{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T12:00:08Z","timestamp":1777377608983,"version":"3.51.4"},"reference-count":6,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2010,1,1]],"date-time":"2010-01-01T00:00:00Z","timestamp":1262304000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesth Intensive Care"],"published-print":{"date-parts":[[2010,1]]},"abstract":"<jats:p>\n                    The effects of blood solubility, cardiac output and ventilation on the rise of the alveolar towards the inspired concentration, the FA\/F\n                    <jats:sub>I<\/jats:sub>\n                    curve, of an inhaled anaesthetic are often thought to reflect how these factors affect wash-in of the central nervous system compartment and, therefore, speed of induction because If is the partial pressure ultimately attained in the central nervous system (F\n                    <jats:sub>VRG<\/jats:sub>\n                    ). These classical F\n                    <jats:sub>A<\/jats:sub>\n                    \/F\n                    <jats:sub>I<\/jats:sub>\n                    curves assumed a constant F\n                    <jats:sub>I<\/jats:sub>\n                    . We used GasMan\u00ae to examine whether changes in solubility, cardiac output and ventilation affect the relationship between the F\n                    <jats:sub>A<\/jats:sub>\n                    \/F\n                    <jats:sub>I<\/jats:sub>\n                    curve and F\n                    <jats:sub>VRG<\/jats:sub>\n                    differently while either F\n                    <jats:sub>I<\/jats:sub>\n                    or F\n                    <jats:sub>A<\/jats:sub>\n                    are kept constant.\n                  <\/jats:p>\n                  <jats:p>\n                    Using GasMan\u00ae, we studied the effects of solubility (desflurane vs isoflurane), cardiac output (5 vs 10 l.min\n                    <jats:sub>-1<\/jats:sub>\n                    ) and minute ventilation (4 vs 8 l.min\n                    <jats:sub>-1<\/jats:sub>\n                    ) on F\n                    <jats:sub>A<\/jats:sub>\n                    , F\n                    <jats:sub>I<\/jats:sub>\n                    F\n                    <jats:sub>A<\/jats:sub>\n                    \/F\n                    <jats:sub>I<\/jats:sub>\n                    . and F\n                    <jats:sub>VRG<\/jats:sub>\n                    with either F\n                    <jats:sub>I<\/jats:sub>\n                    kept constant or F\n                    <jats:sub>A<\/jats:sub>\n                    kept constant (at 1 minimum alveolar concentration). High fresh gas flows were used to avoid rebreathing, so that the delivered concentration matched F\n                    <jats:sub>I<\/jats:sub>\n                    .\n                  <\/jats:p>\n                  <jats:p>\n                    Despite similar effects on the F\n                    <jats:sub>A<\/jats:sub>\n                    \/F\n                    <jats:sub>I<\/jats:sub>\n                    curve, the effects on F\n                    <jats:sub>VRG<\/jats:sub>\n                    differed. With constant F\n                    <jats:sub>I<\/jats:sub>\n                    , lower solubility or higher ventilation results in a higher F\n                    <jats:sub>VRG<\/jats:sub>\n                    and a higher cardiac output results in a lower F\n                    <jats:sub>VRG<\/jats:sub>\n                    With constant F\n                    <jats:sub>A<\/jats:sub>\n                    , solubility has only a minimal effect on F\n                    <jats:sub>VRG<\/jats:sub>\n                    ; an increase in cardiac output hastens the rise of F\n                    <jats:sub>VRG<\/jats:sub>\n                    to the same plateau value; and a change in ventilation has minimal effect on F\n                    <jats:sub>VRG<\/jats:sub>\n                    .\n                  <\/jats:p>\n                  <jats:p>\n                    Despite similar effects on the F\n                    <jats:sub>A<\/jats:sub>\n                    \/F\n                    <jats:sub>I<\/jats:sub>\n                    curve, the effects of solubility, cardiac output and ventilation on the F\n                    <jats:sub>VRG<\/jats:sub>\n                    are different when either F\n                    <jats:sub>I<\/jats:sub>\n                    or F\n                    <jats:sub>A<\/jats:sub>\n                    are kept constant. With the F\n                    <jats:sub>I<\/jats:sub>\n                    kept constant, induction of anaesthesia is slower with a higher cardiac output, but with F\n                    <jats:sub>A<\/jats:sub>\n                    kept constant, induction of anaesthesia is faster with a higher cardiac output. The introduction of an end-expired closed-loop feedback administration of inhaled anaesthetics makes this distinction clinically relevant.\n                  <\/jats:p>","DOI":"10.1177\/0310057x1003800114","type":"journal-article","created":{"date-parts":[[2019,1,22]],"date-time":"2019-01-22T23:32:01Z","timestamp":1548199921000},"page":"76-81","source":"Crossref","is-referenced-by-count":12,"title":["Effect of the Mode of Administration of Inhaled Anaesthetics on the Interpretation of the F\n                    <sub>A<\/sub>\n                    \/F\n                    <sub>I<\/sub>\n                    Curve \u2013 a GasMan\u00ae Simulation"],"prefix":"10.1177","volume":"38","author":[{"given":"T.","family":"Van Zundert","sequence":"first","affiliation":[{"name":"Department of Anaesthesiology, Intensive Care and Pain Therapy; Onze Lieve Vrouw Hospital, Aalst, Belgium and University of Maastricht, Maastricht, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Hendrickx","sequence":"additional","affiliation":[{"name":"Consultant Anaesthesiologist, Department of Anaesthesiology, Intensive Care and Pain Therapy, Onze Lieve Vrouw Hospital and Consulting Assistant Professor, Stanford University, Stanford, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Brebels","sequence":"additional","affiliation":[{"name":"Resident Anaesthesiologist, Department of Anaesthesiology, Intensive Care and Pain Therapy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"De Cooman","sequence":"additional","affiliation":[{"name":"Consultant Anaesthesiologist, Department of Anaesthesiology, Institut Jules Bordet, Universit\u00e9 Libre de Bruxelles, Brussels, Belgium."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Gatt","sequence":"additional","affiliation":[{"name":"Professor and Consultant Anaesthesiologist, Department of Anaesthesiology and Intensive Care, University of New South Wales, Prince of Wales and Sydney Children's Hospital, Sydney, New South Wales, Australia."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"De Wolf","sequence":"additional","affiliation":[{"name":"Professor, Department of Anesthesiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2010,1,1]]},"reference":[{"key":"bibr1-0310057X1003800114","volume-title":"Anesthetic uptake and action.","author":"Eger EI","year":"1974"},{"key":"bibr2-0310057X1003800114","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-196511000-00010"},{"key":"bibr3-0310057X1003800114","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-197007000-00004"},{"key":"bibr4-0310057X1003800114","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aei051"},{"key":"bibr5-0310057X1003800114","doi-asserted-by":"publisher","DOI":"10.1007\/BF01716358"},{"key":"bibr6-0310057X1003800114","doi-asserted-by":"publisher","DOI":"10.1213\/01.ANE.0000158611.15820.3D"}],"container-title":["Anaesthesia and Intensive Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0310057X1003800114","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0310057X1003800114","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T09:08:08Z","timestamp":1777367288000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0310057X1003800114"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1]]},"references-count":6,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,1]]}},"alternative-id":["10.1177\/0310057X1003800114"],"URL":"https:\/\/doi.org\/10.1177\/0310057x1003800114","relation":{},"ISSN":["0310-057X","1448-0271"],"issn-type":[{"value":"0310-057X","type":"print"},{"value":"1448-0271","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,1]]}}}