{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T17:50:59Z","timestamp":1760982659561,"version":"build-2065373602"},"reference-count":19,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2000,9,1]],"date-time":"2000-09-01T00:00:00Z","timestamp":967766400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Parenter Enteral Nutr"],"published-print":{"date-parts":[[2000,9]]},"abstract":"<jats:p><jats:italic>Background:<\/jats:italic> Placement of feeding tubes in the transpyloric position can be helpful in the management of enterally fed patients with pancreatitis, gastric atony, enterocutaneous fistulae, or pulmonary aspiration risk. The attainment of transpyloric position is difficult, and numerous techniques have been proposed to help in achieving this location. Recently, the use of a magnet\u2010tipped feeding tube, dragged into proper position with an external magnet, has been described with an excellent success rate. <jats:italic>Methods:<\/jats:italic> At 10 participating institutions, practitioners were trained in the use of the device. Successful tube placement was determined by abdominal radiograph. <jats:italic>Results:<\/jats:italic> One hundred fifty\u2010six tube placements were attempted. Transpyloric position was obtained in 60%. Placement into the third portion of the duodenum or distal was obtained in only 32%. Analysis of the data did not reveal a learning curve at the institutions, and 7 of 10 had a 50% or lower success rate. Conclusions: Placement of feeding tubes with the assistance of a magnetic device was infrequently successful at the majority of institutions where it was attempted. We report a lower success rate than the original article, which described an 88% success rate of transpyloric intubation. Although this technique has a high failure rate, some individuals seem to be very successful using it, which could reduce the need for endoscopy or transport for the placement of feeding tubes. <jats:italic>(Journal of Parenteral and Enteral Nutrition<\/jats:italic> <jats:bold>24<\/jats:bold>:304\u2013307, 2000)<\/jats:p>","DOI":"10.1177\/0148607100024005304","type":"journal-article","created":{"date-parts":[[2008,5,14]],"date-time":"2008-05-14T19:51:26Z","timestamp":1210794686000},"page":"304-307","source":"Crossref","is-referenced-by-count":27,"title":["A Multicenter, Prospective Study of the Placement of Transpyloric Feeding Tubes with Assistance of a Magnetic Device"],"prefix":"10.1002","volume":"24","author":[{"given":"Michel","family":"Boivin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Howard","family":"Levy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James","family":"Hayes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"The Magnet\u2010Guided Enteral Feeding Tube Study Group","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2000,9]]},"reference":[{"key":"e_1_2_1_2_1","first-page":"297","volume-title":"Nutrition in Critical Illness","author":"Zaloga GP","year":"1994"},{"key":"e_1_2_1_3_1","first-page":"4","article-title":"The role of enteral nutrition in maintaining the structural and functional integrity of the gastrointestinal tract","volume":"1","author":"Demeo MT","year":"1996","journal-title":"Curr Issues Ent Nutr Support"},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s001340050677"},{"key":"e_1_2_1_5_1","first-page":"31","article-title":"Update on the management of gastroparesis","volume":"10","author":"McCallum RW","year":"1997","journal-title":"Hosp Pract"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199403000-00014"},{"key":"e_1_2_1_7_1","first-page":"A612","article-title":"Randomized trial of aspiration complications and caloric delivery with gastric versus small intestinal feedings (Abstr)","volume":"106","author":"Kearns PJ","year":"1994","journal-title":"Gastroenterology"},{"key":"e_1_2_1_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/0148607193017003271"},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1177\/0148607188012005469"},{"key":"e_1_2_1_10_1","first-page":"475","article-title":"The failure of conventional methods to promote spontaneous transpyloric feeding tube passage and the safety of intragastric feeding in the critically ill ventilated patient","volume":"176","author":"Marian M.","year":"1993","journal-title":"Surgery, Gynecology, and Obstetrics"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1177\/0148607188012002135"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.107.6.1686"},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1177\/088453369901400302"},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.100.6.1643"},{"key":"e_1_2_1_15_1","first-page":"79","article-title":"An improved method for transpyloric placement of nasoenteric feeding tubes","volume":"78","author":"Schulz MA","year":"1993","journal-title":"Int Surg"},{"key":"e_1_2_1_16_1","first-page":"S63","article-title":"Aspiration pneumonia rates in gastric versus jejunal feedings","volume":"20","author":"Levy HL","year":"1992","journal-title":"Crit Care Med"},{"key":"e_1_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199704000-00014"},{"key":"e_1_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-199202000-00008"},{"key":"e_1_2_1_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9610(91)90375-N"},{"key":"e_1_2_1_20_1","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/S1052-5157(18)30247-2","article-title":"Nasogastric and nasoenteric feeding tubes","volume":"8","author":"Levy HL","year":"1998","journal-title":"Gastrointest Endosc Clin N Am"}],"container-title":["Journal of Parenteral and Enteral Nutrition"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aspenjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1177\/0148607100024005304","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T13:06:06Z","timestamp":1760879166000},"score":1,"resource":{"primary":{"URL":"https:\/\/aspenjournals.onlinelibrary.wiley.com\/doi\/10.1177\/0148607100024005304"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,9]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2000,9]]}},"alternative-id":["10.1177\/0148607100024005304"],"URL":"https:\/\/doi.org\/10.1177\/0148607100024005304","archive":["Portico"],"relation":{},"ISSN":["0148-6071","1941-2444"],"issn-type":[{"type":"print","value":"0148-6071"},{"type":"electronic","value":"1941-2444"}],"subject":[],"published":{"date-parts":[[2000,9]]}}}