{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T22:06:09Z","timestamp":1791410769223,"version":"4.3.3"},"reference-count":20,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2009,8,1]],"date-time":"2009-08-01T00:00:00Z","timestamp":1249084800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Asian Cardiovasc Thorac Ann"],"published-print":{"date-parts":[[2009,8]]},"abstract":"<jats:p>\n                    Post-cardiotomyright ventricular failure is a serious complication that frequently results in adverse outcomes. We reviewed our experience with the Impella Recover RD (Impella Cardiosystems GMbH, Aachen, Germany). From January 2007 to December 2007, 7 patients (5 males, 54 + 7 years old) had this device implanted for temporary support after heart transplantation in 4, after repeat mitral valve replacement in 2, and with a left ventricular assist device in 1. Devices were implanted during initial operation (\n                    <jats:italic toggle=\"yes\">n<\/jats:italic>\n                    = 5) or shortly thereafter (\n                    <jats:italic toggle=\"yes\">n<\/jats:italic>\n                    = 2). Six patients underwent implantation without cardiopulmonary bypass. Effective support with pump flows of 4.0-4.5 L \u00b7 min\n                    <jats:sup>\u22121<\/jats:sup>\n                    and adequate unloading (central venous pressure decreased from 15.3 \u00b1 1.4 to 9.4 \u00b1 1.2 mm Hg) was achieved in all patients. Patients were assisted for a mean duration of 4.9 \u00b1 4.5 days. Three patients could be weaned after 7.0 \u00b1 5.6 days of support and underwent device explantation without cardiopulmonary bypass. One of these patients died of recurrent right ventricular failure, 2 remained stable but died later of sepsis. The patient with a left ventricular assist device was switched to an alternative device for prolonged support. Two patients experienced pump dysfunction. Our preliminary experience shows that the Impella Recover RD is an effective device that can be easily implanted and explanted. However, its mechanical reliability needs to be improved.\n                  <\/jats:p>","DOI":"10.1177\/0218492309338121","type":"journal-article","created":{"date-parts":[[2013,5,6]],"date-time":"2013-05-06T09:37:22Z","timestamp":1367833042000},"page":"395-400","source":"Crossref","is-referenced-by-count":24,"title":["Temporary Right Ventricular Support with Impella Recover RD Axial Flow Pump"],"prefix":"10.1177","volume":"17","author":[{"given":"Hiroshi","family":"Sugiki","sequence":"first","affiliation":[{"name":"Department of Cardiothoracic Surgery Henri Mondor Hospital Cr\u00e9teil, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuniki","family":"Nakashima","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic Surgery Henri Mondor Hospital Cr\u00e9teil, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emmanuelle","family":"Vermes","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic Surgery Henri Mondor Hospital Cr\u00e9teil, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Loisance","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic Surgery Henri Mondor Hospital Cr\u00e9teil, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Kirsch","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic Surgery Henri Mondor Hospital Cr\u00e9teil, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2009,8]]},"reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2003.09.022"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(99)00525-1"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1159\/000007000"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-200212000-00009"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1177\/096721090000800101"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1053-2498(00)00138-8"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(01)03406-3"},{"key":"e_1_3_1_9_2","first-page":"1844","article-title":"Bridge experience with long-term implantable left ventricular assist devices","volume":"95","author":"Oz MC","year":"1997","unstructured":"Oz MC, Argenziano M, Catanese KA, Gardocki MT, Goldstein DJ, Ashton RC, Bridge experience with long-term implantable left ventricular assist devices. Are they an alternative to transplantation? Circulation 1997; 95: 1844\u201352","journal-title":"Are they an alternative to transplantation? Circulation"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-003-2025-3"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(99)00246-5"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(00)02644-8"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(99)00580-9"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1177\/039139889401700406"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.1994.tb03344.x"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/0003-4975(94)00048-C"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2005.08.003"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2006.02.017"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(03)00512-8"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(03)00250-1"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/0003-4975(95)01010-6"}],"container-title":["Asian Cardiovascular and Thoracic Annals"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0218492309338121","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0218492309338121","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0218492309338121","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T15:14:16Z","timestamp":1777389256000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0218492309338121"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,8]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2009,8]]}},"alternative-id":["10.1177\/0218492309338121"],"URL":"https:\/\/doi.org\/10.1177\/0218492309338121","relation":{},"ISSN":["0218-4923","1816-5370"],"issn-type":[{"value":"0218-4923","type":"print"},{"value":"1816-5370","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,8]]}}}