{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T17:51:03Z","timestamp":1760982663026,"version":"build-2065373602"},"reference-count":12,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[1993,11,1]],"date-time":"1993-11-01T00:00:00Z","timestamp":752112000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Parenter Enteral Nutr"],"published-print":{"date-parts":[[1993,11]]},"abstract":"<jats:p>Radiographic confirmation of enteral feeding tube placement is a common practice representing considerable expense and causing delay in the initiation of enteral nutrition therapy. We evaluated an enteral feeding tube with a pH sensor, which allows immediate verification of the location of the tube by assessment of the pH upon insertion. Insertion pHs were obtained for 24 intensive care unit patients requiring feeding tube placement. Placement was verified radiographically and compared with expected location on the basis of the pH profile. The radiograph and the insertion pH profile were in agreement in 87.5% (21 of 24) of the cases. Concomitant use of histamine blockers did not affect the ability of the pH sensor to detect placement accurately (Fisher's Exact Test, p 5.71) Use of these pH measurements eliminates the need for radiographic documentation of placement, provides a savings for the patient, and may be beneficial in promoting enteral feedings in critically ill patients. (<jats:italic>Journal of Parenteral and Enteral Nutrition<\/jats:italic> <jats:bold>17:<\/jats:bold>562\u2013565, 1993)<\/jats:p>","DOI":"10.1177\/0148607193017006562","type":"journal-article","created":{"date-parts":[[2008,5,14]],"date-time":"2008-05-14T19:51:26Z","timestamp":1210794686000},"page":"562-565","source":"Crossref","is-referenced-by-count":28,"title":["Nasointestinal Tube Placement With a pH Sensor Feeding Tube"],"prefix":"10.1002","volume":"17","author":[{"given":"Darell E.","family":"Heiselman","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robin R.","family":"Vidovich","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gary","family":"Milkovich","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lisa D.","family":"Black","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[1993,11]]},"reference":[{"key":"e_1_2_1_2_1","first-page":"1382","volume-title":"Cecil Textbook of Medicine, 6th Ed, Vol 2","author":"Wyngaarden JB","year":"1982"},{"key":"e_1_2_1_3_1","doi-asserted-by":"publisher","DOI":"10.1177\/0148607187011002210"},{"key":"e_1_2_1_4_1","first-page":"203","article-title":"Narrow bore nasogastric feeding tube complications","volume":"2","author":"Bohnker BK","year":"1987","journal-title":"NCP"},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.87.1.131"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1984.03340420062028"},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-198001000-00006"},{"key":"e_1_2_1_8_1","first-page":"95","article-title":"Pre and post\u2010pyloric enteral feeding: Analysis of safety and complications (Abstr)","volume":"8","author":"Kiver KF","year":"1984","journal-title":"JPEN"},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1177\/0148607183007006546"},{"key":"e_1_2_1_10_1","first-page":"285","article-title":"Monitoring patients with nasally placed feeding tubes","volume":"14","author":"Metheny N.","year":"1985","journal-title":"Heart Lung"},{"issue":"8","key":"e_1_2_1_11_1","first-page":"11","article-title":"Enteral tube feedings utilizing a pH sensor enteral feeding tube","volume":"8","author":"Strong RM","year":"1988","journal-title":"Nutr Supp Serv"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199009000-00016"},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199004000-00009"}],"container-title":["Journal of Parenteral and Enteral Nutrition"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aspenjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1177\/0148607193017006562","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T18:45:06Z","timestamp":1760640306000},"score":1,"resource":{"primary":{"URL":"https:\/\/aspenjournals.onlinelibrary.wiley.com\/doi\/10.1177\/0148607193017006562"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1993,11]]},"references-count":12,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1993,11]]}},"alternative-id":["10.1177\/0148607193017006562"],"URL":"https:\/\/doi.org\/10.1177\/0148607193017006562","archive":["Portico"],"relation":{},"ISSN":["0148-6071","1941-2444"],"issn-type":[{"type":"print","value":"0148-6071"},{"type":"electronic","value":"1941-2444"}],"subject":[],"published":{"date-parts":[[1993,11]]}}}