{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T21:33:48Z","timestamp":1781127228607,"version":"3.54.1"},"reference-count":37,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2017,5,3]],"date-time":"2017-05-03T00:00:00Z","timestamp":1493769600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"name":"Shanghai International Science and Technology Cooperation Project","award":["15220710700"],"award-info":[{"award-number":["15220710700"]}]},{"DOI":"10.13039\/501100012226","name":"Fundamental Research Funds for the Central Universities","doi-asserted-by":"crossref","award":["2016ZZD03"],"award-info":[{"award-number":["2016ZZD03"]}],"id":[{"id":"10.13039\/501100012226","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61304041, 61272064, 61673178"],"award-info":[{"award-number":["61304041, 61272064, 61673178"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Transactions of the Institute of Measurement and Control"],"published-print":{"date-parts":[[2019,4]]},"abstract":"<jats:p>The performance optimization of the load frequency control problem for two-area interconnected power system is investigated by employing the gravitational search algorithm based linear active disturbance rejection control approach. Firstly, the load frequency control problem of a two-area power system with two identical non-reheated turbine units is formulated, taking into account the external step disturbance and parameters perturbation. Then, the essentials of the second order process oriented linear active disturbance rejection control approach are presented, where the parameters optimization procedure based on the gravitation search algorithm is proposed. Finally, the effectiveness of the proposed approach in the load frequency control problem is validated by the given extensive simulation examples. The disturbance rejection ability and the robustness with respect to the parameter perturbation of the proposed approach are also demonstrated.<\/jats:p>","DOI":"10.1177\/0142331217701539","type":"journal-article","created":{"date-parts":[[2017,5,3]],"date-time":"2017-05-03T14:08:21Z","timestamp":1493820501000},"page":"1562-1570","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":31,"title":["Linear active disturbance rejection control approach for load frequency control of two-area interconnected power system"],"prefix":"10.1177","volume":"41","author":[{"given":"Congzhi","family":"Huang","sequence":"first","affiliation":[{"name":"School of Control and Computer Engineering, North China Electric Power University, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Li","sequence":"additional","affiliation":[{"name":"School of Control and Computer Engineering, North China Electric Power University, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shicai","family":"Mu","sequence":"additional","affiliation":[{"name":"School of Control and Computer Engineering, North China Electric Power University, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huaicheng","family":"Yan","sequence":"additional","affiliation":[{"name":"Key Laboratory of Advanced Control and Optimization for Chemical Processes of Ministry of Education, School of Information Science and Engineering, East China University of Science and Technology, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2017,5,3]]},"reference":[{"key":"bibr1-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2010.12.022"},{"key":"bibr2-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1049\/iet-cta.2015.0412"},{"key":"bibr3-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1109\/ICCPCT.2016.7530205"},{"key":"bibr4-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.isatra.2012.02.004"},{"key":"bibr5-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1109\/INISTA.2012.6246992"},{"key":"bibr6-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2015.2412614"},{"key":"bibr7-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2014.12.012"},{"key":"bibr8-0142331217701539","first-page":"4989","volume-title":"Proceedings of American Control Conference","author":"Gao ZQ","year":"2003"},{"key":"bibr9-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1049\/iet-pel.2015.0144"},{"key":"bibr10-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2008.2011621"},{"key":"bibr11-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1080\/00207179.2015.1050699"},{"key":"bibr12-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.automatica.2015.12.026"},{"key":"bibr13-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1109\/TCST.2016.2536708"},{"key":"bibr14-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1109\/TCYB.2015.2411285"},{"key":"bibr15-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.2015.2429555"},{"issue":"1","key":"bibr16-0142331217701539","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1109\/TPWRS.2004.841223","volume":"20","author":"Ibrabeem PK","year":"2005","journal-title":"IEEE Transactions on Power Systems"},{"key":"bibr17-0142331217701539","volume-title":"Power System Stability and Control","author":"Kundur P","year":"1994"},{"key":"bibr18-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.egypro.2011.12.1210"},{"key":"bibr19-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1177\/0142331213519815"},{"key":"bibr20-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1177\/0142331214543295"},{"key":"bibr21-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2015.06.013"},{"key":"bibr22-0142331217701539","doi-asserted-by":"publisher","DOI":"10.15676\/ijeei.2013.5.3.8"},{"key":"bibr23-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.isatra.2012.10.003"},{"key":"bibr24-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2013.04.029"},{"key":"bibr25-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1177\/0142331214561917"},{"key":"bibr26-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2015.2462746"},{"key":"bibr27-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.ins.2009.03.004"},{"key":"bibr28-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.engappai.2010.05.007"},{"key":"bibr29-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.enconman.2008.09.014"},{"key":"bibr30-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2015.07.020"},{"key":"bibr31-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2011.12.005"},{"key":"bibr32-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.neucom.2016.01.066"},{"key":"bibr33-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.enconman.2015.02.005"},{"key":"bibr34-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1002\/asjc.240"},{"key":"bibr35-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.isatra.2015.05.001"},{"key":"bibr36-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2016.2559454"},{"key":"bibr37-0142331217701539","doi-asserted-by":"publisher","DOI":"10.1016\/j.nahs.2016.03.006"}],"container-title":["Transactions of the Institute of Measurement and Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0142331217701539","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0142331217701539","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0142331217701539","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T14:55:22Z","timestamp":1777647322000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0142331217701539"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5,3]]},"references-count":37,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019,4]]}},"alternative-id":["10.1177\/0142331217701539"],"URL":"https:\/\/doi.org\/10.1177\/0142331217701539","relation":{},"ISSN":["0142-3312","1477-0369"],"issn-type":[{"value":"0142-3312","type":"print"},{"value":"1477-0369","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,5,3]]}}}