{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T00:37:37Z","timestamp":1777509457297,"version":"3.51.4"},"reference-count":9,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T00:00:00Z","timestamp":1761523200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"name":"Future Medicine 20*30 Project of the Samsung Medical Center","award":["SMX1240781"],"award-info":[{"award-number":["SMX1240781"]}]},{"name":"The Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health Welfare, Republic of Korea","award":["HR21C0885"],"award-info":[{"award-number":["HR21C0885"]}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Acta Radiol"],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Automatic exposure control (AEC) devices are necessary to reduce the radiation dose and enhance image quality in radiography. However, AEC devices are not being used in portable X-ray systems due to technical issues.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the radiation dose and image quality of a new AEC for a wireless portable X-ray system compared to the standard fixed radiation dose of manual controls in chest radiography.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and Methods<\/jats:title>\n                    <jats:p>This retrospective analysis evaluated the performance of a portable X-ray system equipped with software-based AEC on anteroposterior chest radiographs. A quantitative evaluation comparing the manual and AEC groups was conducted to ascertain the exposure index (EI) and dose-area product (DAP). We performed observer-based analysis of image quality for lowest exposure and average exposure images in the manual and AEC groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Overall, 2093 examinations were conducted in 467 patients. AEC yielded a statistically significant reduction in the DAP (AEC: 1.64 dGycm\n                      <jats:sup>2<\/jats:sup>\n                      ; manual: 1.99 dGycm\n                      <jats:sup>2<\/jats:sup>\n                      ) and EI (AEC: 266; manual: 393) compared to manual control (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&lt;0.001). Evaluation of the average and low exposure images revealed that the DAP and EI were consistently lower in the AEC group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&lt;0.01). Observer-based analysis of the lowest exposure images revealed that AEC yielded a statistically significant higher score compared to manual control (12.5 manual, 13.4 AEC;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&lt;0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>AEC within a wireless portable X-ray system improves subjective image quality while reducing radiation exposure, as substantiated by quantitative and qualitative metrics.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/02841851251387448","type":"journal-article","created":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T17:17:08Z","timestamp":1761585428000},"page":"60-66","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Efficacy of a new detector automatic exposure control in portable anteroposterior chest radiography: a retrospective examination of radiation dose optimization and image quality"],"prefix":"10.1177","volume":"67","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5960-0719","authenticated-orcid":false,"given":"Yoon Ki","family":"Cha","sequence":"first","affiliation":[{"name":"Sungkyunkwan University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jung Han","family":"Woo","sequence":"additional","affiliation":[{"name":"Chung-Ang University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong Hyuk","family":"Kim","sequence":"additional","affiliation":[{"name":"Health &amp; Medical Equipment Business, Samsung Electronics Co., Ltd, Seoul, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sanguk","family":"Kim","sequence":"additional","affiliation":[{"name":"Health &amp; Medical Equipment Business, Samsung Electronics Co., Ltd, Seoul, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong Hun","family":"Lee","sequence":"additional","affiliation":[{"name":"Health &amp; Medical Equipment Business, Samsung Electronics Co., Ltd, Seoul, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6271-3343","authenticated-orcid":false,"given":"Myung Jin","family":"Chung","sequence":"additional","affiliation":[{"name":"Sungkyunkwan University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2025,10,27]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/51\/21\/006"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.145.3.7146417"},{"key":"e_1_3_2_4_2","unstructured":"International Electrotechnical Commission. Medical electrical equipment\u2013Exposure index of digital X-ray imaging systems-Part 1: Definitions and requirements for general radiography. IEC Geneva Switzerland BS EN 62494-1. Available at: http:\/\/higiene.unex.es\/Bibliogr\/ISO_BS_USDA\/ISO_BS\/BS%20EN\/BS%20EN%2062494-1-2008.pdf (2008 accessed 1 October 2024)."},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-010-1954-6"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-003-1971-z"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics11101932"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-010-1951-9"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2023.e20760"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph18105203"}],"container-title":["Acta Radiologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/02841851251387448","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/02841851251387448","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/02841851251387448","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T15:34:50Z","timestamp":1777390490000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/02841851251387448"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,27]]},"references-count":9,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["10.1177\/02841851251387448"],"URL":"https:\/\/doi.org\/10.1177\/02841851251387448","relation":{},"ISSN":["0284-1851","1600-0455"],"issn-type":[{"value":"0284-1851","type":"print"},{"value":"1600-0455","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,27]]}}}