{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T23:36:18Z","timestamp":1777937778476,"version":"3.51.4"},"reference-count":106,"publisher":"Wiley","issue":"1S","license":[{"start":{"date-parts":[[2006,1,1]],"date-time":"2006-01-01T00:00:00Z","timestamp":1136073600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Parenter Enteral Nutr"],"published-print":{"date-parts":[[2006,1]]},"abstract":"<jats:p>Catheter\u2010related bloodstream infection and catheter occlusion are potential significant complications of parenteral nutrition therapy. The increased incidence and associated morbidity, mortality, increased costs, and qualityof\u2010life issues experienced with these adverse events necessitate specialized management of vascular access devices. The host coagulation response to biomaterials and the associated development of biofilm on vascular devices are complex phenomena. Multiple interventions are required to prevent access of bacteria to both intraluminal and extraluminal catheter surfaces, and the occurrence of catheter occlusion. The discovery of the biofilm form of microbial life and the associated recalcitrance of biofilm bacteria to antimicrobials has provided insight into the failure of current prevention, diagnostic, and treatment protocols. Critical interventions are presented correlating current evidence with new discoveries in pathogenesis. (Journal of Parenteral and Enteral Nutrition 30:S82\u2010S93, 2006)<\/jats:p>","DOI":"10.1177\/01486071060300s1s82","type":"journal-article","created":{"date-parts":[[2008,5,14]],"date-time":"2008-05-14T19:51:26Z","timestamp":1210794686000},"source":"Crossref","is-referenced-by-count":55,"title":["Evidence\u2010Based Practice in the Management of Vascular Access Devices for Home Parenteral Nutrition Therapy"],"prefix":"10.1002","volume":"30","author":[{"given":"Marcia","family":"Ryder","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,1]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.3201\/eid0702.010202"},{"key":"e_1_2_1_3_2","first-page":"114","article-title":"Home care in the United States: a national perspective [abstract]","volume":"21","year":"2000","journal-title":"Infect Control Hosp Epidemiol."},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.3201\/eid0803.010098"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM197404042901401"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9610(86)90153-4"},{"key":"e_1_2_1_7_2","volume-title":"North American Home Parenteral and Enteral Nutrition Patient Registry: Annual Report: 1992","author":"Steiger E.","year":"1994"},{"key":"e_1_2_1_8_2","first-page":"1","article-title":"Home paren\u2010teral nutrition: a systematic review","volume":"1","year":"1997","journal-title":"Health Technol Assess."},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.4065\/74.3.217"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3468(94)90107-4"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.transproceed.2003.10.040"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1054\/clnu.2001.0500"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1054\/clnu.2002.0578"},{"key":"e_1_2_1_14_2","first-page":"29","article-title":"Parenteral nutrition at home: NADYA register for the year 2000","volume":"18","year":"2003","journal-title":"Nutr Hosp."},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.3201\/eid0702.010211"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1017\/S0195941700080577"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1055-3207(18)30434-4"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1051-0443(07)61865-X"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0195-6701(03)00150-6"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1177\/00912709922008506"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01709583"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01682166"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1213\/01.ANE.0000087985.92227.FB"},{"key":"e_1_2_1_24_2","first-page":"15","article-title":"The role of biofilm in vascular catheter\u2010related infections","volume":"2","year":"2001","journal-title":"New Dev Vasc Dis."},{"key":"e_1_2_1_25_2","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1086\/646478","article-title":"Molecular epidemiology of coagulase negative staphylococci isolated from immunocompromised patients","volume":"13","year":"1992","journal-title":"Infect Control Hosp Epidemiol."},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1473-3099(04)01003-5"},{"key":"e_1_2_1_27_2","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1128\/jcm.26.1.8-12.1988","article-title":"Possible role of capillary action in pathogenesis of experimental catheter\u2010associated dermal tunnel infections","volume":"26","year":"1988","journal-title":"J Clin Microbiol."},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/00001432-200404000-00004"},{"key":"e_1_2_1_29_2","doi-asserted-by":"publisher","DOI":"10.1099\/00222615-48-5-451"},{"issue":"6","key":"e_1_2_1_30_2","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1099\/13500872-145-6-1325","article-title":"Flow cytometry and other techniques show that Staphylococcus aureus undergoes significant physiological changes in the early stages of surface\u2010attached culture","volume":"145","year":"1999","journal-title":"Microbiology."},{"key":"e_1_2_1_31_2","doi-asserted-by":"publisher","DOI":"10.1172\/JCI200320365"},{"key":"e_1_2_1_32_2","doi-asserted-by":"publisher","DOI":"10.3201\/eid0702.010226"},{"key":"e_1_2_1_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.tim.2004.11.004"},{"key":"e_1_2_1_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0958-1669(02)00318-X"},{"key":"e_1_2_1_35_2","doi-asserted-by":"publisher","DOI":"10.1038\/nrmicro821"},{"key":"e_1_2_1_36_2","doi-asserted-by":"publisher","DOI":"10.1128\/JB.186.14.4486-4491.2004"},{"key":"e_1_2_1_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-199207000-00013"},{"key":"e_1_2_1_38_2","doi-asserted-by":"publisher","DOI":"10.1128\/jb.184.4.1140-1154.2002"},{"key":"e_1_2_1_39_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199901073400101"},{"key":"e_1_2_1_40_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-003-2045-z"},{"key":"e_1_2_1_41_2","doi-asserted-by":"publisher","DOI":"10.1177\/112972980300400302"},{"key":"e_1_2_1_42_2","doi-asserted-by":"publisher","DOI":"10.1099\/mic.0.27385-0"},{"key":"e_1_2_1_43_2","doi-asserted-by":"publisher","DOI":"10.1067\/mic.2002.130391"},{"key":"e_1_2_1_44_2","doi-asserted-by":"publisher","DOI":"10.3201\/eid0702.010215"},{"key":"e_1_2_1_45_2","doi-asserted-by":"crossref","first-page":"2396","DOI":"10.1001\/jama.1987.03400170082027","article-title":"Evaluation of dressing regimes for prevention of infection with peripheral intravenous catheters: gauze, a transparent polyurethane dressing, and an iodophor\u2010transpar\u2010ent dressing","volume":"258","year":"1987","journal-title":"JAMA."},{"key":"e_1_2_1_46_2","doi-asserted-by":"publisher","DOI":"10.1093\/infdis\/160.4.644"},{"key":"e_1_2_1_47_2","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1016\/0195-6701(91)90257-9","article-title":"Laboratory and in\u2010vitro testing of skin antiseptics: a prediction for in\u2010vivo activity?","volume":"18","year":"1991","journal-title":"J Hosp Infect."},{"key":"e_1_2_1_48_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2672.2004.02403.x"},{"key":"e_1_2_1_49_2","doi-asserted-by":"publisher","DOI":"10.1128\/AAC.35.4.627"},{"key":"e_1_2_1_50_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhin.2004.06.001"},{"key":"e_1_2_1_51_2","unstructured":""},{"key":"e_1_2_1_52_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajic.2003.11.001"},{"key":"e_1_2_1_53_2","doi-asserted-by":"publisher","DOI":"10.1086\/377265"},{"key":"e_1_2_1_54_2","first-page":"332","article-title":"150 Years of hand disinfection: Semmelweis' heritage","volume":"22","year":"1997","journal-title":"Hygiene Med."},{"key":"e_1_2_1_55_2","doi-asserted-by":"publisher","DOI":"10.3201\/eid0702.010217"},{"key":"e_1_2_1_56_2","doi-asserted-by":"publisher","DOI":"10.1016\/0196-6553(88)90045-4"},{"key":"e_1_2_1_57_2","first-page":"26","article-title":"Skin antisepsis: past, present, and future","year":"2001","journal-title":"JVAD."},{"key":"e_1_2_1_58_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.0309-2402.2003.02852.x"},{"key":"e_1_2_1_59_2","first-page":"165","article-title":"Chlo\u2010rhexidine dressing for reduction in microbial colonization of the skin with central venous catheters: a prospective randomized controlled trial","volume":"42","year":"1999","journal-title":"J Hosp Infect."},{"key":"e_1_2_1_60_2","volume-title":"The Efficacy of a Chlo\u2010rhexidine\u2010Impregnated Sponge for the Prevention of Intravascular\u2010Related Infection: A Prospective, Randomized, Controlled, Multicenter Study","year":"2000"},{"key":"e_1_2_1_61_2","doi-asserted-by":"publisher","DOI":"10.1086\/502459"},{"key":"e_1_2_1_62_2","doi-asserted-by":"publisher","DOI":"10.1053\/jhin.1999.0636"},{"issue":"1","key":"e_1_2_1_63_2","first-page":"S57","article-title":"Developing an effective policy for home hygiene: a risk\u2010based approach","volume":"13","year":"2003","journal-title":"Int J Environ Health Res."},{"issue":"5","key":"e_1_2_1_64_2","first-page":"S161","article-title":"The impact of compliance on quality outcomes in the home infusion population","volume":"21","year":"1998","journal-title":"J Intraven Nurs."},{"key":"e_1_2_1_65_2","doi-asserted-by":"publisher","DOI":"10.1128\/JCM.31.3.475-479.1993"},{"key":"e_1_2_1_66_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-6553(98)70042-2"},{"key":"e_1_2_1_67_2","doi-asserted-by":"publisher","DOI":"10.1001\/archderm.1990.01670350055006"},{"key":"e_1_2_1_68_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0195-6701(03)00130-0"},{"key":"e_1_2_1_69_2","doi-asserted-by":"publisher","DOI":"10.1016\/0140-6736(91)90479-9"},{"key":"e_1_2_1_70_2","doi-asserted-by":"publisher","DOI":"10.1128\/AAC.32.11.1627"},{"key":"e_1_2_1_71_2","doi-asserted-by":"publisher","DOI":"10.1128\/AAC.46.2.327-332.2002"},{"key":"e_1_2_1_72_2","doi-asserted-by":"publisher","DOI":"10.1128\/AAC.47.11.3580-3585.2003"},{"key":"e_1_2_1_73_2","doi-asserted-by":"publisher","DOI":"10.1128\/AAC.46.6.1674-1679.2002"},{"key":"e_1_2_1_74_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.286.20.2531"},{"key":"e_1_2_1_75_2","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2000.18.6.1269"},{"key":"e_1_2_1_76_2","doi-asserted-by":"publisher","DOI":"10.1128\/AAC.43.9.2200"},{"key":"e_1_2_1_77_2","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.1990.8.9.1591"},{"key":"e_1_2_1_78_2","doi-asserted-by":"publisher","DOI":"10.1086\/501887"},{"key":"e_1_2_1_79_2","first-page":"S18","article-title":"Tetra sodium EDTA: a novel antimicrobial agent superior to ciprofloxacin in eradicating biofilm bacteria: implications for catheter\u2010related bloodstream infections [abstract]","volume":"29","year":"2005","journal-title":"JPEN J Parenter Enteral Nutr."},{"key":"e_1_2_1_80_2","doi-asserted-by":"publisher","DOI":"10.1128\/JCM.42.7.3073-3076.2004"},{"key":"e_1_2_1_81_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-0038-1653727"},{"key":"e_1_2_1_82_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-200011000-00039"},{"key":"e_1_2_1_83_2","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1128\/jcm.35.3.641-646.1997","article-title":"Diagnosis of triple\u2010lumen catheter infection: comparison of roll plate, sonication, and flushing methodologies","volume":"35","year":"1997","journal-title":"J Clin Microbiol."},{"key":"e_1_2_1_84_2","first-page":"631","article-title":"Analysis of the research about heparinized versus nonheparinized intravascular lines","volume":"20","year":"1991","journal-title":"Heart Lung."},{"key":"e_1_2_1_85_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006199-199111000-00002"},{"key":"e_1_2_1_86_2","doi-asserted-by":"publisher","DOI":"10.1097\/00043426-199122000-00005"},{"key":"e_1_2_1_87_2","first-page":"651","article-title":"Hickman catheter clots: a common occurrence despite daily heparin flushing","volume":"71","year":"1987","journal-title":"Cancer Treat Rep."},{"key":"e_1_2_1_88_2","doi-asserted-by":"publisher","DOI":"10.1007\/s005200050065"},{"key":"e_1_2_1_89_2","first-page":"1073","article-title":"Reinfusion of discard from venous access devices","volume":"25","year":"1998","journal-title":"Oncol Nurs Forum."},{"key":"e_1_2_1_90_2","doi-asserted-by":"publisher","DOI":"10.2309\/155288504774660327"},{"key":"e_1_2_1_91_2","doi-asserted-by":"publisher","DOI":"10.1086\/344952"},{"key":"e_1_2_1_92_2","unstructured":""},{"key":"e_1_2_1_93_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.MAT.0000094040.54794.2D"},{"key":"e_1_2_1_94_2","doi-asserted-by":"publisher","DOI":"10.1128\/JCM.39.2.750-753.2001"},{"key":"e_1_2_1_95_2","first-page":"34","article-title":"Preventing central venous access device occlusions with saline only flush by use of an adapter","year":"2001","journal-title":"JVAD."},{"key":"e_1_2_1_96_2","first-page":"117","article-title":"Do needleless intravenous systems increase the risk of infection?","volume":"22","year":"1999","journal-title":"J Intraven Nurs."},{"key":"e_1_2_1_97_2","doi-asserted-by":"publisher","DOI":"10.1177\/0148607104028002113"},{"key":"e_1_2_1_98_2","doi-asserted-by":"publisher","DOI":"10.2309\/155288504774596752"},{"key":"e_1_2_1_99_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1051-0443(07)61676-5"},{"key":"e_1_2_1_100_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.173.5.10541127"},{"key":"e_1_2_1_101_2","first-page":"261","article-title":"Clinical evaluation of a positive pressure device to prevent central venous catheter occlusion: results of a pilot study","volume":"5","year":"2001","journal-title":"Clin J Oncol Nurs."},{"key":"e_1_2_1_102_2","first-page":"31","article-title":"The effects of positive pressure devices on catheter occlusions","volume":"5","year":"2000","journal-title":"JVAD."},{"key":"e_1_2_1_103_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajic.2003.12.004"},{"key":"e_1_2_1_104_2","doi-asserted-by":"publisher","DOI":"10.1086\/314592"},{"key":"e_1_2_1_105_2","doi-asserted-by":"publisher","DOI":"10.2307\/30141352"},{"key":"e_1_2_1_106_2","doi-asserted-by":"publisher","DOI":"10.2307\/30141423"},{"key":"e_1_2_1_107_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-6553(97)90081-X"}],"container-title":["Journal of Parenteral and Enteral Nutrition"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/01486071060300S1S82","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aspenjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1177\/01486071060300S1S82","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T11:01:08Z","timestamp":1760871668000},"score":1,"resource":{"primary":{"URL":"https:\/\/aspenjournals.onlinelibrary.wiley.com\/doi\/10.1177\/01486071060300S1S82"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,1]]},"references-count":106,"journal-issue":{"issue":"1S","published-print":{"date-parts":[[2006,1]]}},"alternative-id":["10.1177\/01486071060300S1S82"],"URL":"https:\/\/doi.org\/10.1177\/01486071060300s1s82","archive":["Portico"],"relation":{},"ISSN":["0148-6071","1941-2444"],"issn-type":[{"value":"0148-6071","type":"print"},{"value":"1941-2444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,1]]}}}