{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T19:01:52Z","timestamp":1785006112622,"version":"3.55.0"},"reference-count":31,"publisher":"SAGE Publications","issue":"10","license":[{"start":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T00:00:00Z","timestamp":1749600000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Acta Radiol"],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Liver iron overload is the most common cause of magnetic resonance elastography (MRE) failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To determine a threshold of R2*, a surrogate of liver iron concentration (LIC), which predicts the failure of liver MRE for either 2D gradient\u2013recalled echo (GRE) or spin-echo echo-planar imaging (SE-EPI) MRE sequence at 3 T.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and Methods<\/jats:title>\n                    <jats:p>This single\u2013center retrospective study included 247 patients who underwent GRE MRE, SE-EPI MRE sequences for fibrosis evaluation and 2D multi-echo GRE sequence for R2* quantification using MRQuantif software. The ability of R2* to predict the failed MRE related to liver iron accumulation was estimated by the area under the receiver operating characteristic curve (AUC).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      After excluding 26 exams for technical failure, we evaluated 221 patients (52 women; mean age = 56\u2009\u00b1\u200913) with R2* values in the range of 37\u20131665\u2005s\n                      <jats:sup>\u22121<\/jats:sup>\n                      . The iron\u2013related failure rates of GRE MRE and SE-EPI MRE were 62.9% (139\/221) and 10.0% (22\/221), respectively. The best cutoff of R2* to predict failure exam due to liver iron deposition with GRE MRE was 101\u2005s\n                      <jats:sup>\u22121<\/jats:sup>\n                      with a sensitivity of 79.1% and specificity of 97.6% (AUC = 0.97; 95% confidence interval [CI] = 0.95\u20130.99). This cutoff for SE-EPI MRE was 289\u2005s\n                      <jats:sup>\u22121<\/jats:sup>\n                      with a sensitivity of 82.8% and specificity of 99.5% (AUC = 0.89; 95% CI = 0.78\u20131).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Liver R2* is a good predictor of MRE examination failure related to iron deposition for MRE at 3 T.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/02841851251344464","type":"journal-article","created":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T04:12:11Z","timestamp":1749615131000},"page":"1070-1076","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":4,"title":["Liver R2* threshold to predict the failure of MR elastography at 3T: SE-EPI versus GRE sequences"],"prefix":"10.1177","volume":"66","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7025-5119","authenticated-orcid":false,"given":"Thi Hien Trang","family":"Chau","sequence":"first","affiliation":[{"name":"NUMECAN, INSERM U1099, Rennes University Hospital, Rennes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elise","family":"Bannier","sequence":"additional","affiliation":[{"name":"Department of Radiology, Rennes University Hospital, Rennes, France"},{"name":"INRIA, CNRS, INSERM, IRISA, EMPENN ERL U1228, University of Rennes, Rennes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edouard","family":"Bardou-Jacquet","sequence":"additional","affiliation":[{"name":"Univ Rennes, CHU Rennes, National Reference Center for Hemochromatosis and Iron Metabolism Disorders, INSERM CIC1414, Rennes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yves","family":"Gandon","sequence":"additional","affiliation":[{"name":"NUMECAN, INSERM U1099, Rennes University Hospital, Rennes, France"},{"name":"Department of Radiology, Rennes University Hospital, Rennes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2025,6,11]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00261-020-02656-7"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhep.2012.12.005"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.12659\/MSM.896494"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.lpm.2017.05.036"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/hep.24330"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/bjh.17839"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.mric.2020.03.001"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2016160863"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-017-5149-5"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.26918"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00261-019-01932-5"},{"key":"e_1_3_3_13_2","article-title":"Feasibility and agreement of stiffness measurements using gradient-echo and spin-echo MR elastography sequences in unselected patients undergoing liver MRI","volume":"91","author":"Cunha GM","unstructured":"Cunha GM, Glaser KJ, Bergman A, et al. Feasibility and agreement of stiffness measurements using gradient-echo and spin-echo MR elastography sequences in unselected patients undergoing liver MRI. Br J Radiol 2018;91: 20180126.","journal-title":"Br J Radiol"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-017-4781-4"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25818"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.21037\/qims.2019.05.13"},{"key":"e_1_3_3_17_2","doi-asserted-by":"crossref","unstructured":"d\u2019Assignies G Paisant A Bardou-Jacquet E et al. Non-invasive measurement of liver iron concentration using 3-Tesla magnetic resonance imaging: validation against biopsy. Eur Radiol 2018;28:2022\u20132030.","DOI":"10.1007\/s00330-017-5106-3"},{"key":"e_1_3_3_18_2","doi-asserted-by":"crossref","unstructured":"Paisant A d\u2019Assignies G Bannier E et al. MRI for the measurement of liver iron content and for the diagnosis and follow-up of iron overload disorders. Presse M\u00e9dicale 2017;46:e279\u2013e287.","DOI":"10.1016\/j.lpm.2017.10.008"},{"key":"e_1_3_3_19_2","doi-asserted-by":"crossref","unstructured":"Reeder SB Yokoo T Fran\u00e7a M et al. Quantification of liver iron overload with MRI: review and guidelines from the ESGAR and SAR. Radiology 2023;307:e221856.","DOI":"10.1148\/radiol.221856"},{"key":"e_1_3_3_20_2","unstructured":"QIBA MR Biomarker Committee (2022) MR Elastography of the Liver Quantitative Imaging Biomarkers Alliance. Profile Stage: Technically Confirmed. February 14 2022. http:\/\/qibawiki.rsna.org\/index.php\/Profiles (accessed 20 December 2023)."},{"key":"e_1_3_3_21_2","first-page":"1326\u20131335","article-title":"Technical success and reliability of magnetic resonance elastography in patients with hepatic iron overload","author":"Liu J","unstructured":"Liu J, Huang M, Zhang Y, et al. Technical success and reliability of magnetic resonance elastography in patients with hepatic iron overload. Acad Radiol 2024;31:1326\u20131335.","journal-title":"Acad Radiol"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00261-018-1723-9"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.13104\/imri.2019.23.3.251"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cgh.2014.09.046"},{"key":"e_1_3_3_25_2","article-title":"Magnetic resonance elastography of the liver: everything you need to know to get started","author":"Pepin KM","unstructured":"Pepin KM, Welle CL, Guglielmo FF, et al. Magnetic resonance elastography of the liver: everything you need to know to get started. Abdom Radiol (NY) 2022;47:94\u2013114.","journal-title":"Abdom Radiol (NY)"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2015142141"},{"key":"e_1_3_3_27_2","first-page":"19","article-title":"MR Elastography \u2013 Pearls and Pitfalls","volume":"71","author":"Bolster B","year":"2018","unstructured":"Bolster BJr, Jin N, Kannengiesser S. MR Elastography \u2013 Pearls and Pitfalls. Magnetom Flash 2018; 71:19\u201323.","journal-title":"Magnetom Flash"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.17.19288"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2016160153"},{"key":"e_1_3_3_30_2","article-title":"Limits of fat quantification in the presence of iron overload","author":"Colgan TJ","unstructured":"Colgan TJ, Zhao R, Roberts NT, et al. Limits of fat quantification in the presence of iron overload. J Magn Reson Imaging 2021;54:1166\u20131174.","journal-title":"J Magn Reson Imaging"},{"key":"e_1_3_3_31_2","doi-asserted-by":"crossref","unstructured":"Orcel T Chau HT Turlin B et al. Evaluation of proton density fat fraction (PDFF) obtained from a vendor-neutral MRI sequence and MRQuantif software. Eur Radiol 2023;33:8999\u20139009.","DOI":"10.1007\/s00330-023-09798-4"},{"key":"e_1_3_3_32_2","doi-asserted-by":"crossref","unstructured":"Chen J Allen AM Therneau TM et al. Liver stiffness measurement by magnetic resonance elastography is not affected by hepatic steatosis. Eur Radiol 2022;32:950\u2013958.","DOI":"10.1007\/s00330-021-08225-w"}],"container-title":["Acta Radiologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/02841851251344464","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/02841851251344464","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/02841851251344464","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T15:34:41Z","timestamp":1777390481000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/02841851251344464"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,11]]},"references-count":31,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1177\/02841851251344464"],"URL":"https:\/\/doi.org\/10.1177\/02841851251344464","relation":{},"ISSN":["0284-1851","1600-0455"],"issn-type":[{"value":"0284-1851","type":"print"},{"value":"1600-0455","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,11]]}}}