{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,19]],"date-time":"2026-07-19T04:03:19Z","timestamp":1784433799110,"version":"3.55.0"},"reference-count":26,"publisher":"SAGE Publications","issue":"7","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"name":"Science and Technology Fund Project of Guizhou Provincial Health Commission","award":["gzwkj2026-218"],"award-info":[{"award-number":["gzwkj2026-218"]}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Int Med Res"],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To investigate the clinical value of radial endobronchial ultrasound (rEBUS) combined with rapid on-site evaluation (ROSE) under hand-drawn bronchial navigation (HBN) planning for the diagnosis of peripheral pulmonary lesions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of 186 patients were enrolled in this retrospective case\u2013control study and classified into three groups according to the intervention method: rEBUS group (n\u2009=\u200974), HBN-rEBUS group (n\u2009=\u200957), and HBN-rEBUS-ROSE group (n\u2009=\u200954). The final diagnostic yield, lesion detection rate, time to lesion localization, number of biopsies performed, and incidence of complications were compared across the three groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The lesion detection rate was higher in the HBN-rEBUS group than in the rEBUS group, and the HBN-rEBUS group demonstrated fewer ultrasound probe passes and a shorter time to lesion localization (p\u2009&lt;\u20090.001). The HBN-rEBUS-ROSE group required fewer biopsies and had a lower incidence of bleeding than the HBN-rEBUS group (p\u2009&lt;\u20090.001). The HBN-rEBUS-ROSE group also achieved a higher diagnostic yield than both the rEBUS and HBN-rEBUS groups (p\u2009&lt;\u20090.05).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>HBN-rEBUS facilitates faster and more precise localization of peripheral pulmonary lesions, shortens procedural duration, and, when combined with ROSE, reduces bleeding and improves the diagnostic yield of peripheral pulmonary lesions.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/03000605261468572","type":"journal-article","created":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T04:32:23Z","timestamp":1784262743000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Application of hand-drawn bronchial navigation and rapid on-site evaluation combined with endobronchial ultrasound for the diagnosis of peripheral lung lesions"],"prefix":"10.1177","volume":"54","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-0871-6193","authenticated-orcid":false,"given":"Maofei","family":"Fan","sequence":"first","affiliation":[{"name":"The Affiliated Anshun Central Hospital of Guizhou Medical University (non-directly affiliated)"},{"name":"Department of Pulmonary and Critical Care Medicine, The Affiliated Hospital of Guizhou Medical University, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renyuan","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Pulmonary and Critical Care Medicine, People's Hospital of Xixiu District Anshun City, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qian","family":"Zhu","sequence":"additional","affiliation":[{"name":"Department of Pulmonary and Critical Care Medicine, The Affiliated Hospital of Guizhou Medical University, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Menglin","family":"Zhang","sequence":"additional","affiliation":[{"name":"The Affiliated Anshun Central Hospital of Guizhou Medical University (non-directly affiliated)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-1359-6150","authenticated-orcid":false,"given":"Qingqing","family":"Zhou","sequence":"additional","affiliation":[{"name":"The Affiliated Anshun Central Hospital of Guizhou Medical University (non-directly affiliated)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiwei","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Pulmonary and Critical Care Medicine, The Affiliated Hospital of Guizhou Medical University, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,7,16]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.3322\/caac.21834"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2021.0377"},{"key":"e_1_3_3_4_2","first-page":"119","article-title":"Diagnostic value and safety of electromagnetic navigation bronchoscopy in peripheral pulmonary lesions: a meta-analysis","volume":"26","author":"Sun X","year":"2023","unstructured":"Sun X, Su Y, Li S, et al. Diagnostic value and safety of electromagnetic navigation bronchoscopy in peripheral pulmonary lesions: a meta-analysis. Zhongguo Fei Ai Za Zhi 2023; 26: 119\u2013134. Chinese.","journal-title":"Zhongguo Fei Ai Za Zhi"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/0300060521999535"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.lungcan.2023.107196"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12931-022-02160-0"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2020.05.534"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/crj.13768"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2019.10.042"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.pulmoe.2020.06.007"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12890-024-03208-1"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.39335.541782.AD"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/1759-7714.12279"},{"key":"e_1_3_3_15_2","first-page":"573","article-title":"Guideline for diagnostic flexible bronchoscopy in adults (2019)","volume":"42","author":"Interventional pulmonology group of the Chinese Thoracic Society, Chinese Medical Association","year":"2019","unstructured":"Interventional pulmonology group of the Chinese Thoracic Society, Chinese Medical Association. Guideline for diagnostic flexible bronchoscopy in adults (2019). Zhonghua Jie He Hu Xi Za Zhi 2019; 42: 573\u2013590. Chinese.","journal-title":"Zhonghua Jie He Hu Xi Za Zhi"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.21037\/jtd-23-979"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1183\/16000617.0046-2024"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.201907-1292SO"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2019.10.013"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1093\/jjco\/hyt224"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1183\/13993003.01678-2021"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.3390\/cancers13225751"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.resinv.2020.03.004"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1513\/AnnalsATS.202109-1071OC"},{"key":"e_1_3_3_25_2","first-page":"1310","article-title":"Diagnostic value of virtual navigation system combined with radial ultrasonic bronchoscopy in peripheral pulmonary lesions","volume":"28","author":"Zhou MT","year":"2023","unstructured":"Zhou MT, Shen Y, Zhang XM. Diagnostic value of virtual navigation system combined with radial ultrasonic bronchoscopy in peripheral pulmonary lesions. J Clin Pulmonol 2023; 28: 1310\u20131316. Chinese.","journal-title":"J Clin Pulmonol"},{"key":"e_1_3_3_26_2","first-page":"72","article-title":"Improvements in diagnosing peripheral lung lesions with a hand-drawn bronchial map by endobronchial ultrasonography","volume":"31","author":"Wu SC","year":"2025","unstructured":"Wu SC, Ni FH, Duan T, et al. Improvements in diagnosing peripheral lung lesions with a hand-drawn bronchial map by endobronchial ultrasonography. China J Endosc 2025; 31: 72\u201379. Chinese.","journal-title":"China J Endosc"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.3390\/healthcare12131260"}],"container-title":["Journal of International Medical Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/03000605261468572","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/03000605261468572","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/03000605261468572","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,19]],"date-time":"2026-07-19T03:47:12Z","timestamp":1784432832000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/03000605261468572"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":26,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["10.1177\/03000605261468572"],"URL":"https:\/\/doi.org\/10.1177\/03000605261468572","relation":{},"ISSN":["0300-0605","1473-2300"],"issn-type":[{"value":"0300-0605","type":"print"},{"value":"1473-2300","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]},"article-number":"03000605261468572"}}