{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T13:33:56Z","timestamp":1777469636882,"version":"3.51.4"},"reference-count":38,"publisher":"SAGE Publications","issue":"3P2","license":[{"start":{"date-parts":[[1996,5,1]],"date-time":"1996-05-01T00:00:00Z","timestamp":830908800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Radiol"],"published-print":{"date-parts":[[1996,5]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the performances of 4 imaging systems in the diagnostic radiology of the chest: an asymmetric screen-film combination (a-SFC); a conventional screen-film combination of speed class 200 (SFC); a screen-film combination of speed class 200 with an aluminium lung filter; and digital luminescence radiographs (DLR).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and Methods:<\/jats:title>\n                    <jats:p>Object detectability studies were carried out using an anthropomorphic chest phantom. The images were obtained under standard exposure conditions at 125 kVp. The detection performance of the various systems was evaluated by receiver operating characteristic (ROC) analysis on the basis of a total of 12 240 observations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>In the overall evaluation the a-SFC and the SFC plus lung filter received equally high ratings of 0.878\u00b10.018 and 0.860\u00b10.21, respectively (p&gt;0.05). There was no significant difference between the 200-speed SFC and the storage phosphor radiographs. In the mediastinum all the tested systems were clearly superior to the 200-speed SFC (p&lt;0.05) while in the lung fields the 200-speed SFC received a high rating of 0.866\u00b10.026. The a-SFC had slight advantages over the SFC plus lung filter and the 2 digital imaging modes (p&gt;0.05).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The a-SFC and the digital luminescence radiographs provide a significant gain in diagnostic information in the mediastinum without diminishing detail detectability in the lung fields and without additional radiation exposure.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/02841851960373p282","type":"journal-article","created":{"date-parts":[[2015,6,11]],"date-time":"2015-06-11T06:26:50Z","timestamp":1434004010000},"page":"847-854","source":"Crossref","is-referenced-by-count":0,"title":["Roc-Analysisc of Detection Performance by Analogue and Digital Plain Film Systems in Chest Radiography"],"prefix":"10.1177","volume":"37","author":[{"given":"R.-D.","family":"M\u00fcller","sequence":"first","affiliation":[{"name":"Central Radiological Diagnostic Institute, Biometry and Epidemiology, University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"W\u00e4hling","sequence":"additional","affiliation":[{"name":"Central Radiological Diagnostic Institute, Biometry and Epidemiology, University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Hirche","sequence":"additional","affiliation":[{"name":"Institute of Medical Information, Biometry and Epidemiology, University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Voss","sequence":"additional","affiliation":[{"name":"Central Radiological Diagnostic Institute, Biometry and Epidemiology, University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Blendl","sequence":"additional","affiliation":[{"name":"Department of Photographic Technology, The Technical School; Essen-Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Gocke","sequence":"additional","affiliation":[{"name":"Central Radiological Diagnostic Institute, Biometry and Epidemiology, University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Gocke","sequence":"additional","affiliation":[{"name":"Central Radiological Diagnostic Institute, Biometry and Epidemiology, University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Buddenbrock","sequence":"additional","affiliation":[{"name":"Central Radiological Diagnostic Institute, Biometry and Epidemiology, University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"V.","family":"John","sequence":"additional","affiliation":[{"name":"Central Radiological Diagnostic Institute, Biometry and Epidemiology, University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Wiebringhaus","sequence":"additional","affiliation":[{"name":"Central Radiological Diagnostic Institute, Biometry and Epidemiology, University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Turowski","sequence":"additional","affiliation":[{"name":"Central Radiological Diagnostic Institute, Biometry and Epidemiology, University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[1996,5,1]]},"reference":[{"key":"bibr1-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1097\/00004424-199201000-00014"},{"key":"bibr2-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1007\/BF00175438"},{"key":"bibr3-02841851960373P282","first-page":"743","volume":"161","author":"Chotas H. G.","year":"1993","journal-title":"AMBER vs asymmetric screen-film-systems. AJR"},{"key":"bibr4-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1259\/0007-1285-66-784-332"},{"key":"bibr5-02841851960373P282","doi-asserted-by":"crossref","unstructured":"Dammann F., Sokiranski C., Sch\u00e4fer H.J., Brambs H.J., Claussen C. D.: Wertigkeit des Amber-Systems bei interstitiellen Lungenver\u00e4nderungen. R\u00f6fo 163 (2) (1995), 99.","DOI":"10.1055\/s-2007-1015954"},{"key":"bibr6-02841851960373P282","unstructured":"DIN 6867, part 2: Bildregistrierendes System bestehend aus R\u00f6ntgenfilm, Verst\u00e4rkungsfolien und Kassette zur Verwendung in der medizinischen R\u00f6ntgendiagnostik \u2014 Bestimmung der Modulations\u00fcbertragungsfunktion, p. 2. Normenausschluss Radiologie (NAR), Beuth Verlag, Berlin 1992."},{"key":"bibr7-02841851960373P282","doi-asserted-by":"crossref","unstructured":"D\u00f6lken W., Chowanetz W., Horwitz A. E., Krahe T., Landwehr P., Lackner K.: Interstitielle Lungenerkrankungen. Eine Vergleichsstudie zwischen einer Film-Folien-Kombination und der digitalen Speicherfolientechnik. R\u00f6fo 156 (1992), 61.","DOI":"10.1055\/s-2008-1032837"},{"key":"bibr8-02841851960373P282","doi-asserted-by":"crossref","unstructured":"Ewen K., Steiner H., Jungblut R., G\u00fcnther G., Schoppe W.: Die Bestimmung der Organdosen bei R\u00f6ntgenaufnahmen und computertomographischen Untersuchungen sowie die Berechnung der somatisch signifikanten Dosisindizes. R\u00f6fo 133 (1980), 425.","DOI":"10.1055\/s-2008-1056757"},{"key":"bibr9-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.188.2.8327711"},{"key":"bibr10-02841851960373P282","first-page":"1","volume":"42","author":"Greene R.","year":"1989","journal-title":"Radiol. Phys. Pulm. Radiol."},{"key":"bibr11-02841851960373P282","doi-asserted-by":"crossref","unstructured":"H\u00e4ussler M. D., Lenzen H., Reckels C., Peters P. E.: Wertigkeit des asymmetrischen Film-Folien-Systems In-Sight HC in der Thoraxdiagnostik. R\u00f6fo 160 (1994), 266.","DOI":"10.1055\/s-2008-1032418"},{"key":"bibr12-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.146.3.6828707"},{"key":"bibr13-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1177\/028418519103200106"},{"key":"bibr14-02841851960373P282","first-page":"14","volume":"3","author":"Lehmann K. J.","year":"1993","journal-title":"Akt. Radiol."},{"key":"bibr15-02841851960373P282","first-page":"1259","volume":"86","author":"Leitlinien der Bundes\u00e4rztekammer zur Qualit\u00e4tssicherung in der R\u00f6ntgendiagnostik vom 09.","year":"1989","journal-title":"Dtsch. \u00c4rzteblatt"},{"key":"bibr16-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.195.1.7892482"},{"key":"bibr17-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1118\/1.595775"},{"key":"bibr18-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1097\/00004424-198903000-00012"},{"key":"bibr19-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1007\/978-4-431-66884-8_2"},{"key":"bibr20-02841851960373P282","doi-asserted-by":"crossref","unstructured":"M\u00fcller R.D., Hirche H., Voss M., Buddenbrock B., Bosch E.: ROC-Analyse zur Bildnachverarbeitung digitaler Lumineszenzradiogramme in der Thoraxdiagnostik. R\u00f6fo 162 (1995), 163.","DOI":"10.1055\/s-2007-1015854"},{"key":"bibr21-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1007\/BF00182488"},{"key":"bibr22-02841851960373P282","doi-asserted-by":"crossref","unstructured":"Neufang K. F. R., Krug B., Lorenz R., Steinbrich W.: Kann die digitale Lumineszenzradiographie (DLR) in der Thoraxdiagnostik die konventionelle R\u00f6ntgenaufnahmetechnik ersetzen? R\u00f6fo 152 (1990), 501.","DOI":"10.1055\/s-2008-1046912"},{"key":"bibr23-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.186.2.8421740"},{"key":"bibr24-02841851960373P282","first-page":"7","volume":"39","author":"Oestmann J. W.","year":"1986","journal-title":"R\u00f6ntgenbl\u00e4tter"},{"key":"bibr25-02841851960373P282","doi-asserted-by":"crossref","unstructured":"Oestmann J. W., Hendrickx P. H., Rieder P., Geerlings H.: Eignung und Vergleich von Ausgleichsfiltern f\u00fcr die Thoraxdiagnostik. R\u00f6fo 144 (1986), 395.","DOI":"10.1055\/s-2008-1048811"},{"key":"bibr26-02841851960373P282","doi-asserted-by":"crossref","unstructured":"Oestmann J. W., Galanski M.: ROC. Methodik zum Vergleich der diagnostischen Leistung bildgebender Verfahren. R\u00f6fo 151 (1989), 89.","DOI":"10.1055\/s-2008-1047135"},{"key":"bibr27-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1097\/00004424-198909000-00001"},{"key":"bibr28-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-662-05747-6_10"},{"key":"bibr29-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.178.3.1994410"},{"key":"bibr30-02841851960373P282","first-page":"354","volume":"169","author":"Schwermer B.","year":"1988","journal-title":"Radiology"},{"key":"bibr31-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.169.1.3420280"},{"key":"bibr32-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.166.2.3336719"},{"key":"bibr33-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.160.3.8430540"},{"key":"bibr34-02841851960373P282","first-page":"126","volume":"38","author":"Tuengerthal S.","year":"1985","journal-title":"R\u00f6ntgenbl\u00e4tter"},{"key":"bibr35-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.169.1.3420279"},{"key":"bibr36-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.137.4.695"},{"key":"bibr37-02841851960373P282","first-page":"292","volume":"42","author":"Witte G.","year":"1989","journal-title":"Digitale Radiographie. R\u00f6ntgenbl\u00e4tter"},{"key":"bibr38-02841851960373P282","doi-asserted-by":"publisher","DOI":"10.1259\/0007-1285-61-730-943"}],"container-title":["Acta Radiologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/02841851960373P282","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/02841851960373P282","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T13:36:58Z","timestamp":1777383418000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/02841851960373P282"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1996,5]]},"references-count":38,"journal-issue":{"issue":"3P2","published-print":{"date-parts":[[1996,5]]}},"alternative-id":["10.1177\/02841851960373P282"],"URL":"https:\/\/doi.org\/10.1177\/02841851960373p282","relation":{},"ISSN":["0284-1851","1600-0455"],"issn-type":[{"value":"0284-1851","type":"print"},{"value":"1600-0455","type":"electronic"}],"subject":[],"published":{"date-parts":[[1996,5]]}}}