{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T16:09:21Z","timestamp":1777910961596,"version":"3.51.4"},"reference-count":27,"publisher":"SAGE Publications","issue":"9","license":[{"start":{"date-parts":[[2024,8,24]],"date-time":"2024-08-24T00:00:00Z","timestamp":1724457600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["52107075"],"award-info":[{"award-number":["52107075"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Transactions of the Institute of Measurement and Control"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:p>This paper considers the distributed secondary control for direct current (DC) microgrid to regulate the DC bus voltage containing local loads. An adaptive event-triggered protocol is employed to update the control input to save transmission energy and ensure the control performance. Depending on the switch of the converter, a switching dynamical equation is proposed to describe a microgrid with a DC\u2013DC boost converter. Moreover, the Lyapunov technique is developed to assure the stability of the system, which effectively handles real-time precision of input and model uncertainties. Combining this method with proportionate load sharing enables global average voltage management and the system performance preservation in DC microgrids for a variety of disturbances. Finally, the effectiveness of the proposed method is verified by simulation.<\/jats:p>","DOI":"10.1177\/01423312241266007","type":"journal-article","created":{"date-parts":[[2024,8,24]],"date-time":"2024-08-24T07:36:48Z","timestamp":1724485008000},"page":"1771-1782","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":2,"title":["Distributed secondary control for DC microgrid under the adaptive event-triggered protocol"],"prefix":"10.1177","volume":"47","author":[{"given":"Dianjun","family":"Chen","sequence":"first","affiliation":[{"name":"Heilongjiang Power Company of State Grid, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xueshen","family":"Wang","sequence":"additional","affiliation":[{"name":"Heilongjiang Power Company of State Grid, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ran","family":"Sun","sequence":"additional","affiliation":[{"name":"Heilongjiang Power Company of State Grid, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruizhi","family":"Zhang","sequence":"additional","affiliation":[{"name":"State Grid Heilongjiang Electric Power Supply Company Limited Economic Research Institute, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shaoshu","family":"Zhu","sequence":"additional","affiliation":[{"name":"Harbin Huaqiang Power Automation Engineering Company, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jingyuan","family":"Chen","sequence":"additional","affiliation":[{"name":"Harbin Hongyuanda Technology Development Co., Ltd, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0702-8295","authenticated-orcid":false,"given":"Mingfei","family":"Ban","sequence":"additional","affiliation":[{"name":"College of Mechanical and Electrical Engineering, Northeast Forestry University, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2024,8,24]]},"reference":[{"key":"e_1_3_2_2_1","doi-asserted-by":"publisher","DOI":"10.1049\/iet-pel.2018.5767"},{"key":"e_1_3_2_3_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2017.2679238"},{"key":"e_1_3_2_4_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2013.2247071"},{"key":"e_1_3_2_5_1","doi-asserted-by":"publisher","DOI":"10.1109\/TII.2017.2784561"},{"key":"e_1_3_2_6_1","doi-asserted-by":"publisher","DOI":"10.1109\/MCOM.2012.6257523"},{"key":"e_1_3_2_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.renene.2019.08.092"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1109\/SURV.2011.101911.00087"},{"key":"e_1_3_2_9_1","doi-asserted-by":"publisher","DOI":"10.1109\/JETCAS.2020.3046781"},{"key":"e_1_3_2_10_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSTE.2022.3176741"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2020.110120"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2012.2204410"},{"key":"e_1_3_2_13_1","doi-asserted-by":"publisher","DOI":"10.1109\/JSYST.2014.2345911"},{"key":"e_1_3_2_14_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSIPN.2020.3012254"},{"key":"e_1_3_2_15_1","volume-title":"Low Gain Feedback","author":"Lin Z","year":"1998","unstructured":"Lin Z (1998) Low Gain Feedback. London: Springer-Verlag."},{"key":"e_1_3_2_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/SURV.2011.122111.00145"},{"key":"e_1_3_2_17_1","doi-asserted-by":"publisher","DOI":"10.1049\/cth2.12124"},{"key":"e_1_3_2_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2022.108171"},{"key":"e_1_3_2_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2020.106757"},{"key":"e_1_3_2_20_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.2018.2884952"},{"key":"e_1_3_2_21_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2021.3136679"},{"key":"e_1_3_2_22_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00521-022-07123-6"},{"issue":"6","key":"e_1_3_2_23_1","first-page":"2176","article-title":"Finite-time synchronization and energy consumption prediction for multilayer fractional-order networks","volume":"70","author":"Tong D","year":"2023","unstructured":"Tong D, Ma B, Chen Q, et al. (2023) Finite-time synchronization and energy consumption prediction for multilayer fractional-order networks. IEEE Transactions on Circuits and Systems II: Express Briefs 70(6): 2176\u20132180.","journal-title":"IEEE Transactions on Circuits and Systems II: Express Briefs"},{"key":"e_1_3_2_24_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.2022.3176460"},{"key":"e_1_3_2_25_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2013.2269481"},{"key":"e_1_3_2_26_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.2019.2916152"},{"issue":"4","key":"e_1_3_2_27_1","first-page":"1555","article-title":"Fixed-time synchronization and energy consumption for Kuramoto-oscillator networks with multilayer distributed control","volume":"70","author":"Yang G","year":"2023","unstructured":"Yang G, Tong D, Chen Q, et al. (2023) Fixed-time synchronization and energy consumption for Kuramoto-oscillator networks with multilayer distributed control. IEEE Transactions on Circuits and Systems II: Express Briefs 70(4): 1555\u20131559.","journal-title":"IEEE Transactions on Circuits and Systems II: Express Briefs"},{"key":"e_1_3_2_28_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2021.3128899"}],"container-title":["Transactions of the Institute of Measurement and Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/01423312241266007","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/01423312241266007","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/01423312241266007","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T15:11:17Z","timestamp":1777648277000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/01423312241266007"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,24]]},"references-count":27,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["10.1177\/01423312241266007"],"URL":"https:\/\/doi.org\/10.1177\/01423312241266007","relation":{},"ISSN":["0142-3312","1477-0369"],"issn-type":[{"value":"0142-3312","type":"print"},{"value":"1477-0369","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,24]]}}}