{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,1]],"date-time":"2025-03-01T05:39:16Z","timestamp":1740807556022,"version":"3.38.0"},"reference-count":33,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2019,11,6]],"date-time":"2019-11-06T00:00:00Z","timestamp":1572998400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Transactions of the Institute of Measurement and Control"],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:p> For intermittent transonic wind tunnel (ITWT), Mach number and total pressure are crucial features of the flow field in the test section. However, they are typically difficult to control due to system nonlinearities, uncertainties, coupling and delays. This paper proposes an output feedback model predictive control (MPC) strategy to ensure the tracking of Mach number and total pressure of the ITWT to a specified reference trajectory. The proposed approach includes open-loop prediction, steady state target calculation (SSTC) and dynamic control, where the lower layer dynamic control tracks the steady state target obtained from the upper SSTC layer. By adding an artificial disturbance in the identified linear parameter varying (LPV) model for ITWT, and utilizing the resulting LPV model in both SSTC and dynamic control layers, a heuristic open-loop output feedback MPC approach is proposed. The experimental results for the control of Mach number and total pressure for ITWT demonstrate the effectiveness of the proposed approach. <\/jats:p>","DOI":"10.1177\/0142331219879857","type":"journal-article","created":{"date-parts":[[2019,11,6]],"date-time":"2019-11-06T09:56:31Z","timestamp":1573034191000},"page":"832-839","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Heuristic open-loop output feedback model predictive control for control of intermittent transonic wind tunnel"],"prefix":"10.1177","volume":"42","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4143-9955","authenticated-orcid":false,"given":"Jianchen","family":"Hu","sequence":"first","affiliation":[{"name":"Department of Automation, School of Electronic and Information Engineering, Xi\u2019an Jiaotong University, China"}]},{"given":"Baocang","family":"Ding","sequence":"additional","affiliation":[{"name":"College of Automation, Chongqing University of Posts and Telecommunications, China"}]}],"member":"179","published-online":{"date-parts":[[2019,11,6]]},"reference":[{"key":"bibr1-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1002\/rnc.706"},{"key":"bibr2-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1109\/TAC.2012.2187400"},{"key":"bibr3-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1021\/ie034320d"},{"key":"bibr4-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/j.sysconle.2012.01.003"},{"key":"bibr5-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/j.automatica.2013.02.060"},{"key":"bibr6-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1109\/TAC.2002.800662"},{"key":"bibr7-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/j.automatica.2014.10.021"},{"key":"bibr8-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/j.jprocont.2013.12.006"},{"issue":"4","key":"bibr9-0142331219879857","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/asjc.1641","volume":"20","author":"Ding B","year":"2018","journal-title":"Asian Journal of Control"},{"key":"bibr10-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1109\/TCST.2008.2005487"},{"key":"bibr11-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1109\/TAC.2012.2186163"},{"key":"bibr12-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfranklin.2014.03.006"},{"issue":"1013","key":"bibr13-0142331219879857","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1017\/S0001924000065441","volume":"102","author":"Hwang DS","year":"1998","journal-title":"Aeronaut Journal"},{"key":"bibr14-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/j.jprocont.2010.11.008"},{"key":"bibr15-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/0005-1098(96)00063-5"},{"key":"bibr16-0142331219879857","first-page":"87324","author":"Krosel S","year":"1986","journal-title":"Paper"},{"key":"bibr17-0142331219879857","doi-asserted-by":"publisher","DOI":"10.3182\/20120711-3-BE-2027.00230"},{"key":"bibr18-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/j.automatica.2013.01.010"},{"issue":"2","key":"bibr19-0142331219879857","first-page":"239","volume":"32","author":"Li S","year":"2015","journal-title":"Control Theory & Applications"},{"key":"bibr20-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2013.2262077"},{"key":"bibr21-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1109\/TAC.1984.1103436"},{"key":"bibr22-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/S0005-1098(99)00214-9"},{"key":"bibr23-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/S0098-1354(98)00301-9"},{"key":"bibr24-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1007\/s10489-007-0082-y"},{"key":"bibr25-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/j.automatica.2011.06.015"},{"issue":"1","key":"bibr26-0142331219879857","first-page":"25","volume":"30","author":"Pela AF","year":"1989","journal-title":"AIAA Journal"},{"key":"bibr27-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/S0019-0578(07)60050-0"},{"key":"bibr28-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/S0959-1524(02)00133-6"},{"key":"bibr29-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/j.jprocont.2009.11.010"},{"key":"bibr30-0142331219879857","first-page":"203","volume-title":"Proceedings of the 1997 American Control Conference","author":"Zhang G","year":"1997"},{"key":"bibr31-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1109\/TAES.2017.2756538"},{"key":"bibr32-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1016\/j.automatica.2013.09.024"},{"key":"bibr33-0142331219879857","doi-asserted-by":"publisher","DOI":"10.1177\/0142331217728569"}],"container-title":["Transactions of the Institute of Measurement and Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0142331219879857","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0142331219879857","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0142331219879857","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,28]],"date-time":"2025-02-28T15:47:50Z","timestamp":1740757670000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0142331219879857"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,6]]},"references-count":33,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["10.1177\/0142331219879857"],"URL":"https:\/\/doi.org\/10.1177\/0142331219879857","relation":{},"ISSN":["0142-3312","1477-0369"],"issn-type":[{"type":"print","value":"0142-3312"},{"type":"electronic","value":"1477-0369"}],"subject":[],"published":{"date-parts":[[2019,11,6]]}}}