{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T12:06:15Z","timestamp":1777377975257,"version":"3.51.4"},"reference-count":69,"publisher":"SAGE Publications","issue":"1_suppl","license":[{"start":{"date-parts":[[2017,7,1]],"date-time":"2017-07-01T00:00:00Z","timestamp":1498867200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Anaesth Intensive Care"],"published-print":{"date-parts":[[2017,7]]},"abstract":"<jats:p>In 1983 a patient at The Alfred Hospital, Melbourne died during general anaesthesia for emergency surgery, in the weeks following maintenance to the operating theatre gas supply. In the ensuing investigation, it was revealed that he had been given 100% nitrous oxide throughout the anaesthetic due to the inadvertent crossing of the nitrous oxide and oxygen pipelines during the repair work. In this article we review the published literature on the delivery of hypoxic and anoxic gas mixtures, and the associated morbidity and mortality. We explore the developments that took place in the delivery of anaesthetic gases, and the unforeseen dangers associated with these advances. We consider the risks to patient safety when technological advances outpaced the implementation of essential safety standards. We investigate the events that pushed the development of safer standards of anaesthetic practice and patient monitoring, which have contributed to modern day theatre practice. Finally, we consider the risks that still exist in the hospital environment, and the need for on-going vigilance.<\/jats:p>","DOI":"10.1177\/0310057x170450s104","type":"journal-article","created":{"date-parts":[[2019,1,16]],"date-time":"2019-01-16T04:37:48Z","timestamp":1547613468000},"page":"21-28","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":7,"title":["Delivery of Anoxic Gas Mixtures in Anaesthesia: Case Report and Review of the Struggle towards Safer Standards of Care"],"prefix":"10.1177","volume":"45","author":[{"given":"M.","family":"Pauling","sequence":"first","affiliation":[{"name":"Department of Anaesthesia and Perioperative Medicine, The Alfred Hospital, Melbourne, Victoria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C. M.","family":"Ball","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia and Perioperative Medicine, The Alfred Hospital and Monash University, Melbourne, Victoria"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2017,7,1]]},"reference":[{"key":"bibr1-0310057X170450S104","unstructured":"Man given wrong gas in surgery, Coroner told. The Age. 9 March 1984. From http:\/\/www.newspapers.com\/newspage\/122149561\/ Accessed 25 April 2017."},{"key":"bibr2-0310057X170450S104","unstructured":"Melbourne Coroners Court Record. VPRS 10010. P0002\/980(1984)."},{"key":"bibr3-0310057X170450S104","unstructured":"Bankstown-Lidcombe Medical Gases Incident. From http:\/\/www.health.nsw.gov.au\/Hospitals\/Pages\/bankstown-lidcombe-incident.aspx. Accessed 11 December 2016."},{"key":"bibr4-0310057X170450S104","first-page":"145","volume":"13","year":"1870","journal-title":"Brit J Dent Sci"},{"key":"bibr5-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(02)66198-7"},{"key":"bibr6-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/57.7.640"},{"key":"bibr7-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.4103\/0019-5049.120147"},{"key":"bibr8-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-194705000-00009"},{"key":"bibr9-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(77)91000-5"},{"key":"bibr10-0310057X170450S104","first-page":"307","volume":"63","author":"Petty W.C.","year":"1995","journal-title":"AANA J"},{"key":"bibr11-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.2.4775.92"},{"key":"bibr12-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1968.tb00015.x"},{"key":"bibr13-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1986.tb12755.x"},{"key":"bibr14-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/21.3.107"},{"key":"bibr15-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1956.tb07975.x"},{"key":"bibr16-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1016\/S1522-8649(96)50024-7"},{"key":"bibr17-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1955.tb01645.x"},{"key":"bibr18-0310057X170450S104","volume-title":"Equipment for Anaesthesia and Intensive Care.","author":"Russell W.","year":"1983"},{"key":"bibr19-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/34.8.591"},{"key":"bibr20-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.14219\/jada.archive.1977.0313"},{"key":"bibr21-0310057X170450S104","first-page":"178","volume":"9","author":"Youatt G.","year":"1981","journal-title":"Anaesth Intensive Care"},{"key":"bibr22-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1986.tb12991.x"},{"key":"bibr23-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1961.tb13415.x"},{"key":"bibr24-0310057X170450S104","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1111\/j.1365-2044.2001.2369-7.x","volume":"56","author":"Thomas A.N.","year":"2001","journal-title":"Anaesthesia"},{"key":"bibr25-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2009.05951.x"},{"key":"bibr26-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1960.tb13922.x"},{"key":"bibr27-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-197209000-00031"},{"key":"bibr28-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/64.6.749"},{"key":"bibr29-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2005.04318.x"},{"key":"bibr30-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-196201000-00001"},{"key":"bibr31-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2009.06100.x"},{"key":"bibr32-0310057X170450S104","unstructured":"Information bulletin: Colour change for all medical gas cylinders. Document number IB2009-039. I July 2009. From http:\/\/www1.health.nsw.gov.au\/pds\/ActivePDSDocuments\/IB2009_039.pdf. Accessed 25 March 2017."},{"key":"bibr33-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X7800600305"},{"key":"bibr34-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/35.4.250"},{"key":"bibr35-0310057X170450S104","first-page":"171","volume":"56","author":"Wylie W.D.","year":"1975","journal-title":"Ann R Coll Surg Engl"},{"key":"bibr36-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-197604000-00007"},{"key":"bibr37-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1990.tb14364.x"},{"key":"bibr38-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1984.tb06577.x"},{"key":"bibr39-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1982.tb01282.x"},{"key":"bibr40-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1982.tb01283.x"},{"key":"bibr41-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-198102000-00012"},{"key":"bibr42-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-197503000-00023"},{"key":"bibr43-0310057X170450S104","unstructured":"HollandR. Foreign Correspondence: \u201cWrong Gas\u201d disaster in Hong Kong. Anesthesia Patient Safety Foundation Newsletter 1989; 4: 25\u20136. From http:\/\/www.apsf.org\/newsletters\/html\/1989\/fall\/ Accessed April 2017."},{"key":"bibr44-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1520\/JFS12422J"},{"key":"bibr45-0310057X170450S104","unstructured":"It could happen to you! Construction contaminates Oxygen Pipeline. Anesthesia Patient Safety Foundation Newsletter 2012. From http:\/\/www.apsf.org\/newsletters\/html\/2012\/fall\/ Accessed 25 March 2017."},{"key":"bibr46-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/40.9.692"},{"key":"bibr47-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1983.tb12201.x"},{"key":"bibr48-0310057X170450S104","first-page":"23","volume":"2","author":"Oxygen-nitrous oxide mixup hits another hospital.","year":"1977","journal-title":"Malpractice Lifeline"},{"key":"bibr49-0310057X170450S104","unstructured":"SatoT. Fatal pipeline accidents spur Japanese Standards: Classic O2-N2O pipe switch causes 2 deaths before problem caught. Anesthesia Patient Safety Foundation Newsletter. 1991; 6: 13\u201324. From http:\/\/www.apsf.org\/newsletters\/html\/1991\/summer\/ Accessed April 2017."},{"key":"bibr50-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1097\/00149078-199202010-00012"},{"key":"bibr51-0310057X170450S104","first-page":"143","volume":"22","author":"ISO\/IEC Electronic Publishing Survey.","year":"1992","journal-title":"Biomedical Safety & Standards"},{"key":"bibr52-0310057X170450S104","first-page":"848","volume":"1","author":"Editorial.","year":"1974","journal-title":"Lancet"},{"key":"bibr53-0310057X170450S104","first-page":"175","volume":"2","author":"The Westminster inquiry.","year":"1977","journal-title":"Lancet"},{"key":"bibr54-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/39.3.257"},{"key":"bibr55-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/39.11.908"},{"key":"bibr56-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1007\/BF03006878"},{"key":"bibr57-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1964.tb00423.x"},{"key":"bibr58-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1967.tb02770.x"},{"key":"bibr59-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/28.5.228"},{"key":"bibr60-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1967.tb02706.x"},{"key":"bibr61-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1965.tb04684.x"},{"key":"bibr62-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.1.5539.551"},{"key":"bibr63-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1978.tb08430.x"},{"key":"bibr64-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/50.7.641"},{"key":"bibr65-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1979.tb04870.x"},{"key":"bibr66-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.1.6174.1354"},{"key":"bibr67-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X8201000411"},{"key":"bibr68-0310057X170450S104","unstructured":"Australian Standard. Medical gas systems- installation and testing of non-flammable medical gas pipeline systems. AS 2896-2011. From https:\/\/www.ihea.org.au\/files\/vic\/presentation_as_2896.pdf Accessed April 2017."},{"key":"bibr69-0310057X170450S104","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2007.05193.x"}],"container-title":["Anaesthesia and Intensive Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0310057X170450S104","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0310057X170450S104","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T09:09:40Z","timestamp":1777367380000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0310057X170450S104"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7]]},"references-count":69,"journal-issue":{"issue":"1_suppl","published-print":{"date-parts":[[2017,7]]}},"alternative-id":["10.1177\/0310057X170450S104"],"URL":"https:\/\/doi.org\/10.1177\/0310057x170450s104","relation":{},"ISSN":["0310-057X","1448-0271"],"issn-type":[{"value":"0310-057X","type":"print"},{"value":"1448-0271","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,7]]}}}