{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T23:16:57Z","timestamp":1781651817218,"version":"3.54.5"},"reference-count":19,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2016,9,1]],"date-time":"2016-09-01T00:00:00Z","timestamp":1472688000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Anaesth Intensive Care"],"published-print":{"date-parts":[[2016,9]]},"abstract":"<jats:p>\n                    This prospective, randomised study was conducted to assess the effect of flexible laryngeal mask airway (FLMA) size on oropharyngeal leak pressure (OLP) in children at the recommended intracuff pressure. A total of 120 children undergoing elective ophthalmic surgery were randomly assigned to the size 2 FLMA group or size 2.5 FLMA group. The primary measurement was OLP at an intracuff pressure of 40 cmH\n                    <jats:sub>2<\/jats:sub>\n                    O. Secondary outcomes included the incidence of OLP &lt;10 cmH\n                    <jats:sub>2<\/jats:sub>\n                    O, insufficient ventilation, gastric insufflation, insertion time, successful first-attempt insertion rate, fibreoptic view grade and pharyngolaryngeal adverse events. The median OLP was comparable for the size 2 and size 2.5 FLMA (18 cmH\n                    <jats:sub>2<\/jats:sub>\n                    O versus 18 cmH\n                    <jats:sub>2<\/jats:sub>\n                    O, P=0.38). However, the size 2 FLMA group had a higher incidence of OLP &lt;10 cmH\n                    <jats:sub>2<\/jats:sub>\n                    O and insufficient ventilation (13.3% versus 0, P=0.006). In subgroup analyses based on weight, the size 2.5 FLMA had a lower occurrence of OLP &lt;10 cmH\n                    <jats:sub>2<\/jats:sub>\n                    O and insufficient ventilation (27% versus 0, P=0.0046) in children 16\u201320 kg. We conclude that at a 40 cmH\n                    <jats:sub>2<\/jats:sub>\n                    O intracuff pressure, the OLP with the size 2 and size 2.5 FLMA was similar in children weighing 10\u201315.9 kg. However, in children weighing 16\u201320 kg, size 2 devices had a higher incidence of low OLP and insufficient ventilation, so a 2.5 FLMA may be preferable in this subgroup.\n                  <\/jats:p>","DOI":"10.1177\/0310057x1604400506","type":"journal-article","created":{"date-parts":[[2019,1,23]],"date-time":"2019-01-23T00:32:37Z","timestamp":1548203557000},"page":"593-598","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":3,"title":["Optimal Flexible Laryngeal Mask Airway Size in Children Weighing 10 to 20 kg"],"prefix":"10.1177","volume":"44","author":[{"given":"K. Z.","family":"Chen","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Shanghai Eye, Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T. J.","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Shanghai Eye, Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W. X.","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Shanghai Eye, Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"X.","family":"Shen","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Shanghai Eye, Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2016,9,1]]},"reference":[{"key":"bibr1-0310057X1604400506","unstructured":"The Laryngeal Mask Company. From http:\/\/www.lmaco.com\/LMAAirwayManagement\/LMA-FlexibleTM-IFU.pdf. Accessed 2015."},{"key":"bibr2-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-199609000-00062"},{"key":"bibr3-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.1998.00403.x"},{"key":"bibr4-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1597\/1545-1569_2003_040_0606_dotoci_2.0.co_2"},{"key":"bibr5-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X0203000609"},{"key":"bibr6-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2010.03277.x"},{"key":"bibr7-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2001.00649.x"},{"key":"bibr8-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2012.07072.x"},{"key":"bibr9-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1111\/pan.12145"},{"key":"bibr10-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1007\/s12630-011-9514-6"},{"key":"bibr11-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/80.4.470"},{"key":"bibr12-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1993.tb06968.x"},{"key":"bibr13-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-200111000-00064"},{"key":"bibr14-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1097\/00003643-200301000-00012"},{"key":"bibr15-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1016\/0952-8180(95)00229-4"},{"key":"bibr16-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1111\/j.0265-0215.1998.00257.x"},{"key":"bibr17-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2009.02968.x"},{"key":"bibr18-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2009.06160.x"},{"key":"bibr19-0310057X1604400506","doi-asserted-by":"publisher","DOI":"10.1007\/BF03013546"}],"container-title":["Anaesthesia and Intensive Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0310057X1604400506","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0310057X1604400506","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T09:09:24Z","timestamp":1777367364000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0310057X1604400506"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2016,9]]}},"alternative-id":["10.1177\/0310057X1604400506"],"URL":"https:\/\/doi.org\/10.1177\/0310057x1604400506","relation":{},"ISSN":["0310-057X","1448-0271"],"issn-type":[{"value":"0310-057X","type":"print"},{"value":"1448-0271","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,9]]}}}