{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,30]],"date-time":"2026-08-30T12:14:13Z","timestamp":1788092053634,"version":"build-2803163510"},"reference-count":11,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T00:00:00Z","timestamp":1787788800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Ann ICRP"],"abstract":"<jats:p>Imaging modalities such as on-board kilovoltage cone beam computed tomography (kV CBCT) on a linear accelerator (linac) are utilised daily to verify positioning in the multi-week fractionation schedule of a cancer patient undergoing treatment. There is a need for optimisation of radiological protection in kV CBCT imaging protocols to avoid unnecessarily high doses to normal tissues surrounding the target. Traditionally, a 100\u2005mm ionisation chamber and a cylindrical PMMA phantom are used in measuring CT doses, but these are not available in many radiotherapy centres. This study explores an alternative setup using a 0.6\u2005cc Farmer-type ionisation chamber and a 30\u2005cm\u2009\u00d7\u200930\u2005cm\u2009\u00d7\u200930\u2005cm cubically shaped phantom comprising slabs of water equivalent material typically used in radiotherapy centres. The weighted dose index values determined from the alternative setup are compared with those determined from the conventional cylindrical CT phantoms. The results indicate that the alternative setup using equipment more accessible in radiotherapy facilities is a viable alternative to the use of a CT phantom to quantify kV CBCT radiation dose from linac-based image-guided radiotherapy equipment that can be used for optimisation processes. This should allow most radiotherapy centres all over the world to engage in meaningful dose measurement and optimisation for CBCT.<\/jats:p>","DOI":"10.1177\/01466453251412497","type":"journal-article","created":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T15:02:07Z","timestamp":1787842927000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Development of a pragmatic methodology for measurement of dose for KV CBCT in radiotherapy: A pilot study"],"prefix":"10.1177","author":[{"given":"M.","family":"Djukelic","sequence":"first","affiliation":[{"name":"Sir Charles Gairdner Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Gros","sequence":"additional","affiliation":[{"name":"Stritch School of Medicine, Loyola University Chicago"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"Kron","sequence":"additional","affiliation":[{"name":"Peter MacCallum Cancer Centre"},{"name":"Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia"},{"name":"Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, VIC, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"Wood","sequence":"additional","affiliation":[{"name":"Hull University Teaching Hospitals NHS Trust"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.J.","family":"Martin","sequence":"additional","affiliation":[{"name":"Department of Clinical Physics and Bioengineering, Gartnavel Royal Hospital, University of Glasgow, Glasgow, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,8,27]]},"reference":[{"key":"e_1_3_2_2_1","unstructured":"AAPM 2008. The Measurement Reporting and Management of Radiation Dose in CT. AAPM Report 96 American Association of Physicists in Medicine Alexandria VA."},{"key":"e_1_3_2_3_1","unstructured":"AAPM 2020. The Design and Use of the ICRU\/AAPM CT Radiation Dosimetry Phantom: An Implementation of AAPM Report 111. AAPM Report 200 American Association of Physicists in Medicine Alexandria VA."},{"key":"e_1_3_2_4_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/60\/4\/1519"},{"key":"e_1_3_2_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12239"},{"key":"e_1_3_2_6_1","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2006.09.9515"},{"key":"e_1_3_2_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12824"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3190392"},{"key":"e_1_3_2_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2010.01.004"},{"key":"e_1_3_2_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2021.09.004"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/444\/1\/012017"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.semradonc.2007.07.003"}],"container-title":["Annals of the ICRP"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/01466453251412497","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/01466453251412497","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/01466453251412497","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,30]],"date-time":"2026-08-30T11:49:35Z","timestamp":1788090575000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/01466453251412497"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,27]]},"references-count":11,"alternative-id":["10.1177\/01466453251412497"],"URL":"https:\/\/doi.org\/10.1177\/01466453251412497","relation":{},"ISSN":["0146-6453","1872-969X"],"issn-type":[{"value":"0146-6453","type":"print"},{"value":"1872-969X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,27]]},"article-number":"01466453251412497"}}