{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,2]],"date-time":"2025-11-02T20:02:24Z","timestamp":1762113744962,"version":"3.38.0"},"reference-count":29,"publisher":"SAGE Publications","issue":"10","license":[{"start":{"date-parts":[[2018,11,26]],"date-time":"2018-11-26T00:00:00Z","timestamp":1543190400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"name":"Natural Science Foundation of Science and Technology Department of Hubei province","award":["2015GA013"],"award-info":[{"award-number":["2015GA013"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["11402180"],"award-info":[{"award-number":["11402180"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Transactions of the Institute of Measurement and Control"],"published-print":{"date-parts":[[2019,6]]},"abstract":"<jats:p> In order to monitor the combustion condition and improve the product material quality, a digital image acquisition and processing method is adopted in alumina-sintering process. Two digital properties of flame grade and material grade are obtained by image data analyzing and smooth filtering, which provide reliable reference for operational optimization and automatic control of rotary kilns. This image acquisition system improves the operation of kiln effectively and reduces the working intensity and the manufacture cost. <\/jats:p>","DOI":"10.1177\/0142331218810085","type":"journal-article","created":{"date-parts":[[2018,11,26]],"date-time":"2018-11-26T10:42:55Z","timestamp":1543228975000},"page":"2764-2771","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":4,"title":["An alumina rotary kiln monitoring system based on flame image processing"],"prefix":"10.1177","volume":"41","author":[{"given":"Chaoqun","family":"Lin","sequence":"first","affiliation":[{"name":"State Key Laboratory of Refractories and Metallurgy, Wuhan University of Science and Technology, China"},{"name":"Higher Education Research Institute, Wuhan University of Science and Technology, China"}]},{"given":"Zhengming","family":"Yi","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Refractories and Metallurgy, Wuhan University of Science and Technology, China"},{"name":"National-provincial Joint Engineering Research Center of High Temperature Materials and Lining Technology, Wuhan University of Science and Technology, China"}]},{"given":"Zhiwei","family":"Jiang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Refractories and Metallurgy, Wuhan University of Science and Technology, China"}]}],"member":"179","published-online":{"date-parts":[[2018,11,26]]},"reference":[{"key":"bibr1-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1177\/0142331207070362"},{"key":"bibr2-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1016\/j.applthermaleng.2011.04.024"},{"key":"bibr3-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2017.2683480"},{"key":"bibr4-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2005.846856"},{"key":"bibr5-0142331218810085","first-page":"2568","volume-title":"IEEE 10th International Conference on Signal Processing Proceedings","author":"Guo F","year":"2010"},{"issue":"3","key":"bibr6-0142331218810085","first-page":"803","volume":"20","author":"Jiang HY","year":"2008","journal-title":"Journal of System Simulation"},{"key":"bibr7-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1109\/TII.2012.2189224"},{"key":"bibr8-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1016\/j.neucom.2011.12.047"},{"key":"bibr9-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1016\/j.powtec.2015.10.007"},{"key":"bibr10-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1016\/j.powtec.2014.08.076"},{"key":"bibr11-0142331218810085","first-page":"418","volume-title":"37th Intersociety Energy Conversion Engineering Conference","author":"Ma AC","year":"2002"},{"key":"bibr12-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2011.09.013"},{"key":"bibr13-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1016\/j.expthermflusci.2015.08.017"},{"key":"bibr14-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1016\/j.patcog.2008.09.033"},{"key":"bibr15-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1016\/j.conengprac.2010.08.004"},{"key":"bibr16-0142331218810085","first-page":"7615","volume-title":"7th World Congress on Intelligent Control and Automation","author":"Sun P","year":"2008"},{"key":"bibr17-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1177\/0142331215573099"},{"key":"bibr18-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1177\/0142331217716983."},{"key":"bibr19-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1109\/ICIEA.2014.6931402"},{"key":"bibr20-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1007\/s11771-012-1114-2"},{"key":"bibr21-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1109\/TFUZZ.2008.928601"},{"key":"bibr22-0142331218810085","doi-asserted-by":"publisher","DOI":"10.14257\/ijmue.2015.10.2.08"},{"key":"bibr23-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1177\/0142331217737834."},{"issue":"2","key":"bibr24-0142331218810085","first-page":"357","volume":"7997","author":"Yang BS","year":"2011","journal-title":"Proc Spie"},{"key":"bibr25-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1016\/j.measurement.2013.03.030"},{"key":"bibr26-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1007\/s11771-013-1796-0"},{"key":"bibr27-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1007\/s11771-008-0009-8"},{"key":"bibr28-0142331218810085","doi-asserted-by":"publisher","DOI":"10.1016\/S1006-706X(13)60135-1"},{"key":"bibr29-0142331218810085","doi-asserted-by":"publisher","DOI":"10.4028\/www.scientific.net\/AMM.385-386.848"}],"container-title":["Transactions of the Institute of Measurement and Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0142331218810085","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0142331218810085","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0142331218810085","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,1]],"date-time":"2025-03-01T02:29:06Z","timestamp":1740796146000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0142331218810085"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,26]]},"references-count":29,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2019,6]]}},"alternative-id":["10.1177\/0142331218810085"],"URL":"https:\/\/doi.org\/10.1177\/0142331218810085","relation":{},"ISSN":["0142-3312","1477-0369"],"issn-type":[{"type":"print","value":"0142-3312"},{"type":"electronic","value":"1477-0369"}],"subject":[],"published":{"date-parts":[[2018,11,26]]}}}