"key":"bibr13-0037549713489918","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2010.01.016"},{"key":"bibr14-0037549713489918","volume-title":"Presented at: 2011 International Green Computing Conference and Workshops (IGCC)","author":"Melfi R"},{"key":"bibr15-0037549713489918","volume-title":"Presented at: 2nd IEEE International Workshop on Computational Advances in Multi-Sensor Adaptive Processing, 2007 [CAMPSAP 2007]","author":"Hutchins J"},{"key":"bibr16-0037549713489918","doi-asserted-by":"publisher","DOI":"10.1023\/A:1007465528199"},{"key":"bibr17-0037549713489918","volume-title":"Proceedings from the International Joint Conference on Artificial Intelligence","author":"Kohavi R"},{"key":"bibr18-0037549713489918","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-60327-241-4_13"},{"key":"bibr19-0037549713489918","volume-title":"Neural networks: a comprehensive foundation","author":"Haykin S.","year":"1998","edition":"2"},{"key":"bibr20-0037549713489918","volume-title":"Proceedings of the Fifteenth International Conference on Machine Learning","author":"Friedman N"},{"key":"bibr21-0037549713489918","first-page":"369","author":"Bouckaert RR","year":"2008","journal-title":"Artificial Intelligence Tools 11.3"},{"key":"bibr22-0037549713489918","volume-title":"Pruning decision trees and lists","author":"Frank E.","year":"2000"},{"key":"bibr23-0037549713489918","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4757-1904-8"},{"key":"bibr24-0037549713489918","volume-title":"Building energy efficiency and sustainability","author":"Johnson Controls Inc","year":"2010"},{"key":"bibr25-0037549713489918","volume-title":"Smart home and intelligent building control","author":"ABB Inc","year":"2010"}],"container-title":["SIMULATION"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0037549713489918","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0037549713489918","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0037549713489918","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T11:24:45Z","timestamp":1777634685000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0037549713489918"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,7,3]]},"references-count":25,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2014,8]]}},"alternative-id":["10.1177\/0037549713489918"],"URL":"https:\/\/doi.org\/10.1177\/0037549713489918","relation":{},"ISSN":["0037-5497","1741-3133"],"issn-type":[{"value":"0037-5497","type":"print"},{"value":"1741-3133","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,7,3]]}}}