{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T16:00:44Z","timestamp":1777910444012,"version":"3.51.4"},"reference-count":36,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2018,7,23]],"date-time":"2018-07-23T00:00:00Z","timestamp":1532304000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Transactions of the Institute of Measurement and Control"],"published-print":{"date-parts":[[2019,2]]},"abstract":"<jats:p>In this paper, an adaptive proportional-integral controller based on a fuzzy relational model is developed for the purpose of fault tolerant control in a nonlinear, information-poor system. First, the methods of fault tolerant control are briefly introduced. An air-cooling subsystem in a heating, ventilating and air-conditioning system is used as an example to describe the fuzzy relational modelling procedure. Then a proportional-integral (PI) observer is established for fault identification and a PI-based adaptive controller is designed for fault tolerance with varied parameter adjusting. By introducing the fault estimation, an adaptive mechanism is adopted to update the parameter selection in the control scheme. Sensor noise is also considered in the method and simulation experiments are performed to verify the effectiveness of the proposed scheme.<\/jats:p>","DOI":"10.1177\/0142331218781704","type":"journal-article","created":{"date-parts":[[2018,7,23]],"date-time":"2018-07-23T09:00:46Z","timestamp":1532336446000},"page":"1088-1100","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":3,"title":["An adaptive fault tolerant neuro-fuzzy based proportional-integral controller for a nonlinear system"],"prefix":"10.1177","volume":"41","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2337-776X","authenticated-orcid":false,"given":"Yimin","family":"Zhou","sequence":"first","affiliation":[{"name":"Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2018,7,23]]},"reference":[{"key":"bibr1-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1016\/j.isatra.2017.03.016"},{"key":"bibr2-0142331218781704","first-page":"1","volume":"2","author":"Azmi H","year":"2017","journal-title":"International Journal of Adaptive Control & Signal Processing"},{"key":"bibr3-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1109\/SYSTOL.2010.5675967"},{"key":"bibr4-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1002\/rnc.1807"},{"issue":"5","key":"bibr5-0142331218781704","first-page":"7","volume":"12","author":"Chen C","year":"2015","journal-title":"Acta Polytechnica Hungarica"},{"key":"bibr6-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1016\/S0165-0114(99)00173-6"},{"issue":"1","key":"bibr7-0142331218781704","first-page":"49","volume":"11","author":"Farhani F","year":"2014","journal-title":"Ada Polytechnica Hungarica"},{"key":"bibr8-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1016\/0005-1098(90)90018-D"},{"key":"bibr9-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2015.2417501"},{"key":"bibr10-0142331218781704","volume-title":"SIMBAD Building and HVAC Toolbox, Version 3.0","author":"Husaunndee A","year":"2001"},{"key":"bibr11-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1109\/ISIE.2004.1571791"},{"key":"bibr12-0142331218781704","doi-asserted-by":"publisher","DOI":"10.3182\/20120829-3-MX-2028.00069"},{"key":"bibr13-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1016\/j.automatica.2016.02.014"},{"key":"bibr14-0142331218781704","volume-title":"Theory and Practice of Recursive Identification","author":"Ljung L","year":"1983"},{"key":"bibr15-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1016\/j.isatra.2015.02.004"},{"issue":"3","key":"bibr16-0142331218781704","doi-asserted-by":"crossref","first-page":"181","DOI":"10.12700\/APH.13.3.2016.3.10","volume":"13","author":"Natarajan M","year":"2016","journal-title":"Acta Polytechnica Hungarica"},{"key":"bibr17-0142331218781704","first-page":"446","volume-title":"Proceedings of the 5th international conference on system simulation in buildings","author":"Ngo D","year":"1998"},{"key":"bibr18-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1016\/j.automatica.2017.03.014"},{"key":"bibr19-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4471-3644-6"},{"key":"bibr20-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1049\/ip-cta:19984437"},{"key":"bibr21-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1109\/MED.2014.6961382"},{"key":"bibr22-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1016\/j.renene.2014.10.061"},{"key":"bibr23-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfranklin.2014.03.016"},{"key":"bibr24-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1109\/ECAI.2014.7090193"},{"key":"bibr25-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1109\/MED.2017.7984157"},{"key":"bibr26-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.2016.2564921"},{"key":"bibr27-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1109\/CCDC.2017.7978514"},{"key":"bibr28-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1016\/j.automatica.2017.07.037"},{"key":"bibr29-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2014.06.042"},{"key":"bibr30-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1016\/j.renene.2015.08.028"},{"key":"bibr31-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1109\/CCDC.2017.7978243"},{"key":"bibr32-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfranklin.2016.06.038"},{"key":"bibr33-0142331218781704","volume-title":"Fault identification in nonlinear dynmaic systems","author":"Zhou Y","year":"2008"},{"key":"bibr34-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1109\/ROBIO.2015.7419697"},{"key":"bibr35-0142331218781704","doi-asserted-by":"publisher","DOI":"10.1080\/10789669.2009.10390830"},{"key":"bibr36-0142331218781704","volume-title":"Robust and Optimal Control","author":"Zhou K","year":"1996"}],"container-title":["Transactions of the Institute of Measurement and Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0142331218781704","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0142331218781704","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0142331218781704","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T14:57:44Z","timestamp":1777647464000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0142331218781704"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,23]]},"references-count":36,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,2]]}},"alternative-id":["10.1177\/0142331218781704"],"URL":"https:\/\/doi.org\/10.1177\/0142331218781704","relation":{},"ISSN":["0142-3312","1477-0369"],"issn-type":[{"value":"0142-3312","type":"print"},{"value":"1477-0369","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,7,23]]}}}