{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:34:43Z","timestamp":1792787683980,"version":"4.5.0"},"reference-count":33,"publisher":"SAGE Publications","issue":"10","license":[{"start":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T00:00:00Z","timestamp":1776729600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"name":"Hallym University Research Fund","award":["2025"],"award-info":[{"award-number":["2025"]}],"id":[{"id":"https:\/\/ror.org\/03sbhge02","id-type":"ROR","asserted-by":"crossref"}]},{"name":"Soonchunhyang University Research Fund","award":["2026"],"award-info":[{"award-number":["2026"]}],"id":[{"id":"https:\/\/ror.org\/03qjsrb10","id-type":"ROR","asserted-by":"crossref"}]},{"name":"National Research Foundation of Korea (NRF) Grant funded by the government of Korea","award":["RS-2024-00449470"],"award-info":[{"award-number":["RS-2024-00449470"]}],"id":[{"id":"https:\/\/ror.org\/013aysd81","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Clin Rehabil"],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:sec>\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>A cross-sectional study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting<\/jats:title>\n                    <jats:p>Patients with burn injuries often present with joint contracture caused by hypertrophic scars. To assess the patient's degree of disability or outcome to rehabilitation treatment, various objective assessment tools are used, such as a standard goniometer, which is often used for measuring joint range of motion; however, measurements using a handheld goniometer may have a large margin of error depending on the therapist's experience. Herein, the reliability and validity of a novel marker-based system were investigated for evaluating joint range of motion in patients with burn injuries.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Participants<\/jats:title>\n                    <jats:p>In total, 48 participants with joint contractures in the shoulder, elbow, and wrist owing to hypertrophic scars after thermal injury were enrolled.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Intervention<\/jats:title>\n                    <jats:p>Upper extremity joint range of motion was measured using a goniometer and optical motion capture system (Session 1), followed by remeasurement 2 days later (Session 2).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main measures<\/jats:title>\n                    <jats:p>Twenty-two reflective markers were attached to the upper limbs, and motion analysis was measured using eight infrared cameras.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>No statistical differences were detected between the range of motion values measured using the two methods. The measurements based on the optical motion capture system showed excellent intra-rater reliability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The findings of this study highlight the value of the motion capture system as a tool to objectively evaluate the joint range of motion in patients with contractures caused by burns.<\/jats:p>\n                    <jats:p>This study was registered at ClinicalTrials.gov (Identifier: NCT05881876).<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/02692155261432011","type":"journal-article","created":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T12:59:09Z","timestamp":1776776349000},"page":"1366-1376","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Determining the reliability and validity of a new method for measuring upper extremity joint range of motion in patients with burn injury using a tracking system"],"prefix":"10.1177","volume":"40","author":[{"given":"Seung Yeol","family":"Lee","sequence":"first","affiliation":[{"name":"Soonchunhyang University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ya Xin","family":"Zheng","sequence":"additional","affiliation":[{"name":"Hallym University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheong Hoon","family":"Seo","sequence":"additional","affiliation":[{"name":"Hallym University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoon Soo","family":"Cho","sequence":"additional","affiliation":[{"name":"Hallym University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-6440-175X","authenticated-orcid":false,"given":"Jisu","family":"Seo","sequence":"additional","affiliation":[{"name":"Hallym University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ye Dam","family":"Bae","sequence":"additional","affiliation":[{"name":"Hallym University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jisu","family":"Yoon","sequence":"additional","affiliation":[{"name":"VectorBio Co., Ltd, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyungseok","family":"Byun","sequence":"additional","affiliation":[{"name":"VectorBio Co., Ltd, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1199-7278","authenticated-orcid":false,"given":"So Young","family":"Joo","sequence":"additional","affiliation":[{"name":"Hallym University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,4,21]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.burns.2022.05.005"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2019.11.017"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0313287"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.burns.2023.09.014"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1093\/jbcr\/iraa110"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.burns.2025.107677"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.burns.2020.12.024"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.burns.2019.05.003"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1093\/jbcr\/irab047"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.burns.2021.01.003"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1080\/19371918.2021.1997862"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.burns.2025.107461"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2023.03.018"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1093\/jbcr\/irx027"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1155\/bn\/6006064"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-9457(01)00050-1"},{"key":"e_1_3_3_18_2","first-page":"1","article-title":"Validation of a wearable low-cost EMG prototype device to support knee extension exercises","volume":"2025","author":"Liu Z","year":"2025","unstructured":"Liu Z, Mumuni I, Tehrany R, et al. Validation of a wearable low-cost EMG prototype device to support knee extension exercises. Annu Int Conf IEEE Eng Med Biol Soc 2025; 2025: 1\u20137.","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2004.05.042"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2018.03.009"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.3390\/s18071980"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.62713\/aic.4394"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1093\/jbcr\/irz038"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1093\/jbcr\/irz174"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.burns.2019.02.016"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1002\/lsm.23201"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1097\/BCR.0b013e3181f9354f"},{"key":"e_1_3_3_28_2","first-page":"1","article-title":"Validity, reliability and accuracy of inertial measurement units (IMUs) to measure angles: application in swimming","volume":"23","author":"Guignard B","year":"2021","unstructured":"Guignard B, Ayad O, Baillet H, et al. Validity, reliability and accuracy of inertial measurement units (IMUs) to measure angles: application in swimming. Sports Biomech 2021; 23: 1\u201333.","journal-title":"Sports Biomech"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.3390\/s20164539"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2024.104142"},{"key":"e_1_3_3_31_2","article-title":"A comprehensive analysis of the validity and reliability of the perception neuron studio for upper-body motion capture","volume":"22","author":"Wu Y","year":"2022","unstructured":"Wu Y, Tao K, Chen Q, et al. A comprehensive analysis of the validity and reliability of the perception neuron studio for upper-body motion capture. Sensors (Basel) 2022; 22.","journal-title":"Sensors (Basel)"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0213064"},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.1123\/jab.2016-0120"},{"key":"e_1_3_3_34_2","doi-asserted-by":"publisher","DOI":"10.3390\/s20226452"}],"container-title":["Clinical Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/02692155261432011","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/02692155261432011","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/02692155261432011","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T06:17:03Z","timestamp":1790921823000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/02692155261432011"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,21]]},"references-count":33,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["10.1177\/02692155261432011"],"URL":"https:\/\/doi.org\/10.1177\/02692155261432011","relation":{},"ISSN":["0269-2155","1477-0873"],"issn-type":[{"value":"0269-2155","type":"print"},{"value":"1477-0873","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,21]]}}}