{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,17]],"date-time":"2026-01-17T02:47:01Z","timestamp":1768618021342,"version":"3.49.0"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2019,4,1]],"date-time":"2019-04-01T00:00:00Z","timestamp":1554076800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2019,4]]},"DOI":"10.1177\/0309364618806038","type":"journal-article","created":{"date-parts":[[2018,10,22]],"date-time":"2018-10-22T07:32:12Z","timestamp":1540193532000},"page":"213-220","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":15,"title":["Reliability and validity of the iSense optical scanner for measuring volume of transtibial residual limb models"],"prefix":"10.1097","volume":"43","author":[{"given":"Lucy","family":"Armitage","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Li Khim","family":"Kwah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lauren","family":"Kark","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R2-12-20210303","first-page":"77","article-title":"Validity and reliability of girth measurement (circumference measurement) for calculating residual limb volume in below-knee amputees","volume":"51","author":"Boonhong","year":"2007","journal-title":"Chula Med J"},{"key":"R3-12-20210303","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1097\/PHM.0b013e3181d3ea94","article-title":"Variation in measurements of transtibial stump model volume: a comparison of five methods","volume":"89","author":"Bolt","year":"2010","journal-title":"Am J Phys Med Rehabil"},{"key":"R4-12-20210303","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1682\/JRRD.2006.08.0088","article-title":"Consistency, precision, and accuracy of optical and electromagnetic shape-capturing systems for digital measurement of residual-limb anthropometrics of persons with transtibial amputation","volume":"44","author":"Geil","year":"2007","journal-title":"J Rehabil Res Dev"},{"key":"R5-12-20210303","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1682\/JRRD.2014.10.0272","article-title":"Registering methodology for imaging and analysis of residual-limb shape after transtibial amputation","volume":"53","author":"Dickinson","year":"2016","journal-title":"J Rehabil Res Dev"},{"key":"R6-12-20210303","first-page":"27","article-title":"Accuracy and precision of volumetric determinations using two commercial CAD systems for prosthetics: a technical note","volume":"35","author":"Johansson","year":"1998","journal-title":"J Rehabil Res Dev"},{"key":"R7-12-20210303","first-page":"141","article-title":"Volumetric determinations with CAD\/CAM in prosthetics and orthotics: errors of measurement","volume":"32","author":"Lilja","year":"1995","journal-title":"J Rehabil Res Dev"},{"key":"R8-12-20210303","doi-asserted-by":"crossref","first-page":"20","DOI":"10.3109\/03093640902929285","article-title":"Inter- and intra-observer reproducibility and validity of an indirect volume measurement in transtibial amputees","volume":"34","author":"Van Stuivenberg-Vrielink","year":"2010","journal-title":"Prosthet Orthot Int"},{"key":"R9-12-20210303","doi-asserted-by":"crossref","first-page":"e0184498","DOI":"10.1371\/journal.pone.0184498","article-title":"Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees\u2019 residual limb models","volume":"12","author":"Seminati","year":"2017","journal-title":"PLoS ONE"},{"key":"R10-12-20210303","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.jclinepi.2010.03.002","article-title":"Guidelines for reporting reliability and agreement studies (GRRAS) were proposed","volume":"64","author":"Kottner","year":"2011","journal-title":"J Clin Epidemiol"},{"key":"R11-12-20210303","doi-asserted-by":"crossref","first-page":"1331","DOI":"10.1002\/sim.1108","article-title":"Sample size requirements for estimating intraclass correlations with desired precision","volume":"21","author":"Bonett","year":"2002","journal-title":"Stat Med"},{"key":"R12-12-20210303","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1016\/j.apmr.2011.01.007","article-title":"Variation in results of volume measurements of stumps of lower-limb amputees: a comparison of 4 methods","volume":"92","author":"De Boer-Wilzing","year":"2011","journal-title":"Arch Phys Med Rehabil"},{"key":"R13-12-20210303","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1186\/s12966-016-0351-4","article-title":"Should we reframe how we think about physical activity and sedentary behaviour measurement? Validity and reliability reconsidered","volume":"13","author":"Kelly","year":"2016","journal-title":"Int J Behav Nutr Phys Act"},{"key":"R14-12-20210303","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"},{"key":"R15-12-20210303","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1093\/bja\/aem214","article-title":"Using the Bland-Altman method to measure agreement with repeated measures","volume":"99","author":"Myles","year":"2007","journal-title":"Br J Anaesth"},{"key":"R16-12-20210303","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/S0003-9993(96)90037-4","article-title":"Precision of surface measurements for below-knee residua","volume":"77","author":"Commean","year":"1996","journal-title":"Arch Phys Med Rehabil"},{"key":"R18-12-20210303","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1097\/00008526-199700940-00006","article-title":"Performance of a continuously sampling hand-held digitizer for residual-limb shape measurement","volume":"9","author":"Vannah","year":"1997","journal-title":"J Prosthetics Orthot"},{"key":"R19-12-20210303","first-page":"311","article-title":"Clinical analysis of a CAD\/CAM system for custom seating: a comparison with hand-sculpting methods","volume":"33","author":"Lemaire","year":"1996","journal-title":"J Rehabil Res Dev"},{"key":"R20-12-20210303","doi-asserted-by":"crossref","first-page":"115","DOI":"10.3109\/03093649809164472","article-title":"Morphological changes during early trans-tibial prosthetic fitting","volume":"22","author":"Lilja","year":"1998","journal-title":"Prosthet Orthot Int"},{"key":"R21-12-20210303","doi-asserted-by":"crossref","first-page":"97","DOI":"10.3109\/03093649509080351","article-title":"Validation of spiral CT and optical surface scanning for lower limb stump volumetry","volume":"19","author":"Smith","year":"1995","journal-title":"Prosthet Orthot Int"},{"key":"R22-12-20210303","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1080\/03093640802015920","article-title":"Evaluation of the effect of shape on a contemporary CAD system","volume":"32","author":"McGarry","year":"2008","journal-title":"Prosthet Orthot Int"},{"key":"R23-12-20210303","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1186\/s40064-015-1468-7","article-title":"Limb volume measurements: comparison of accuracy and decisive parameters of the most used present methods","volume":"4","author":"Chromy","year":"2015","journal-title":"Springerplus"},{"key":"R24-12-20210303","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1016\/S0003-9993(98)90355-0","article-title":"Below-knee residual limb shape change measurement and visualization","volume":"79","author":"Commean","year":"1998","journal-title":"Arch Phys Med Rehabil"},{"key":"R25-12-20210303","first-page":"487","article-title":"State-of-the-art methods for geometric and biomechanical assessments of residual limbs: a review","volume":"38","author":"Zheng","year":"2001","journal-title":"J Rehabil Res Dev"}],"container-title":["Prosthetics &amp; Orthotics International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0309364618806038","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0309364618806038","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/00006479-201943020-00012","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,3]],"date-time":"2021-03-03T17:56:36Z","timestamp":1614794196000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00006479-201943020-00012"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4]]},"references-count":23,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1177\/0309364618806038","relation":{},"ISSN":["0309-3646"],"issn-type":[{"value":"0309-3646","type":"print"}],"subject":[],"published":{"date-parts":[[2019,4]]}}}