{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T00:19:14Z","timestamp":1760660354544,"version":"build-2065373602"},"reference-count":15,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[1980,9,1]],"date-time":"1980-09-01T00:00:00Z","timestamp":336614400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Parenter Enteral Nutr"],"published-print":{"date-parts":[[1980,9]]},"abstract":"<jats:p>In an effort to diminish the incidence of catheter related sepsis in total parenteral nutrition, the effect of a 10\u2010cm long subcutaneous tunnel was studied in a prospective randomized manner. This tunnel created a longer anatomical distance between puncture site of the catheter and the subclavian vein. In the control group, a direct puncture technique was employed. Eighty\u2010one catheters (group A) were inserted according to the direct technique, 69 (group B) were tunnelled. Catheter sepsis was defined as an episode of clinical sepsis for which no other cause can be identified and which resolves upon removal of the catheter. No significant differences were noted between the two groups, suggesting that tunnelling of subclavian PVC catheters does not diminish the incidence of catheter related sepsis.<\/jats:p>","DOI":"10.1177\/014860718000400516","type":"journal-article","created":{"date-parts":[[2017,7,4]],"date-time":"2017-07-04T09:02:15Z","timestamp":1499158935000},"page":"514-517","source":"Crossref","is-referenced-by-count":11,"title":["TPN Catheter Sepsis: Lack of Effect of Subcutaneous Tunnelling of PVC Catheters on Sepsis Rate"],"prefix":"10.1002","volume":"4","author":[{"given":"Maartin M. F. von","family":"Meyenfeldt","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jouwert","family":"Stapert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter C. M. de","family":"Jong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter B.","family":"Soeters","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert I. C.","family":"Wesdorp","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacobus M.","family":"Greep","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[1980,9]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-197911000-00001"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-197709000-00002"},{"key":"e_1_2_1_4_2","first-page":"363","article-title":"Immunodepression after major surgery in normal patients","volume":"78","author":"Slade MS","year":"1975","journal-title":"Surgery"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-197402000-00010"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM197404042901401"},{"key":"e_1_2_1_7_2","first-page":"377","article-title":"The use of hyperalimentation in patients with potential sepsis","volume":"138","author":"Copeland EM","year":"1974","journal-title":"Surg Gynecol Obstet"},{"key":"e_1_2_1_8_2","first-page":"141","article-title":"Preventing infection in intravenous therapy. Anesthesia and Analgesia","volume":"56","author":"Maki DG","year":"1977","journal-title":"Curr Res"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-4804(77)90035-X"},{"key":"e_1_2_1_10_2","first-page":"173","article-title":"Prophylaxis against infection and septicemia in parenteral nutrition via central intravenous catheters","volume":"141","author":"Holm I","year":"1975","journal-title":"Acta Chir Scand"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(78)92601-6"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1969.01340160042009"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1973.03220120030007"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM196503182721103"},{"key":"e_1_2_1_15_2","first-page":"205","article-title":"Five years' experience with a right atrial catheter for prolonged parenteral nutrition at home","volume":"143","author":"Riella MC","year":"1976","journal-title":"Surg Gynecol Obstet"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0011-5029(78)80002-9"}],"container-title":["Journal of Parenteral and Enteral Nutrition"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aspenjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1177\/014860718000400516","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T13:40:41Z","timestamp":1760622041000},"score":1,"resource":{"primary":{"URL":"https:\/\/aspenjournals.onlinelibrary.wiley.com\/doi\/10.1177\/014860718000400516"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1980,9]]},"references-count":15,"journal-issue":{"issue":"5","published-print":{"date-parts":[[1980,9]]}},"alternative-id":["10.1177\/014860718000400516"],"URL":"https:\/\/doi.org\/10.1177\/014860718000400516","archive":["Portico"],"relation":{},"ISSN":["0148-6071","1941-2444"],"issn-type":[{"type":"print","value":"0148-6071"},{"type":"electronic","value":"1941-2444"}],"subject":[],"published":{"date-parts":[[1980,9]]}}}