{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T13:21:06Z","timestamp":1777728066792,"version":"3.51.4"},"reference-count":27,"publisher":"SAGE Publications","issue":"10","license":[{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/501100017577","name":"Basic Public Welfare Research Program of Zhejiang Province","doi-asserted-by":"publisher","award":["GF21H120010"],"award-info":[{"award-number":["GF21H120010"]}],"id":[{"id":"10.13039\/501100017577","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Int Med Res"],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This prospective study aimed to evaluate anterior segment parameters after neodymium-doped yttrium-aluminum-garnet laser posterior capsulotomy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The central corneal thickness, anterior chamber depth, lens vault, and pupil diameter measurements were taken using the novel anterior segment swept-source optical coherence tomography system. The tilt of the intraocular lens was measured with the Optical Path Difference Scan III. The examinations were performed preoperatively and repeated at postoperative 30\u2009min, 1 week, and 1 month. The patients were divided into two groups according to the type of lens used: C-loop\u2013type (n\u2009=\u200918) and plate-type (n\u2009=\u200918) intraocular lens.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The mean central corneal thickness (\n                      <jats:italic toggle=\"yes\">p\u2009<\/jats:italic>\n                      &lt;\n                      <jats:italic toggle=\"yes\">\u2009<\/jats:italic>\n                      0.001), anterior chamber depth (\n                      <jats:italic toggle=\"yes\">p\u2009<\/jats:italic>\n                      &lt;\n                      <jats:italic toggle=\"yes\">\u2009<\/jats:italic>\n                      0.001), and lens vault (\n                      <jats:italic toggle=\"yes\">p\u2009<\/jats:italic>\n                      =\n                      <jats:italic toggle=\"yes\">\u2009<\/jats:italic>\n                      0.005) were increased significantly at 30\u2009min and then returned to baseline values at 1 week and 1 month after the capsulotomy. Furthermore, the mean increase in the degree of anterior chamber depth and lens vault in the plate-type intraocular lens group was more than that in the C-loop\u2013type intraocular lens group at postoperative 30\u2009min; however, these increases were not significantly different (\n                      <jats:italic toggle=\"yes\">p\u2009<\/jats:italic>\n                      &gt;\n                      <jats:italic toggle=\"yes\">\u2009<\/jats:italic>\n                      0.05). The mean tilt of the intraocular lens values did not change significantly after capsulotomy in both groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Neodymium-doped yttrium-aluminum-garnet capsulotomy causes a temporary increase in the central corneal thickness, anterior chamber depth, and lens vault; however, it does not significantly alter the tilt of the intraocular lens.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/03000605251389806","type":"journal-article","created":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T03:51:18Z","timestamp":1761882678000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Changes in anterior segment parameters after neodymium-doped yttrium-aluminum-garnet laser capsulotomy: A prospective study"],"prefix":"10.1177","volume":"53","author":[{"given":"Haiyang","family":"Yu","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Key Laboratory for Corneal Diseases Research of Zhejiang Province, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yixu","family":"Mao","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Key Laboratory for Corneal Diseases Research of Zhejiang Province, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-1449-120X","authenticated-orcid":false,"given":"Bei","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Key Laboratory for Corneal Diseases Research of Zhejiang Province, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2025,10,30]]},"reference":[{"key":"e_1_3_10_2_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-023-03064-3"},{"key":"e_1_3_10_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-020-01397-2"},{"key":"e_1_3_10_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10103-023-03958-0"},{"key":"e_1_3_10_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.pdpdt.2023.103653"},{"key":"e_1_3_10_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000755"},{"key":"e_1_3_10_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001306"},{"key":"e_1_3_10_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/lsm.22273"},{"key":"e_1_3_10_9_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S80220"},{"key":"e_1_3_10_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0000000000000185"},{"key":"e_1_3_10_11_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S203677"},{"key":"e_1_3_10_12_2","doi-asserted-by":"publisher","DOI":"10.12669\/pjms.342.12705"},{"key":"e_1_3_10_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/cxo.12205"},{"key":"e_1_3_10_14_2","doi-asserted-by":"publisher","DOI":"10.5507\/bp.2021.014"},{"key":"e_1_3_10_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(07)61602-X"},{"key":"e_1_3_10_16_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-018-0068-5"},{"key":"e_1_3_10_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2017.03.005"},{"key":"e_1_3_10_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190708-02"},{"key":"e_1_3_10_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.10.045"},{"key":"e_1_3_10_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.01.034"},{"key":"e_1_3_10_21_2","first-page":"259","article-title":"[Central corneal thickness measurement by optical coherence tomography after Nd: YAG capsulotomy in patients with posterior capsule opacity]","volume":"110","author":"Wr\u00f3blewska-Czajka E","year":"2008","unstructured":"Wr\u00f3blewska-Czajka E, Wyl\u0119ga\u0142a E. [Central corneal thickness measurement by optical coherence tomography after Nd: YAG capsulotomy in patients with posterior capsule opacity]. Klin Oczna 2008; 110: 259\u2013264.","journal-title":"Klin Oczna"},{"key":"e_1_3_10_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01204329"},{"key":"e_1_3_10_23_2","first-page":"431","article-title":"[Observation of the cornea with confocal microscopy after Nd: YAG laser capsulotomy]","volume":"102","author":"Filipecka I","year":"2000","unstructured":"Filipecka I, Gierek-Ciaciura S, Formi\u0144ska-Kapu\u015bcik M, et\u00a0al. [Observation of the cornea with confocal microscopy after Nd: YAG laser capsulotomy]. Klin Oczna 2000; 102: 431\u2013433.","journal-title":"Klin Oczna"},{"key":"e_1_3_10_24_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S349649"},{"key":"e_1_3_10_25_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S156703"},{"key":"e_1_3_10_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10103-025-04555-z"},{"key":"e_1_3_10_27_2","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10194384"},{"key":"e_1_3_10_28_2","doi-asserted-by":"publisher","DOI":"10.1111\/cxo.12888"}],"container-title":["Journal of International Medical Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/03000605251389806","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/03000605251389806","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/03000605251389806","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T10:51:11Z","timestamp":1777459871000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/03000605251389806"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":27,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1177\/03000605251389806"],"URL":"https:\/\/doi.org\/10.1177\/03000605251389806","relation":{},"ISSN":["0300-0605","1473-2300"],"issn-type":[{"value":"0300-0605","type":"print"},{"value":"1473-2300","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10]]},"article-number":"03000605251389806"}}