{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T01:05:00Z","timestamp":1780967100758,"version":"3.54.1"},"reference-count":16,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2008,1,1]],"date-time":"2008-01-01T00:00:00Z","timestamp":1199145600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J Artif Organs"],"published-print":{"date-parts":[[2008,1]]},"abstract":"<jats:p>The original substitution and\/or dialysates used for continuous hemofiltration and\/or dialysis were either based on peritoneal dialysis fluids, or peritoneal dialysates themselves. Although these fluids have been refined over the years, by changing the anionic base from acetate or racemic d+ l-lactate, to bicarbonate or l-lactate, the fluids remain designed for low volume hourly exchanges. Even at relatively low volume exchanges, the composition of these fluids can affect systemic acid-base balance. Those fluids which contain a higher concentration of lactate with a corresponding lower chloride, predispose to a hypochloremic alkalosis, whereas those with a lower concentration of lactate with a corresponding higher chloride potentially lead to a hyperchloremic acidosis. In addition, cation balance, differs when using the same fluid as a replacement solution, compared to dialysate. In particular, sodium balance is greater for post-dilutional fluid replacement, due to the lower sieving coefficient.<\/jats:p>\n                  <jats:p>More recently, citrate has been introduced as an extracorporeal anticoagulant, and a variety of dialysates\/replacement fluids have been developed, due to the difference in citrate clearance between dialysis and convection based extracorporeal circuits.<\/jats:p>\n                  <jats:p>Over the last decade, there has been a general increase in the standard hourly dialysate and exchange volumes used in the management of patients with acute kidney injury, from 1 to 2.5\u20133 l\/h. Indeed, even larger volume exchanges, some 6\u20138 l\/h have been advocated to improve patient outcomes. However, before embarking on such continuous high volume exchanges, a new generation of fluids may need to be developed to prevent acid-base and electrolyte imbalances. (Int J Artif Organs 2008; 31: 3\u20135)<\/jats:p>","DOI":"10.1177\/039139880803100102","type":"journal-article","created":{"date-parts":[[2018,1,12]],"date-time":"2018-01-12T02:01:52Z","timestamp":1515722512000},"page":"3-5","source":"Crossref","is-referenced-by-count":20,"title":["Potential Adverse Effects of Replacing High Volume Hemofiltration Exchanges on Electrolyte Balance and Acid-Base Status Using the Current Commercially Available Replacement Solutions in Patients with Acute Renal Failure"],"prefix":"10.1177","volume":"31","author":[{"given":"A.","family":"Davenport","sequence":"first","affiliation":[{"name":"UCL Center for Nephrology, Royal Free and University College Medical School, Royal Free Hospital, London - England"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2018,1,10]]},"reference":[{"key":"bibr1-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1093\/ndt\/gfh880"},{"key":"bibr2-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(06)69111-3"},{"key":"bibr3-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1016\/S0272-6386(99)70068-5"},{"key":"bibr4-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-001-1159-4"},{"key":"bibr5-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1007\/BF01709839"},{"key":"bibr6-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-200201000-00016"},{"key":"bibr7-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(00)02430-2"},{"key":"bibr8-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-200210000-00005"},{"key":"bibr9-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-200011000-00001"},{"key":"bibr10-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(88)91470-5"},{"key":"bibr11-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1159\/000060099"},{"key":"bibr12-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-003-1857-1"},{"key":"bibr13-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1213\/01.ANE.0000053256.77500.9D"},{"key":"bibr14-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1159\/000078899"},{"key":"bibr15-039139880803100102","doi-asserted-by":"publisher","DOI":"10.1007\/s001340100953"},{"key":"bibr16-039139880803100102","doi-asserted-by":"publisher","DOI":"10.2215\/CJN.00040505"}],"container-title":["The International Journal of Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/039139880803100102","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/039139880803100102","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T19:39:51Z","timestamp":1777491591000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/039139880803100102"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,1]]},"references-count":16,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2008,1]]}},"alternative-id":["10.1177\/039139880803100102"],"URL":"https:\/\/doi.org\/10.1177\/039139880803100102","relation":{},"ISSN":["0391-3988","1724-6040"],"issn-type":[{"value":"0391-3988","type":"print"},{"value":"1724-6040","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,1]]}}}