{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T11:15:54Z","timestamp":1778152554183,"version":"3.51.4"},"reference-count":11,"publisher":"SAGE Publications","issue":"1_suppl","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Perfusion"],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Extracorporeal membrane oxygenation (ECMO) provides lifesaving support for severe respiratory and cardiac failure. Hybrid modes such as venoarteriopulmonary (VAP) may be necessary when conventional modes fail to meet complex physiological demands.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case Report<\/jats:title>\n                    <jats:p>A 31-year-old woman with dermatomyositis-associated interstitial lung disease developed severe respiratory failure. She was initiated on venovenous (VV) ECMO, later complicated by right ventricular injury (RVI) requiring conversion to venopulmonary (VP) ECMO, and ultimately required hybrid VAP ECMO for progressive RVI and cardiogenic shock while awaiting heart-lung transplantation. The unique cannulation configuration provided additional cardiorespiratory support and hemodynamic stabilization, which later enabled safe transfer for transplantation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>Hybrid VAP ECMO may provide effective rescue support for patients with refractory RVI and respiratory failure despite VP ECMO, preserve a surgically na\u00efve chest, avoid differential oxygenation, and serve as a bridge to combined heart-lung transplant.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Hybrid VAP ECMO represents an effective salvage strategy and bridge-to-transplant in complex cardiopulmonary failure.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/02676591251413741","type":"journal-article","created":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T06:30:36Z","timestamp":1778049036000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Hybrid venoarteriopulmonary extracorporeal membrane oxygenation for severe respiratory failure and refractory right ventricular injury: A case report"],"prefix":"10.1177","volume":"41","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9323-0547","authenticated-orcid":false,"given":"Joseph M.","family":"Brewer","sequence":"first","affiliation":[{"name":"INTEGRIS Health Baptist Medical Center"},{"name":"Queens University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jordan","family":"Phillips","sequence":"additional","affiliation":[{"name":"INTEGRIS Health Baptist Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Obaid","family":"Ashraf","sequence":"additional","affiliation":[{"name":"INTEGRIS Health Baptist Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Clayne","family":"Benson","sequence":"additional","affiliation":[{"name":"INTEGRIS Health Baptist Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mircea R.","family":"Mihu","sequence":"additional","affiliation":[{"name":"INTEGRIS Health Baptist Medical Center"},{"name":"Oklahoma State University Health Science Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura V.","family":"Swant","sequence":"additional","affiliation":[{"name":"INTEGRIS Health Baptist Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marshall T.","family":"Bell","sequence":"additional","affiliation":[{"name":"INTEGRIS Health Baptist Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert S.","family":"Schoaps","sequence":"additional","affiliation":[{"name":"INTEGRIS Health Baptist Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2026,5,5]]},"reference":[{"key":"e_1_3_7_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S2213-2600(18)30506-X"},{"key":"e_1_3_7_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-024-07551-z"},{"key":"e_1_3_7_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0000000000001854"},{"key":"e_1_3_7_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/08850666251352445"},{"key":"e_1_3_7_6_2","doi-asserted-by":"publisher","DOI":"10.1177\/03913988221142904"},{"key":"e_1_3_7_7_2","doi-asserted-by":"publisher","DOI":"10.5772\/63392"},{"key":"e_1_3_7_8_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.jvca.2020.09.117"},{"key":"e_1_3_7_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhlto.2025.100405"},{"key":"e_1_3_7_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/ctr.15447"},{"key":"e_1_3_7_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0000000000002040"},{"key":"e_1_3_7_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/02676591231210457"}],"container-title":["Perfusion"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/02676591251413741","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/02676591251413741","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/02676591251413741","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T10:46:15Z","timestamp":1778150775000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/02676591251413741"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":11,"journal-issue":{"issue":"1_suppl","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["10.1177\/02676591251413741"],"URL":"https:\/\/doi.org\/10.1177\/02676591251413741","relation":{},"ISSN":["0267-6591","1477-111X"],"issn-type":[{"value":"0267-6591","type":"print"},{"value":"1477-111X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5]]}}}