{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T16:20:11Z","timestamp":1794932411559,"version":"4.9.1"},"reference-count":14,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2012,7,1]],"date-time":"2012-07-01T00:00:00Z","timestamp":1341100800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Anaesth Intensive Care"],"published-print":{"date-parts":[[2012,7]]},"abstract":"<jats:p>\n                    Cerebrospinal fluid (CSF) and nerve root volumes within the lumbosacral dural sac were estimated at various vertebral levels, in an attempt to determine any possible relevance to the incidence of nerve root trauma during lumbar puncture or spinal anaesthesia. Magnetic resonance images from seven patients were studied. Volumes were calculated by semi-automatic threshold segmentation combined with manual editing of each slice. The mean dural sac volume from S1 to T12 was 42.8\u00b15.8 ml and the mean CSF volume 34.3\u00b15.1 ml with the mean root volume being 10.4\u00b12.2 cm\n                    <jats:sup>3<\/jats:sup>\n                    . The mean CSF volume per vertebral segment ranged from 4.3\u00b10.7 ml at L5, to 5.8\u00b12.5 ml at L1, with high inter-individual variability. The mean root volume ranged from 0.6\u00b10.1 cm\n                    <jats:sup>3<\/jats:sup>\n                    at L5 to 2.4\u00b10.5 cm\n                    <jats:sup>3<\/jats:sup>\n                    at T12.\n                  <\/jats:p>\n                  <jats:p>The conus medullaris was located at L1 in four of the five patients scanned at upper lumbar levels, and at the lower border of L2 in the other. Vulnerability to nerve root damage was expressed as the Vulnerability Index (%), being defined as the ratio of root volume to dural sac volume (CSF volume + root volume). The value ranged between 7 and 14% at L5, increasing rostrally to 30 to 43% at T12. Caution is obviously required in high punctures to avoid contact with the conus medullaris, but the cauda equina is also vulnerable to contact with more caudal punctures and had a Vulnerability Index of about 25% at L4, that increased rostrally.<\/jats:p>","DOI":"10.1177\/0310057x1204000410","type":"journal-article","created":{"date-parts":[[2019,1,16]],"date-time":"2019-01-16T04:28:51Z","timestamp":1547612931000},"page":"643-647","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":23,"title":["Cerebrospinal Fluid Volume and Nerve Root Vulnerability during Lumbar Puncture or Spinal Anaesthesia at Different Vertebral Levels"],"prefix":"10.1177","volume":"40","author":[{"given":"A.","family":"Prats-Galino","sequence":"first","affiliation":[{"name":"Laboratory of Surgical NeuroAnatomy, Human Anatomy and Embryology Unit, Faculty of Medicine, University of Barcelona, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. A.","family":"Reina","sequence":"additional","affiliation":[{"name":"Laboratory of Surgical NeuroAnatomy, Human Anatomy and Embryology Unit, Faculty of Medicine, University of Barcelona, Barcelona, Spain"},{"name":"Department of Clinical Medical Sciences and Applied Molecular Medicine Institute, CEU San Pablo University School of Medicine and Department of Anesthesiology, Madrid-Montepr\u00edncipe University Hospital, Madrid."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Puigdell\u00edvol-S\u00e1nchez","sequence":"additional","affiliation":[{"name":"Laboratory of Surgical NeuroAnatomy, Human Anatomy and Embryology Unit, Faculty of Medicine, University of Barcelona, Barcelona, Spain"},{"name":"Laboratory of Surgical NeuroAnatomy and Ant\u00f3n Borja Primary Care Centre, Rub\u00ed."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. A.","family":"Juanes M\u00e9ndez","sequence":"additional","affiliation":[{"name":"Laboratory of Surgical NeuroAnatomy, Human Anatomy and Embryology Unit, Faculty of Medicine, University of Barcelona, Barcelona, Spain"},{"name":"Unit of Anatomy and Human Embryology, Faculty of Medicine, University of Salamanca, Salamanca."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. A.","family":"De Andr\u00e9s","sequence":"additional","affiliation":[{"name":"Laboratory of Surgical NeuroAnatomy, Human Anatomy and Embryology Unit, Faculty of Medicine, University of Barcelona, Barcelona, Spain"},{"name":"Department of Critical Care and Multidisciplinary Pain Management, General University Hospital, Valencia."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C. B.","family":"Collier","sequence":"additional","affiliation":[{"name":"Laboratory of Surgical NeuroAnatomy, Human Anatomy and Embryology Unit, Faculty of Medicine, University of Barcelona, Barcelona, Spain"},{"name":"Department of Obstetric Anaesthesia, Prince of Wales Private Hospital, Sydney, New South Wales, Australia."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2012,7,1]]},"reference":[{"key":"bibr1-0310057X1204000410","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1960.03020140019005"},{"key":"bibr2-0310057X1204000410","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199709000-00005"},{"key":"bibr3-0310057X1204000410","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1213\/00000539-199705000-00020","volume":"84","author":"Horlocker T.T.","year":"1997","journal-title":"Anesth Analg"},{"key":"bibr4-0310057X1204000410","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-196903000-00011"},{"key":"bibr5-0310057X1204000410","first-page":"29","volume":"34","author":"Pong R.P.","year":"2009","journal-title":"Reg Anesth Pain Med"},{"key":"bibr6-0310057X1204000410","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200312000-00018"},{"key":"bibr7-0310057X1204000410","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199209001-00875"},{"key":"bibr8-0310057X1204000410","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199606000-00010"},{"key":"bibr9-0310057X1204000410","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200401000-00019"},{"key":"bibr10-0310057X1204000410","doi-asserted-by":"publisher","DOI":"10.1213\/01.ane.0000240886.55044.47"},{"key":"bibr11-0310057X1204000410","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200403000-00056"},{"key":"bibr12-0310057X1204000410","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200411000-00044"},{"key":"bibr13-0310057X1204000410","doi-asserted-by":"publisher","DOI":"10.1097\/AAP.0b013e3181ac7bff"},{"key":"bibr14-0310057X1204000410","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2006.04641.x"}],"container-title":["Anaesthesia and Intensive Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0310057X1204000410","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0310057X1204000410","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T09:07:14Z","timestamp":1777367234000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0310057X1204000410"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,7]]},"references-count":14,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2012,7]]}},"alternative-id":["10.1177\/0310057X1204000410"],"URL":"https:\/\/doi.org\/10.1177\/0310057x1204000410","relation":{},"ISSN":["0310-057X","1448-0271"],"issn-type":[{"value":"0310-057X","type":"print"},{"value":"1448-0271","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,7]]}}}