{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T23:57:37Z","timestamp":1777507057847,"version":"3.51.4"},"reference-count":30,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2022,3,15]],"date-time":"2022-03-15T00:00:00Z","timestamp":1647302400000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100006041","name":"Innovate UK","doi-asserted-by":"publisher","award":["Grant number 83706"],"award-info":[{"award-number":["Grant number 83706"]}],"id":[{"id":"10.13039\/501100006041","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Acta Radiol"],"published-print":{"date-parts":[[2023,2]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Mobile chest X-ray (CXR) scans are performed within intensive treatment units (ITU) without anti-scatter grids for confirming tube and line hardware placement. Assessment is therefore challenging due to degraded subject contrast resulting from scatter.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the efficacy of a software scatter correction method (commercially named Trueview) for enhanced hardware visualization and diagnostic quality in the ITU setting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and Methods<\/jats:title>\n                    <jats:p>A total of 30 CXR scans were processed using Trueview and compared with standard original equipment manufacturer (OEM) images via observer scoring study involving two radiology and four ITU doctors to compare visualization of tubes and lines. Results were analyzed to determine observer preference and likelihood of diagnostic quality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Reviewers were more likely to score Trueview higher than OEM for mediastinal structures, bones, retrocardiac region, tube visibility, and tube safety ( P\u2009 &lt;\u20090 .01). Visual grading characteristic analysis suggested a clinical preference for Trueview compared with OEM for mediastinal structures (area under the visual grading characteristic curve [AUC\n                      <jats:sub>VGC<\/jats:sub>\n                      ]\u2009=\u20090.60, 95% confidence interval [CI] = 0.55\u20130.65), bones (AUC\n                      <jats:sub>VGC<\/jats:sub>\n                      \u2009=\u20090.61, 95% CI = 0.55\u20130.66), retrocardiac region (AUC\n                      <jats:sub>VGC<\/jats:sub>\n                      \u2009=\u20090.64, 95% CI = 0.59\u20130.69), tube visibility (AUC\n                      <jats:sub>VGC<\/jats:sub>\n                      \u2009=\u20090.65, 95% CI = 0.60\u20130.70), and tube safety (AUC\n                      <jats:sub>VGC<\/jats:sub>\n                      \u2009=\u20090.68, 95% CI = 0.64\u20130.73). Reviewers were indifferent to visualization of the lung fields (AUC\n                      <jats:sub>VGC<\/jats:sub>\n                      \u2009=\u20090.49, 95% CI = 0.44\u20130.55). Registrars (3\/6 reviewers) were indifferent to the mediastinal structure regions (AUC\n                      <jats:sub>VGC<\/jats:sub>\n                      \u2009=\u20090.54, 95% CI = 0.47\u20130.62).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Reviewers were more confident in identifying the placement and safety of tubes and lines when reviewing Trueview images than they were when reviewing OEM.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/02841851221087631","type":"journal-article","created":{"date-parts":[[2022,3,16]],"date-time":"2022-03-16T02:48:58Z","timestamp":1647398938000},"page":"563-571","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":6,"title":["Enhanced visualization of mobile chest X-ray images in the intensive care setting using software scatter correction"],"prefix":"10.1177","volume":"64","author":[{"given":"Harry","family":"Targett","sequence":"first","affiliation":[{"name":"Department of Clinical Radiology, South Tees Hospitals NHS Foundation Trust, The James Cook University Hospital, Rd, Middlesbrough, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominic","family":"Hutchinson","sequence":"additional","affiliation":[{"name":"Department of Critical Care, South Tees Hospitals NHS Foundation Trust, The James Cook University Hospital, Middlesbrough, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard","family":"Hartley","sequence":"additional","affiliation":[{"name":"Department of Clinical Radiology, South Tees Hospitals NHS Foundation Trust, The James Cook University Hospital, Rd, Middlesbrough, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3180-8665","authenticated-orcid":false,"given":"Richard","family":"McWilliam","sequence":"additional","affiliation":[{"name":"IBEX Innovations Ltd., Explorer 2, Sedgefield, 3FF, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ben","family":"Lopez","sequence":"additional","affiliation":[{"name":"IBEX Innovations Ltd., Explorer 2, Sedgefield, 3FF, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ben","family":"Crone","sequence":"additional","affiliation":[{"name":"IBEX Innovations Ltd., Explorer 2, Sedgefield, 3FF, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephen","family":"Bonner","sequence":"additional","affiliation":[{"name":"Department of Critical Care, South Tees Hospitals NHS Foundation Trust, The James Cook University Hospital, Middlesbrough, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2022,3,15]]},"reference":[{"key":"bibr1-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1016\/j.ccc.2007.06.001"},{"key":"bibr2-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1016\/0899-7071(95)00097-6"},{"key":"bibr3-02841851221087631","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.01712"},{"key":"bibr4-02841851221087631","author":"Musanhu E","journal-title":"Poster presented at: European Congress of Radiology"},{"key":"bibr5-02841851221087631","doi-asserted-by":"publisher","DOI":"10.4103\/ijri.IJRI_329_19"},{"key":"bibr6-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.d2586"},{"key":"bibr7-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.f6570"},{"key":"bibr8-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1118\/1.597767"},{"key":"bibr9-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1148\/radiographics.12.1.1734456"},{"key":"bibr10-02841851221087631","author":"Mentrup D","journal-title":"Poster presented at: European Congress of Radiology"},{"key":"bibr11-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1177\/0284185119878348"},{"key":"bibr12-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncw031"},{"key":"bibr13-02841851221087631","doi-asserted-by":"publisher","DOI":"10.3348\/kjr.2018.19.3.526"},{"key":"bibr14-02841851221087631","first-page":"75","volume-title":"Proceedings of 2012 IEEE-EMBS international conference on biomedical and health informatics","volume":"2012","author":"Wang L"},{"key":"bibr15-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1118\/1.2148916"},{"key":"bibr16-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncv432"},{"key":"bibr17-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/55\/22\/007"},{"key":"bibr18-02841851221087631","first-page":"1","volume-title":"2007 IEEE instrumentation & measurement technology conference IMTC","volume":"2007","author":"Chen Y"},{"key":"bibr19-02841851221087631","unstructured":"Lopez BT. A Bayes Linear Approach to Making Inferences from X-rays [dissertation]. Durham: Durham University, 2018."},{"key":"bibr20-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1148\/radiographics.11.2.2028065"},{"key":"bibr21-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1109\/LSP.2016.2580600"},{"key":"bibr22-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-12-374457-9.00011-1"},{"key":"bibr23-02841851221087631","first-page":"551","volume-title":"Proc. SPIE 2167, medical imaging 1994: image processing","volume":"1994","author":"Vuylsteke P"},{"key":"bibr24-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/nch550"},{"key":"bibr25-02841851221087631","first-page":"69170X","volume":"2008","author":"B\u00e5th M","journal-title":"Proc. SPIE 6917, medical imaging 2008: image perception, observer performance, and technology assessment"},{"key":"bibr26-02841851221087631","doi-asserted-by":"publisher","DOI":"10.4097\/kjae.2015.68.6.540"},{"key":"bibr27-02841851221087631","first-page":"171","volume-title":"Institute of mathematical statistics","volume":"1","author":"Wilcoxon F","year":"1970"},{"key":"bibr28-02841851221087631","doi-asserted-by":"publisher","DOI":"10.1259\/bjr\/35012658"},{"key":"bibr29-02841851221087631","volume-title":"An introduction to bootstrap methods with applications to R. Hoboken","author":"Chernick MR","year":"2014"},{"key":"bibr30-02841851221087631","unstructured":"R Core Team. R: A language and environment for statistical computing. 2021. Available at: https:\/\/www.R-project.org\/ (last accessed August 2021)."}],"container-title":["Acta Radiologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/02841851221087631","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/02841851221087631","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/02841851221087631","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T15:27:50Z","timestamp":1777390070000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/02841851221087631"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,15]]},"references-count":30,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023,2]]}},"alternative-id":["10.1177\/02841851221087631"],"URL":"https:\/\/doi.org\/10.1177\/02841851221087631","relation":{},"ISSN":["0284-1851","1600-0455"],"issn-type":[{"value":"0284-1851","type":"print"},{"value":"1600-0455","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,15]]}}}