{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,28]],"date-time":"2026-01-28T12:59:18Z","timestamp":1769605158570,"version":"3.49.0"},"reference-count":46,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2018,3,26]],"date-time":"2018-03-26T00:00:00Z","timestamp":1522022400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Transactions of the Institute of Measurement and Control"],"published-print":{"date-parts":[[2019,4]]},"abstract":"<jats:p> Organic Rankine cycle (ORC) is one of the most rapidly growing approaches to utilizing low grade thermal energy. This paper deals with the main control problems existed in ORC systems and overviews the main approaches presented in literature. The main ORC operating modes are introduced, the control strategies of ORC systems are then surveyed. Thus, this paper presents a comprehensive review of overall control strategies for ORC energy conversion systems and points out research trend on ORC control systems. <\/jats:p>","DOI":"10.1177\/0142331217753061","type":"journal-article","created":{"date-parts":[[2018,3,26]],"date-time":"2018-03-26T10:54:43Z","timestamp":1522061683000},"page":"1528-1539","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":22,"title":["Recent developments of control strategies for organic Rankine cycle (ORC) systems"],"prefix":"10.1177","volume":"41","author":[{"given":"Jianhua","family":"Zhang","sequence":"first","affiliation":[{"name":"State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, China"}]},{"given":"Kang","family":"Li","sequence":"additional","affiliation":[{"name":"School of Electronics, Electrical Engineering and Computer Science Queen\u2019s University Belfast, UK"}]},{"given":"Jinliang","family":"Xu","sequence":"additional","affiliation":[{"name":"The Beijing Key Laboratory of New and Renewable Energy, North China Electric Power University, China"}]}],"member":"179","published-online":{"date-parts":[[2018,3,26]]},"reference":[{"key":"bibr1-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2013.03.040"},{"key":"bibr2-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1115\/1.4029884"},{"key":"bibr3-0142331217753061","doi-asserted-by":"publisher","DOI":"10.3390\/en7106571"},{"key":"bibr4-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/CDC.2015.7402105"},{"key":"bibr5-0142331217753061","doi-asserted-by":"publisher","DOI":"10.3182\/20140824-6-ZA-1003.01796"},{"key":"bibr6-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/ECC.2015.7330874"},{"key":"bibr7-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.enconman.2014.06.004"},{"key":"bibr8-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-5442(96)00165-X"},{"key":"bibr9-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2015.03.089"},{"key":"bibr10-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/TCST.2014.2381157"},{"key":"bibr11-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/ACC.2014.6858907"},{"key":"bibr12-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/ACC.2014.6858907"},{"key":"bibr13-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1115\/DSCC2015-9707"},{"issue":"47","key":"bibr14-0142331217753061","first-page":"1","volume":"3","author":"Markides CN","year":"2015","journal-title":"Frontiers in Energy Research"},{"key":"bibr15-0142331217753061","doi-asserted-by":"publisher","DOI":"10.3182\/20120328-3-IT-3014.00078"},{"key":"bibr16-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/CDC.2014.7039902"},{"key":"bibr17-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/TCST.2016.2574760"},{"key":"bibr18-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/CDC.2013.6760971"},{"key":"bibr19-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.jprocont.2015.03.009"},{"key":"bibr20-0142331217753061","doi-asserted-by":"publisher","DOI":"10.3182\/20140824-6-ZA-1003.02185"},{"issue":"10","key":"bibr21-0142331217753061","first-page":"6","author":"Qiu LL","year":"2015","journal-title":"Applied Energy Technology"},{"key":"bibr22-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.apenergy.2011.01.015"},{"key":"bibr23-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2013.01.028"},{"key":"bibr24-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/ECC.2015.7330920"},{"key":"bibr25-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/CONTROL.2016.7737554"},{"key":"bibr26-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.energy.2016.02.065"},{"key":"bibr27-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1002\/9781119283362.ch3"},{"key":"bibr28-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.applthermaleng.2012.10.017"},{"key":"bibr29-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2011.07.024"},{"key":"bibr30-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/ICM.2013.6735014"},{"key":"bibr31-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.ifacol.2015.10.060"},{"key":"bibr32-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.enconman.2016.07.078"},{"key":"bibr33-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.applthermaleng.2016.09.021"},{"key":"bibr34-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2012.03.022"},{"key":"bibr35-0142331217753061","doi-asserted-by":"publisher","DOI":"10.3390\/en5125111"},{"key":"bibr36-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/ICIEA.2013.6566345"},{"key":"bibr37-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.energy.2017.01.131"},{"key":"bibr38-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.energy.2016.04.064"},{"key":"bibr39-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1007\/s11434-014-0590-1"},{"key":"bibr40-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/WCICA.2016.7578809"},{"key":"bibr41-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/WCICA.2014.7052793"},{"key":"bibr42-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.camwa.2012.01.054"},{"key":"bibr43-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1109\/CONTROL.2016.7737577"},{"key":"bibr44-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.apenergy.2012.07.038"},{"key":"bibr45-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.energy.2014.01.068"},{"key":"bibr46-0142331217753061","doi-asserted-by":"publisher","DOI":"10.1016\/j.apenergy.2014.01.074"}],"container-title":["Transactions of the Institute of Measurement and Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0142331217753061","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0142331217753061","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0142331217753061","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,28]],"date-time":"2025-02-28T18:58:09Z","timestamp":1740769089000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0142331217753061"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3,26]]},"references-count":46,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019,4]]}},"alternative-id":["10.1177\/0142331217753061"],"URL":"https:\/\/doi.org\/10.1177\/0142331217753061","relation":{},"ISSN":["0142-3312","1477-0369"],"issn-type":[{"value":"0142-3312","type":"print"},{"value":"1477-0369","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3,26]]}}}