{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T11:05:58Z","timestamp":1771239958838,"version":"3.50.1"},"reference-count":26,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T00:00:00Z","timestamp":1733875200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Transactions of the Institute of Measurement and Control"],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:p>This study explores a method for detecting and isolating faults in wind power conversion systems that use a permanent magnet synchronous generator (PMSG). The goal is to enhance the reliability of the inverter by implementing an fault detection method and fault-tolerant control. The converter incorporates an extra leg with two switches that can be quickly connected in place of a malfunctioning leg, ensuring continued operation. Our fault detection and isolation module employs a threshold-based approach, utilizing real-time signal measurements to identify anomalies exceeding predefined limits. The experimental validation of this module is conducted on a high-performance dSpace DS1104 controller board using MATLAB Simulink. Finally, a real-world experiment was conducted to confirm the effectiveness of the proposed fault detection and isolation (FDI) algorithm. The results successfully demonstrated the algorithm\u2019s ability to detect and isolate switch faults.<\/jats:p>","DOI":"10.1177\/01423312241287263","type":"journal-article","created":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T05:17:58Z","timestamp":1733894278000},"page":"781-790","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Design and experimental validation of fault diagnosis and fault tolerant control in PMSG drives for wind energy conversion systems"],"prefix":"10.1177","volume":"48","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9136-4579","authenticated-orcid":false,"given":"Hedi","family":"Ben Mahdhi","sequence":"first","affiliation":[{"name":"Universit\u00e9 de Tunis, Ecole Nationale Sup\u00e9rieure d\u2019Ing\u00e9nieurs de Tunis (ENSIT), Tunis, Tunisia"},{"name":"Laboratoire de l\u2019Ing\u00e9nierie des Syst\u00e8mes Industriels et des Energies Renouvelables (LISIER)"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0519-5540","authenticated-orcid":false,"given":"Hechmi","family":"Ben Azza","sequence":"additional","affiliation":[{"name":"Universit\u00e9 de Tunis, Ecole Nationale Sup\u00e9rieure d\u2019Ing\u00e9nieurs de Tunis (ENSIT), Tunis, Tunisia"},{"name":"Laboratoire de l\u2019Ing\u00e9nierie des Syst\u00e8mes Industriels et des Energies Renouvelables (LISIER)"}]}],"member":"179","published-online":{"date-parts":[[2024,12,11]]},"reference":[{"key":"e_1_3_3_2_1","doi-asserted-by":"publisher","DOI":"10.48084\/etasr.6642"},{"key":"e_1_3_3_3_1","doi-asserted-by":"publisher","DOI":"10.3906\/elk-1805-149"},{"key":"e_1_3_3_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2012.03.024"},{"key":"e_1_3_3_5_1","volume-title":"Direct Power Control of a PMSG Dedicated to Standalone Wind Energy Systems","author":"Benatiallah A","year":"2013","unstructured":"Benatiallah A, Harrouz A, Harrouz O (2013). Direct Power Control of a PMSG Dedicated to Standalone Wind Energy Systems. Eighth International Conference and Exhibition on Ecological Vehicles and Renewable Energies (EVER), Monte Carlo."},{"key":"e_1_3_3_6_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2014.2373390"},{"key":"e_1_3_3_7_1","doi-asserted-by":"publisher","DOI":"10.1109\/JESTPE.2013.2275978"},{"issue":"3","key":"e_1_3_3_8_1","article-title":"Converter power loss analysis in a fault tolerant permanent-magnet synchronous motor drive","volume":"62","author":"Boccaletti C","year":"2015","unstructured":"Boccaletti C, Estima JO, Marques Cardoso AJ, et al. (2015). Converter power loss analysis in a fault tolerant permanent-magnet synchronous motor drive. IEEE Transactions on Industrial Electronics, 62(3).","journal-title":"IEEE Transactions on Industrial Electronics"},{"key":"e_1_3_3_9_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2010.2045322"},{"key":"e_1_3_3_10_1","first-page":"279","volume-title":"Proceedings of the IEEE WEMDCD","author":"Estima JO","year":"2013","unstructured":"Estima JO, Freire NM A, Cardoso AJM (2013). Recent advances in fault diagnosis by Park\u2019s vector approach. In Proceedings of the IEEE WEMDCD, Paris, France, 11\u201312; pp. 279\u2013288, March 2013."},{"key":"e_1_3_3_11_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2012.2188877"},{"key":"e_1_3_3_12_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2014.2330420"},{"key":"e_1_3_3_13_1","doi-asserted-by":"publisher","DOI":"10.1109\/JESTPE.2013.2295061"},{"key":"e_1_3_3_14_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2013.2251734"},{"key":"e_1_3_3_15_1","doi-asserted-by":"publisher","DOI":"10.1109\/ICMCS.2011.5945585"},{"key":"e_1_3_3_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2023.3239853"},{"key":"e_1_3_3_17_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2012.2212916"},{"key":"e_1_3_3_18_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2011.2162711"},{"key":"e_1_3_3_19_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2014.2347912"},{"issue":"4","key":"e_1_3_3_20_1","first-page":"8279","article-title":"Simulation study on permanent magnet wind power generation system based on PSIM","volume":"3","author":"Li N","year":"2014","unstructured":"Li N, Yu B, Liu L, et al. (2014). Simulation study on permanent magnet wind power generation system based on PSIM. International Journal of Advanced Research in Electrical. Electronics and Instrumentation Engineering, 3(4): 8279\u20138286.","journal-title":"International Journal of Advanced Research in Electrical. Electronics and Instrumentation Engineering"},{"key":"e_1_3_3_21_1","doi-asserted-by":"publisher","DOI":"10.48084\/etasr.6642"},{"key":"e_1_3_3_22_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2010.2095470"},{"key":"e_1_3_3_23_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2014.2375853"},{"key":"e_1_3_3_24_1","doi-asserted-by":"publisher","DOI":"10.6113\/JPE.2010.10.5.538"},{"key":"e_1_3_3_25_1","doi-asserted-by":"publisher","DOI":"10.1109\/IPEMC.2016.7512729"},{"key":"e_1_3_3_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2016.11.021"},{"key":"e_1_3_3_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2016.08.006"}],"container-title":["Transactions of the Institute of Measurement and Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/01423312241287263","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/01423312241287263","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/01423312241287263","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T10:12:38Z","timestamp":1771236758000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/01423312241287263"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,11]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["10.1177\/01423312241287263"],"URL":"https:\/\/doi.org\/10.1177\/01423312241287263","relation":{},"ISSN":["0142-3312","1477-0369"],"issn-type":[{"value":"0142-3312","type":"print"},{"value":"1477-0369","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,11]]}}}