{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T17:27:08Z","timestamp":1777915628812,"version":"3.51.4"},"reference-count":13,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2015,11,2]],"date-time":"2015-11-02T00:00:00Z","timestamp":1446422400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Perfusion"],"published-print":{"date-parts":[[2016,5]]},"abstract":"<jats:p>This case study reports the operative management of a 63-year-old male patient following implantation of the HeartMate II (HMII) left ventricular assist device (LVAD), with a non-compliant left ventricle (LV) and a reduced right ventricular (RV) end-diastolic volume. Intraoperatively, the patient had a thin, fragile LV wall with laminated clot; a ventricular septal defect was encountered during removal of the clot. Along with an aortic valve repair, the LV and the septum were reconstructed with multiple bovine pericardium patches, thus, moderately reducing the RV and LV stroke volume. A difference in cardiac output via a Swan-Ganz catheter (approximately 1.5 l\/min) was observed as opposed to the HMII\u2019s estimated flow. The result was later replicated and verified in vitro via the Donovan Mock Circulation System (DMCS), where about 2 l\/min lower flow on the HMII system was observed. In conclusion, the HMII flow rate displayed can be inaccurate and should only be used for trending.<\/jats:p>","DOI":"10.1177\/0267659115614639","type":"journal-article","created":{"date-parts":[[2015,11,3]],"date-time":"2015-11-03T20:32:51Z","timestamp":1446582771000},"page":"349-352","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":1,"title":["Case Report: Disparate flow in HeartMate II patient with extensive left ventricle repair"],"prefix":"10.1177","volume":"31","author":[{"given":"Phat L.","family":"Tran","sequence":"first","affiliation":[{"name":"Department of Medicine, University of Arizona, Tucson, AZ, USA"},{"name":"Artificial Heart Program, University of Arizona, Tucson, AZ, USA"},{"name":"Department of Pharmacology, University of Arizona, Tucson, AZ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshinobu","family":"Kazui","sequence":"additional","affiliation":[{"name":"Artificial Heart Program, University of Arizona, Tucson, AZ, USA"},{"name":"CardioThoracic Surgery, University of Arizona, Tucson, AZ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Viktor","family":"Perovic","sequence":"additional","affiliation":[{"name":"Department of Medicine, University of Arizona, Tucson, AZ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philmon","family":"Mikail","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, University of Arizona, Tucson, AZ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Scott","family":"Lick","sequence":"additional","affiliation":[{"name":"Department of Medicine, University of Arizona, Tucson, AZ, USA"},{"name":"Artificial Heart Program, University of Arizona, Tucson, AZ, USA"},{"name":"CardioThoracic Surgery, University of Arizona, Tucson, AZ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard","family":"Smith","sequence":"additional","affiliation":[{"name":"Artificial Heart Program, University of Arizona, Tucson, AZ, USA"},{"name":"CardioThoracic Surgery, University of Arizona, Tucson, AZ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edward W.","family":"Betterton","sequence":"additional","affiliation":[{"name":"Artificial Heart Program, University of Arizona, Tucson, AZ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raj","family":"Venkat","sequence":"additional","affiliation":[{"name":"Artificial Heart Program, University of Arizona, Tucson, AZ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jessika","family":"Iwanski","sequence":"additional","affiliation":[{"name":"Artificial Heart Program, University of Arizona, Tucson, AZ, USA"},{"name":"Department of Pharmacology, University of Arizona, Tucson, AZ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raymond K.","family":"Wong","sequence":"additional","affiliation":[{"name":"Artificial Heart Program, University of Arizona, Tucson, AZ, USA"},{"name":"Department of Pharmacology, University of Arizona, Tucson, AZ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marvin J.","family":"Slepian","sequence":"additional","affiliation":[{"name":"Department of Medicine, University of Arizona, Tucson, AZ, USA"},{"name":"Biomedical Engineering, University of Arizona, Tucson, AZ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zain","family":"Khalpey","sequence":"additional","affiliation":[{"name":"Department of Medicine, University of Arizona, Tucson, AZ, USA"},{"name":"Artificial Heart Program, University of Arizona, Tucson, AZ, USA"},{"name":"CardioThoracic Surgery, University of Arizona, Tucson, AZ, USA"},{"name":"Biomedical Engineering, University of Arizona, Tucson, AZ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2015,11,2]]},"reference":[{"key":"bibr1-0267659115614639","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0b013e3182009701"},{"key":"bibr2-0267659115614639","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.109.192667"},{"key":"bibr3-0267659115614639","doi-asserted-by":"publisher","DOI":"10.1161\/hc4901.102568"},{"key":"bibr4-0267659115614639","doi-asserted-by":"publisher","DOI":"10.1002\/clc.4960231503"},{"key":"bibr5-0267659115614639","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2009.12.017"},{"key":"bibr6-0267659115614639","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2009.1062"},{"key":"bibr7-0267659115614639","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa012175"},{"key":"bibr8-0267659115614639","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2009.02.015"},{"key":"bibr9-0267659115614639","volume-title":"Thoratec, Inc","author":"HeartMate II LVAD operating manual"},{"key":"bibr10-0267659115614639","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e3182496d9a"},{"key":"bibr11-0267659115614639","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2008.10.007"},{"key":"bibr12-0267659115614639","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0000000000000192"},{"key":"bibr13-0267659115614639","unstructured":"Crosby JR. Expanding the performance envelope of the total artificial heart: physiological characterization, development of a heart failure model, and evaluation tool for mechanical circulatory support devices. PhD Thesis, University of Arizona, USA, 2014."}],"container-title":["Perfusion"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0267659115614639","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0267659115614639","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0267659115614639","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T17:25:38Z","timestamp":1777656338000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0267659115614639"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11,2]]},"references-count":13,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2016,5]]}},"alternative-id":["10.1177\/0267659115614639"],"URL":"https:\/\/doi.org\/10.1177\/0267659115614639","relation":{},"ISSN":["0267-6591","1477-111X"],"issn-type":[{"value":"0267-6591","type":"print"},{"value":"1477-111X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,11,2]]}}}