{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T21:40:11Z","timestamp":1790718011402,"version":"4.1.0"},"reference-count":11,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2014,3,4]],"date-time":"2014-03-04T00:00:00Z","timestamp":1393891200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["aao-hnsfjournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Otolaryngol.--head neck surg."],"published-print":{"date-parts":[[2014,5]]},"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>To obtain identical laboratory measures of 8 (surgical and nonsurgical) bone conduction devices and relate them to clinical function.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study Design<\/jats:title><jats:p>Each device was measured with a single laboratory system and characterized with descriptive statistics.<\/jats:p><\/jats:sec><jats:sec><jats:title>Setting<\/jats:title><jats:p>Laboratory.<\/jats:p><\/jats:sec><jats:sec><jats:title>Subjects and Methods<\/jats:title><jats:p>Seven surgical devices (Intenso, BP110, BP100, and Cordelle [Cochlear, Denver, Colorado]; Ponto Pro and Ponto Pro Power [Oticon Medical, Somerset, New Jersey]; and Alpha 2 [Sophono, Inc, Boulder, Colorado]) and 1\u00a0nonsurgical dental device (SoundBite; Sonitus Medical, Inc, San Mateo, California) constituted the independent variables. Measured maximum output and gain parameters were the dependent variables.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Maximum output varied across devices in the pure\u2010tone average (PTA; 500\u20103000\u00a0Hz) frequency range (mean, 109.7\u00a0dB re 1 \u00b5N; range, 98.8\u2010119.2\u00a0dB) and in the above\u2010PTA (4000\u20108000\u00a0Hz) frequency range (mean, 102.6\u00a0dB re 1 \u00b5N; range, 88.99\u2010119.6\u00a0dB). Maximum gain varied in the PTA frequency range (mean, 40\u00a0dB; range, 29.1\u201049.1\u00a0dB) and was higher in the frequency range above the PTA (mean, 32.0\u00a0dB; range, 20.8\u201046.0\u00a0dB).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>All devices have sufficient maximum output and gain for the PTA frequency range for single\u2010sided deafness (SSD). The devices differed in maximum output and gain for the frequency range above the PTA, a consideration for accommodating presbycusis and optimizing auditory function for SSD. The surgical devices have less maximum output and gain in the above\u2010PTA range than in the PTA range. The nonsurgical dental device had the highest output (up to 30\u00a0dB higher) and gain (up to 26\u00a0dB higher) in the above\u2010PTA range.<\/jats:p><\/jats:sec>","DOI":"10.1177\/0194599814524530","type":"journal-article","created":{"date-parts":[[2014,3,5]],"date-time":"2014-03-05T00:33:01Z","timestamp":1393979581000},"page":"866-871","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Bone Conduction Hearing: Device Auditory Capability to Aid in Device Selection"],"prefix":"10.1002","volume":"150","author":[{"given":"Mark J.","family":"Syms","sequence":"first","affiliation":[{"name":"Neurotology Barrow Neurological Institute Phoenix Arizona USA"},{"name":"Otology\/Neurotology Arizona Ear Center Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kelly E.","family":"Hernandez","sequence":"additional","affiliation":[{"name":"Audiology Arizona Ear Center Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2014,3,4]]},"reference":[{"key":"e_1_2_9_2_1","volume-title":"Single Sided Deafness","author":"Valente M","year":"2011"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1002\/lary.24091"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.3109\/14992027.2011.635315"},{"key":"e_1_2_9_5_1","first-page":"103","article-title":"Factors influencing the decision for Baha in unilateral deafness: the Bern benefit in single\u2010sided deafness questionnaire","volume":"71","author":"Kompis M","year":"2011","journal-title":"Adv Otorhinolaryngol"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.3109\/00016489.2012.655862"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0b013e3182362790"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1080\/14992020802662956"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0b013e3181e9770e"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-012-2151-z"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.3109\/14992027.2013.809483"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0b013e3181ecd002"}],"container-title":["Otolaryngology\u2013Head and Neck Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1177\/0194599814524530","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1177\/0194599814524530","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aao-hnsfjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1177\/0194599814524530","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T12:16:57Z","timestamp":1760962617000},"score":1,"resource":{"primary":{"URL":"https:\/\/aao-hnsfjournals.onlinelibrary.wiley.com\/doi\/10.1177\/0194599814524530"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3,4]]},"references-count":11,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2014,5]]}},"alternative-id":["10.1177\/0194599814524530"],"URL":"https:\/\/doi.org\/10.1177\/0194599814524530","archive":["Portico"],"relation":{},"ISSN":["0194-5998","1097-6817"],"issn-type":[{"value":"0194-5998","type":"print"},{"value":"1097-6817","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,3,4]]},"assertion":[{"value":"2013-09-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2014-01-29","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2014-03-04","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}