{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T22:06:15Z","timestamp":1791324375045,"version":"4.3.1"},"reference-count":28,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2019,4,9]],"date-time":"2019-04-09T00:00:00Z","timestamp":1554768000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["aao-hnsfjournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Otolaryngol.--head neck surg."],"published-print":{"date-parts":[[2019,8]]},"abstract":"<jats:sec><jats:title>Objectives<\/jats:title><jats:p>To describe parathyroid computed tomography angiography (PCTA), determine its accuracy, and, as a secondary objective, calculate its mean radiation dosimetry.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study Design<\/jats:title><jats:p>Retrospective chart review of patients who underwent parathyroidectomy for primary hyperparathyroidism from 2007 to 2015.<\/jats:p><\/jats:sec><jats:sec><jats:title>Setting<\/jats:title><jats:p>Single\u2010center tertiary care academic military hospital.<\/jats:p><\/jats:sec><jats:sec><jats:title>Subjects and Methods<\/jats:title><jats:p>PCTA is a 2\u2010phase computed tomography imaging technique that uses individualized timing of contrast infusion and novel patient positioning to accurately identify parathyroid adenomas. Consecutive patients who underwent parathyroidectomy for primary hyperparathyroidism from 2007 to 2015 were reviewed; 55% of patients were women. The mean age was 50.9 years (range, 26\u201068 years). Sensitivity and specificity were calculated as well as mean radiation dosimetry and timing of contrast.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>A total of 108 procedures were performed during the study period. Twenty\u2010one patients undergoing 22\u00a0PCTAs after prior sestamibi scans were nonlocalizing or equivocal. In this group, there were 15 true\u2010positive, 3 false\u2010positive, 4 true\u2010negative, and 0 false\u2010negative PCTAs. This represents a sensitivity of 100% (95% CI, 74.7%\u2010100%) and a specificity of 57% (95% CI, 20%\u201088%). The mean calculated radiation dose was 5.15\u00a0mSv. In the most recent studies, a mean dose of 4.1\u00a0mSv was calculated. The ideal time of image acquisition contrast administration varied from 20 to 30\u00a0seconds after contrast infusion.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>PCTA is a new technique in anatomic imaging for hyperparathyroidism. In a single\u2010center, single\u2010radiologist retrospective study, it demonstrates excellent accuracy for patients with parathyroid adenomas that are otherwise difficult to localize preoperatively. Preliminary experience suggests that its use may be indicated as a primary imaging modality in the future.<\/jats:p><\/jats:sec>","DOI":"10.1177\/0194599819842106","type":"journal-article","created":{"date-parts":[[2019,4,9]],"date-time":"2019-04-09T15:01:29Z","timestamp":1554822089000},"page":"251-256","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Parathyroid Computed Tomography Angiography: Early Experience with a Novel Imaging Technique in Primary Hyperparathyroidism"],"prefix":"10.1002","volume":"161","author":[{"given":"Isaac E.","family":"Schwartz","sequence":"first","affiliation":[{"name":"Department of Otolaryngology\u2013Head and Neck Surgery US Navy Hospital Naples Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory G.","family":"Capra","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology\u2013Head and Neck Surgery Naval Medical Center Portsmouth Portsmouth Virginia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David P.","family":"Mullin","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology\u2013Head and Neck Surgery Naval Medical Center San Diego San Diego California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Terence E.","family":"Johnson","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology\u2013Head and Neck Surgery Naval Medical Center San Diego San Diego California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gilbert E.","family":"Boswell","sequence":"additional","affiliation":[{"name":"Department of Radiology Naval Medical Center San Diego San Diego CA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2019,4,9]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjoto.2011.10.010"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-200205000-00008"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1097\/SLA.0b013e318208fed9"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.soc.2015.08.012"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00423-006-0076-y"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1245\/s10434-011-1870-5"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/0194599814562195"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2006.07.028"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jamcollsurg.2007.12.044"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2010.09.002"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/RCT.0b013e31828beb34"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2015142393"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2016.04.016"},{"key":"e_1_2_8_15_1","first-page":"245","article-title":"CT dosimetry: comparison of measurement techniques and devices","volume":"28","author":"Bauhs JA","year":"2008","journal-title":"Radiogr Rev Publ Radiol Soc N Am Inc"},{"key":"e_1_2_8_16_1","unstructured":"VassarStats: Statistical Computation.http:\/\/vassarstats.net\/. Accessed September 17 2017."},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1177\/0194599812458767"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1245\/s10434-014-4331-0"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2014.11.010"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1177\/0194599815599372"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.10.4459"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/lary.26201"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijsu.2015.01.005"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1097\/RCT.0000000000000821"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1177\/0194599815618199"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4425"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1245\/s10434-010-1507-0"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.12110852"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3715"}],"container-title":["Otolaryngology\u2013Head and Neck Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1177\/0194599819842106","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1177\/0194599819842106","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aao-hnsfjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1177\/0194599819842106","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T10:01:38Z","timestamp":1760954498000},"score":1,"resource":{"primary":{"URL":"https:\/\/aao-hnsfjournals.onlinelibrary.wiley.com\/doi\/10.1177\/0194599819842106"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4,9]]},"references-count":28,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,8]]}},"alternative-id":["10.1177\/0194599819842106"],"URL":"https:\/\/doi.org\/10.1177\/0194599819842106","archive":["Portico"],"relation":{},"ISSN":["0194-5998","1097-6817"],"issn-type":[{"value":"0194-5998","type":"print"},{"value":"1097-6817","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,4,9]]},"assertion":[{"value":"2018-10-08","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-03-15","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-04-09","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}