{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T12:44:48Z","timestamp":1777725888128,"version":"3.51.4"},"reference-count":25,"publisher":"SAGE Publications","issue":"12","license":[{"start":{"date-parts":[[2020,12,1]],"date-time":"2020-12-01T00:00:00Z","timestamp":1606780800000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2020,12,1]],"date-time":"2020-12-01T00:00:00Z","timestamp":1606780800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/501100002858","name":"China Postdoctoral Science Foundation","doi-asserted-by":"publisher","award":["136132"],"award-info":[{"award-number":["136132"]}],"id":[{"id":"10.13039\/501100002858","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81974576"],"award-info":[{"award-number":["81974576"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Int Med Res"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:p>\n                    We herein report a case involving three failures of internal fixation after periprosthetic femoral fracture (Vancouver type B1). The patient had low bone mass (T-score of \u22121.7) and was overweight (body mass index of 28.7 kg\/m\n                    <jats:sup>2<\/jats:sup>\n                    ) but had no sign of femoral stem loosening. The first open reduction with internal fixation was performed according to the recommended treatment. Unexpectedly, three treatment failures subsequently occurred, after which the patient finally attained endurable walking activity. A literature review indicated that the intrinsic biomechanical problems of Vancouver B1 fractures have not been thoroughly addressed. Choosing the correct surgical strategy for Vancouver B1 fractures is essential to avoid complications and ensure healing. A sufficient locking plate and cable system should be used after the first failure if revision was not performed the first time.\n                  <\/jats:p>","DOI":"10.1177\/0300060520958972","type":"journal-article","created":{"date-parts":[[2020,12,10]],"date-time":"2020-12-10T13:20:41Z","timestamp":1607606441000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Multiple failures of internal fixation for treatment of periprosthetic femoral refracture: a case report and literature review"],"prefix":"10.1177","volume":"48","author":[{"given":"Jing","family":"Shen","sequence":"first","affiliation":[{"name":"Orthopedics Department, The First Affiliated Hospital of Zhejiang Chinese Medical University, HangZhou, ZheJiang, P.R. China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yang","family":"Zhang","sequence":"additional","affiliation":[{"name":"Traditional Chinese Medical hospital of Zhuji, Zhejiang province, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guisong","family":"Yu","sequence":"additional","affiliation":[{"name":"Lishui people's hospital, Lishui, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6920-0647","authenticated-orcid":false,"given":"Weifeng","family":"Ji","sequence":"additional","affiliation":[{"name":"Orthopedics Department, The First Affiliated Hospital of Zhejiang Chinese Medical University, HangZhou, ZheJiang, P.R. China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2020,12,8]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200704000-00012"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2005.02.001"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-018-3930-y"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.98B4.37201"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-008-0289-1"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.00331"},{"key":"e_1_3_3_8_2","first-page":"68","article-title":"Total hip arthroplasty periprosthetic femoral fractures: a review of classification and current treatment","volume":"71","author":"Schwarzkopf R","year":"2013","unstructured":"Schwarzkopf R, Oni JK, Marwin SE. Total hip arthroplasty periprosthetic femoral fractures: a review of classification and current treatment. Bull Hosp Jt Dis (2013) 2013; 71: 68\u201378.","journal-title":"Bull Hosp Jt Dis (2013)"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20161116-06"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.93B1.25087"},{"key":"e_1_3_3_11_2","first-page":"243","article-title":"Periprosthetic fracture of the femur after total hip arthroplasty: treatment and results to date","volume":"47","author":"Lewallen DG","year":"1998","unstructured":"Lewallen DG, Berry DJ. Periprosthetic fracture of the femur after total hip arthroplasty: treatment and results to date. Instr Course Lect 1998; 47: 243\u2013249.","journal-title":"Instr Course Lect"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2018.09.045"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-015-2979-0"},{"key":"e_1_3_3_14_2","first-page":"2240","article-title":"Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant","volume":"87","author":"Ricci WM","year":"2005","unstructured":"Ricci WM, Bolhofner BR, Loftus T, et\u00a0al. Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. J Bone Joint Surg Am 2005; 87: 2240\u20132245.","journal-title":"J Bone Joint Surg Am"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2011.01.008"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-011-1272-y"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200403000-00012"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.88B1.17029"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-015-2967-4"},{"key":"e_1_3_3_20_2","first-page":"234","article-title":"Periprosthetic fractures around the femoral stem: overcoming challenges and avoiding pitfalls","volume":"3","author":"Fleischman AN","year":"2015","unstructured":"Fleischman AN, Chen AF. Periprosthetic fractures around the femoral stem: overcoming challenges and avoiding pitfalls. Ann Transl Med 2015; 3: 234.","journal-title":"Ann Transl Med"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.99B4.BJJ-2016-1311.R1"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.99B4.BJJ-2016-1201.R1"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.11138\/ccmbm\/2017.14.1.136"},{"key":"e_1_3_3_24_2","first-page":"62","article-title":"Atypical femoral fracture on a deformed bone, treated with a multimodal approach. A case report","volume":"16","author":"Cesari M","year":"2019","unstructured":"Cesari M, Mondanelli N, Gonnelli S, , . et\u00a0al Atypical femoral fracture on a deformed bone, treated with a multimodal approach. A case report. Clin Cases Miner Bone Metab 2019; 16: 62\u201365.","journal-title":"Clin Cases Miner Bone Metab"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1177\/2151459319876859"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2013.08.010"}],"container-title":["Journal of International Medical Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0300060520958972","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0300060520958972","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0300060520958972","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T10:43:56Z","timestamp":1777459436000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0300060520958972"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12]]},"references-count":25,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["10.1177\/0300060520958972"],"URL":"https:\/\/doi.org\/10.1177\/0300060520958972","relation":{},"ISSN":["0300-0605","1473-2300"],"issn-type":[{"value":"0300-0605","type":"print"},{"value":"1473-2300","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12]]},"article-number":"0300060520958972"}}