{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T09:58:23Z","timestamp":1777715903578,"version":"3.51.4"},"reference-count":19,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2009,5,19]],"date-time":"2009-05-19T00:00:00Z","timestamp":1242691200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The International Journal of Robotics Research"],"published-print":{"date-parts":[[2010,1]]},"abstract":"<jats:p>Pneumatic actuators are attractive for robotic rehabilitation applications because they are lightweight, powerful, and compliant, but their control has historically been difficult, limiting their use. In this paper we present the pneumatic control system developed for Pneu-WREX: a pneumatically actuated, upper extremity orthosis for rehabilitation after stroke. The developed pneumatic control system combines several novel components to make the entire system stable, reliable, and backdrivable. These components, which are described in this paper, include: (1) a unique two-valve force control subsystem that keeps chamber pressure low (to reduce friction and energy consumption) and adaptively compensates for leakage; (2) a new servovalve characterization approach that uses experimentally measured data in a combined non-linear and least-squares regression to obtain a linear relationship between mass flow and valve voltage; and (3) a new approach to state estimation using accelerometers and a Kalman filter to obtain clean signals for use in a non-linear adaptive feedback control law. Experimental testing of the device demonstrates the efficacy of the developed pneumatic control system.<\/jats:p>","DOI":"10.1177\/0278364909103787","type":"journal-article","created":{"date-parts":[[2009,5,19]],"date-time":"2009-05-19T22:09:33Z","timestamp":1242770973000},"page":"23-38","source":"Crossref","is-referenced-by-count":39,"title":["Pneumatic Control of Robots for Rehabilitation"],"prefix":"10.1177","volume":"29","author":[{"given":"Eric T.","family":"Wolbrecht","sequence":"first","affiliation":[{"name":"Mechanical Engineering Department, University of Idaho, Moscow, ID 83844, USA,"}]},{"given":"David J.","family":"Reinkensmeyer","sequence":"additional","affiliation":[{"name":"Mechanical and Aerospace and Biomedical Engineering Departments, University of California, Irvine, CA 92697, USA,"}]},{"given":"James E.","family":"Bobrow","sequence":"additional","affiliation":[{"name":"Mechanical and Aerospace Engineering Department, University of California, Irvine, CA 92697, USA,"}]}],"member":"179","published-online":{"date-parts":[[2009,5,19]]},"reference":[{"key":"atypb1","volume-title":"Proceedings 2003 IEEE\/ASME International Conference on Advanced Intelligent Mechatronics","author":"Al-Dakkan, K.A."},{"key":"atypb2","doi-asserted-by":"publisher","DOI":"10.1109\/70.720349"},{"key":"atypb3","doi-asserted-by":"publisher","DOI":"10.1115\/1.2168473"},{"key":"atypb4","volume-title":"Proceedings 2004 IEEE International Conference on Robotics and Automation","author":"Granosik, G."},{"key":"atypb5","volume-title":"27th Annual International Conference of the Engineering in Medicine and Biology Society","author":"He, J."},{"key":"atypb6","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2006.875571"},{"key":"atypb7","volume-title":"A Mathematical Introduction to Robotic Manipulation","author":"Murray, R.M.","year":"1994"},{"key":"atypb8","volume-title":"Lecture Notes in Control and Information Sciences","author":"Rahman, T."},{"key":"atypb9","doi-asserted-by":"publisher","DOI":"10.1682\/JRRD.2005.04.0073"},{"key":"atypb10","doi-asserted-by":"publisher","DOI":"10.1115\/1.1286336"},{"key":"atypb11","doi-asserted-by":"publisher","DOI":"10.1115\/1.1286366"},{"key":"atypb12","volume-title":"9th International Conference on Rehabilitation Robotics, 2005 (ICORR 2005)","author":"Sanchez, R.J."},{"key":"atypb13","first-page":"195","volume":"17","author":"Sanville, F.E.","year":"1971","journal-title":"Hydraulic Pneumatic Power"},{"key":"atypb14","first-page":"233","volume":"78","author":"Shearer, J.L.","year":"1956","journal-title":"Transactions of the ASME"},{"key":"atypb15","volume-title":"Applied Nonlinear Control","author":"Slotine, J.J.E.","year":"1991"},{"key":"atypb16","doi-asserted-by":"publisher","DOI":"10.1115\/1.2801298"},{"key":"atypb17","volume-title":"28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2006 (EMBS \u201906)","author":"Wolbrecht, E.T."},{"key":"atypb18","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2008.918389"},{"key":"atypb19","doi-asserted-by":"publisher","DOI":"10.1016\/S0967-0661(03)00104-7"}],"container-title":["The International Journal of Robotics Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0278364909103787","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0278364909103787","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T10:16:49Z","timestamp":1777457809000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0278364909103787"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,5,19]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,1]]}},"alternative-id":["10.1177\/0278364909103787"],"URL":"https:\/\/doi.org\/10.1177\/0278364909103787","relation":{},"ISSN":["0278-3649","1741-3176"],"issn-type":[{"value":"0278-3649","type":"print"},{"value":"1741-3176","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,5,19]]}}}