{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T13:44:52Z","timestamp":1777902292433,"version":"3.51.4"},"reference-count":31,"publisher":"SAGE Publications","issue":"8","license":[{"start":{"date-parts":[[2014,4,15]],"date-time":"2014-04-15T00:00:00Z","timestamp":1397520000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["SIMULATION"],"published-print":{"date-parts":[[2014,8]]},"abstract":"<jats:p>This study utilized energy simulation in support of a forensic pathology time-of-death analysis for a corpse discovered in a single-family residence two years prior to the study. In order to produce an accurate estimate of the interior temperature profile at the time of death, a thermal model was constructed using EnergyPlus and calibrated using environmental monitoring data from the site. The calibration methods used in the study draw from several precedents and are presented in detail. The thermal model was able to predict the temperature in the room of interest within 1.4\u00b0C (2.5\u00b0F) with 90% confidence. This model was then altered to account for known differences between the monitoring period and the period of interest, and used to predict what the temperature profile had been at the time of death. This study adds to a small body of work that compares simulated to measured performance data for unconditioned spaces, which should have a growing relevance as building energy performance simulation tools are used to model passive strategies.<\/jats:p>","DOI":"10.1177\/0037549714528744","type":"journal-article","created":{"date-parts":[[2014,4,16]],"date-time":"2014-04-16T02:34:50Z","timestamp":1397615690000},"page":"1007-1018","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["EnergyPlus as a forensic tool: Thermal reconstruction of a crime scene using calibrated simulation"],"prefix":"10.1177","volume":"90","author":[{"given":"Nathan","family":"Brown","sequence":"first","affiliation":[{"name":"Loisos + Ubbelohde, Alameda, CA, USA"},{"name":"California College of the Arts, Oakland, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M Susan","family":"Ubbelohde","sequence":"additional","affiliation":[{"name":"Loisos + Ubbelohde, Alameda, CA, USA"},{"name":"University of California, Berkeley, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George","family":"Loisos","sequence":"additional","affiliation":[{"name":"Loisos + Ubbelohde, Alameda, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Santosh","family":"Philip","sequence":"additional","affiliation":[{"name":"Loisos + Ubbelohde, Alameda, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ibone","family":"Santiago","sequence":"additional","affiliation":[{"name":"Loisos + Ubbelohde, Alameda, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2014,4,15]]},"reference":[{"key":"bibr1-0037549714528744","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2010.12.039"},{"key":"bibr2-0037549714528744","doi-asserted-by":"publisher","DOI":"10.1177\/1042391509105596"},{"key":"bibr3-0037549714528744","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2008.09.033"},{"key":"bibr4-0037549714528744","first-page":"226","volume":"112","author":"Reddy TA","year":"2006","journal-title":"ASHRAE Trans"},{"key":"bibr5-0037549714528744","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2011.09.039"},{"key":"bibr6-0037549714528744","doi-asserted-by":"publisher","DOI":"10.1115\/1.2888069"},{"key":"bibr7-0037549714528744","first-page":"348","volume":"115","author":"Monfet D","year":"2009","journal-title":"ASHRAE Trans"},{"key":"bibr8-0037549714528744","unstructured":"Maile T, Fischer M, Bazjanac V. A method to compare measured and simulated data to assess building energy performance. Working paper #127, Center for Integrated Facility Engineering; Stanford, CA: Stanford University, 2010."},{"key":"bibr9-0037549714528744","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2011.09.001"},{"key":"bibr10-0037549714528744","doi-asserted-by":"publisher","DOI":"10.1016\/S0378-7788(00)00114-6"},{"key":"bibr11-0037549714528744","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijthermalsci.2003.06.001"},{"key":"bibr12-0037549714528744","unstructured":"National Renewable Energy Laboratory, U.S. Department of Energy. EnergyPlus Energy Simulation Software: OpenStudio Plug-in. Version 1.0.6, http:\/\/apps1.eere.energy.gov\/buildings\/energyplus\/openstudio.cfm (accessed October 2010)."},{"key":"bibr13-0037549714528744","unstructured":"Google, Inc. Google SketchUp Pro. Version 8, http:\/\/sketchup.google.com (accessed October 2010)."},{"key":"bibr14-0037549714528744","first-page":"721","volume":"105","author":"Judkoff R","year":"1999","journal-title":"ASHRAE Trans"},{"key":"bibr15-0037549714528744","doi-asserted-by":"publisher","DOI":"10.2172\/90674"},{"key":"bibr16-0037549714528744","author":"Standard method of test for the evaluation of building energy analysis computer programs","year":"2007","journal-title":"American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA"},{"key":"bibr17-0037549714528744","unstructured":"United States Department of Energy. Building Technologies Office: EnergyPlus Energy Simulation Software, http:\/\/apps1.eere.energy.gov\/buildings\/energyplus\/ (accessed 24 February 2012)."},{"key":"bibr18-0037549714528744","unstructured":"Henninger RH, Witte MJ. EnergyPlus testing with building thermal envelope and fabric load tests from ANSI\/ASHRAE Standard 140-2007, EnergyPlus Version 7.0.0.036. United States Department of Energy, http:\/\/apps1.eere.energy.gov\/buildings\/energyplus\/pdfs\/archived_testing_reports\/energyplus_7.0.0.036_testing_reports.zip (2011, accessed 26 December 2012)."},{"key":"bibr19-0037549714528744","unstructured":"Maile T, Fischer M, Haymaker J, Bazjanac V. Formalizing approximations, assumptions, and simplifications to document limitations in building energy performance simulation. Working paper #126, Center for Integrated Facility Engineering; Stanford, CA: Stanford University, 2010."},{"key":"bibr20-0037549714528744","unstructured":"California Energy Commission. Residential Manual for Compliance with California\u2019s 1998 Energy Efficiency Standards, http:\/\/www.energy.ca.gov\/title24\/archive\/1998standards\/residential_manual\/index.html (accessed February 2012)."},{"key":"bibr21-0037549714528744","unstructured":"Weather Underground. History for Sacramento International, CA,http:\/\/www.wunderground.com\/history\/airport\/KSMF\/2012\/2\/9\/DailyHistory.html (accessed March 2012)."},{"key":"bibr22-0037549714528744","unstructured":"National Renewable Energy Laboratory, US Department of Energy. NREL: MIDC\/SMUD Anatolia Rotating Shadowband Radiometer, http:\/\/www.nrel.gov\/midc\/smud_anatolia\/ (accessed March 2012)."},{"key":"bibr23-0037549714528744","volume-title":"Computerized building energy simulation handbook","author":"Waltz JP","year":"2000"},{"key":"bibr24-0037549714528744","first-page":"461","author":"McCray JA","year":"1995","journal-title":"proceedings of building simulation"},{"key":"bibr25-0037549714528744","doi-asserted-by":"publisher","DOI":"10.1080\/10789669.2007.10390952"},{"key":"bibr26-0037549714528744","unstructured":"Measurement of Energy and Demand Savings. ASHRAE Guideline 14-2002. Atlanta, GA: American Society of Heating, Refrigerating and Air-Conditioning Engineers, 2002."},{"key":"bibr27-0037549714528744","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2011.05.020"},{"key":"bibr28-0037549714528744","volume-title":"The design of energy-responsive commercial buildings","author":"Ternoey SE","year":"1985"},{"key":"bibr29-0037549714528744","unstructured":"2009 ASHRAE Handbook \u2013 Fundamentals (SI Edition). American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 2009."},{"key":"bibr30-0037549714528744","unstructured":"2008 Building Energy Efficiency Standards \u2013 Residential Compliance Manual. CEC-400-2008-016-CMF-Rev I. California Energy Commission, 2010."},{"key":"bibr31-0037549714528744","doi-asserted-by":"publisher","DOI":"10.1016\/0038-092X(82)90302-4"}],"container-title":["SIMULATION"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0037549714528744","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0037549714528744","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0037549714528744","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T11:25:21Z","timestamp":1777634721000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0037549714528744"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,4,15]]},"references-count":31,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2014,8]]}},"alternative-id":["10.1177\/0037549714528744"],"URL":"https:\/\/doi.org\/10.1177\/0037549714528744","relation":{},"ISSN":["0037-5497","1741-3133"],"issn-type":[{"value":"0037-5497","type":"print"},{"value":"1741-3133","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,4,15]]}}}