{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,12]],"date-time":"2026-05-12T16:56:43Z","timestamp":1778605003824,"version":"3.51.4"},"reference-count":18,"publisher":"SAGE Publications","issue":"5-6","license":[{"start":{"date-parts":[[2006,5,1]],"date-time":"2006-05-01T00:00:00Z","timestamp":1146441600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The International Journal of Robotics Research"],"published-print":{"date-parts":[[2006,5]]},"abstract":"<jats:p>This paper proposes a Non-Contact Stiffness Imager that can enhance the definition of a stiff point by imparting a fluid force to the environment. The force is applied to the environment at a local point and displacement of the environment is measured in the surrounding area. We first demonstrate the basic idea by utilizing an experimental system composed of an air supply system and a scanning type line laser sensor. Then we apply the idea to an endoscope camera capable of detecting a stiff point.<\/jats:p>","DOI":"10.1177\/0278364906065826","type":"journal-article","created":{"date-parts":[[2006,5,9]],"date-time":"2006-05-09T07:45:09Z","timestamp":1147160709000},"page":"537-549","source":"Crossref","is-referenced-by-count":42,"title":["Non-Contact Stiffness Imager"],"prefix":"10.1177","volume":"25","author":[{"given":"Tomohiro","family":"Kawahara","sequence":"first","affiliation":[{"name":"Graduate School of Engineering, Hiroshima University, Higashi-Hiroshima                         739-8527, JAPAN,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinji","family":"Tanaka","sequence":"additional","affiliation":[{"name":"Graduate School of Biomedical Science, Hiroshima University Hospital,                         Hiroshima 734-8551, JAPAN,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Makoto","family":"Kaneko","sequence":"additional","affiliation":[{"name":"Graduate School of Engineering, Hiroshima University, Higashi-Hiroshima                         739-8527, JAPAN,"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2006,5,1]]},"reference":[{"key":"atypb1","unstructured":"Arimoto, S., Kawamura, S., and Han, H. Y. 1998. Tactile sensing and stiffness control with multifingered hands . Proceedings of IEEE International Conference on Robotics and Automation, pp. 1435-1440 ."},{"key":"atypb2","doi-asserted-by":"publisher","DOI":"10.1089\/end.2005.19.940"},{"key":"atypb3","unstructured":"Fujimura, T.et al. 2003. The development for new no-contact type measurement of skin elasticity . Proceedings of the 53th SCCJ, (in Japanese) pp. 6-9 ."},{"key":"atypb4","doi-asserted-by":"publisher","DOI":"10.1080\/08998280.2005.11928089"},{"key":"atypb5","doi-asserted-by":"publisher","DOI":"10.1007\/BF00355685"},{"key":"atypb6","doi-asserted-by":"crossref","unstructured":"Ikuta, K., Tsukamoto, M., and Hirose, S. 1998. Shape memory alloy servo actuator system with electric resistance feedback and application for active endoscope . Proceedings of the IEEE International Conference on Robotics and Automation, pp. 427-430 .","DOI":"10.1109\/ROBOT.1988.12085"},{"key":"atypb7","doi-asserted-by":"crossref","unstructured":"Kaneko, M.et al. 2003. Touching stomach by air . Proceedings of IEEE International Conference on Robotics and Automation, pp. 664-669 .","DOI":"10.1109\/ROBOT.2003.1241670"},{"key":"atypb8","doi-asserted-by":"crossref","unstructured":"Kaneko, M. and Kawahara, T. 2004. Co-axis type Non-Contact Impedance Sensor . Proceedings of the IEEE International Conference on Robotics and Automation, pp. 709-714 .","DOI":"10.1109\/ROBOT.2004.1307232"},{"key":"atypb9","doi-asserted-by":"crossref","unstructured":"Kaneko, M., Kawahara, T., and Tanaka, S. 2004a. Non-contact stiffness imager . Proceedings of IEEE International Conference on Robotics and Automation, pp. 1562-1567 .","DOI":"10.1109\/ROBOT.2004.1308046"},{"key":"atypb10","unstructured":"Kaneko, M., Kawahara, T., and Tanaka, S. 2004b. Stiffness imager . Proceedings of the 9th International Symposium on Experimental Robotics, ID-161 ."},{"key":"atypb11","doi-asserted-by":"crossref","unstructured":"Kawahara, T. and Kaneko, M. 2005. Non-contact stiffness imager for medical application . Proceedings of IEEE International Conference on Information Acquisition, pp. 350-355 .","DOI":"10.1109\/ICIA.2005.1635111"},{"key":"atypb12","unstructured":"Kinoshita, O. 2002. Trial production of firmness evaluation device for cherry tomato . Journal of Kyushu Branch of JSAM, (in Japanese) 51: 5-9 ."},{"key":"atypb13","unstructured":"Nidek. http:\/\/www.nidek.com\/nt.html, Non-Contact Tonometer, NIDEC Co., Ltd."},{"key":"atypb14","doi-asserted-by":"crossref","unstructured":"Simaan, N., Taylor, R., and Flint, P. 2004. A dexterous system for laryngeal surgery . Proceedings of the IEEE International Conference on Robotics and Automation, pp. 351-357 .","DOI":"10.1109\/ROBOT.2004.1307175"},{"key":"atypb15","doi-asserted-by":"crossref","unstructured":"Son, J. S. and Howe, R. D. 1996. Tactile sensing and stiffness control with multifingered hands . Proceedings of IEEE International Conference on Robotics and Automation, pp. 3228-3233 .","DOI":"10.1109\/ROBOT.1996.509204"},{"key":"atypb16","doi-asserted-by":"crossref","unstructured":"Takemura, K., Harada, D., and Maeno, T. 2002. Development of a master-slave system for active endoscope using a multi-DOF ultrasonic motor . Transactions on Control, Automation, and Systems Engineering 4(1): 17-22 .","DOI":"10.1299\/jsmermd.2001.17_3"},{"key":"atypb17","doi-asserted-by":"publisher","DOI":"10.1007\/BF00199890"},{"key":"atypb18","unstructured":"Yamasaki, H. and Shinoda, H. 1990. Noncontact tactile sensor for surface hardness evaluation . Proceedings of 1st International Symposium on Measurement and Control in Robotics, pp. I1.3.1-I1.3.5 ."}],"container-title":["The International Journal of Robotics Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0278364906065826","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0278364906065826","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T10:15:47Z","timestamp":1777457747000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0278364906065826"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,5]]},"references-count":18,"journal-issue":{"issue":"5-6","published-print":{"date-parts":[[2006,5]]}},"alternative-id":["10.1177\/0278364906065826"],"URL":"https:\/\/doi.org\/10.1177\/0278364906065826","relation":{},"ISSN":["0278-3649","1741-3176"],"issn-type":[{"value":"0278-3649","type":"print"},{"value":"1741-3176","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,5]]}}}