{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,3]],"date-time":"2026-05-03T05:05:31Z","timestamp":1777784731998,"version":"3.51.4"},"reference-count":22,"publisher":"SAGE Publications","issue":"9","license":[{"start":{"date-parts":[[2019,5,23]],"date-time":"2019-05-23T00:00:00Z","timestamp":1558569600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Int J Artif Organs"],"published-print":{"date-parts":[[2019,9]]},"abstract":"<jats:p>In every country in the world, there are a number of amputees who have been exposed to some accidents that led to the loss of their upper limbs. The aim of this study is to suggest a system for real-time classification of five classes of shoulder girdle motions for high-level upper limb amputees using a pattern recognition system. In the suggested system, the wavelet transform was utilized for feature extraction, and the extreme learning machine was used as a classifier. The system was tested on four intact-limbed subjects and one amputee, with eight channels involving five electromyography channels and three-axis accelerometer sensor. The study shows that the suggested pattern recognition system has the ability to classify the shoulder girdle motions for high-level upper limb motions with 88.4% average classification accuracy for four intact-limbed subjects and 92.8% classification accuracy for one amputee by combining electromyography and accelerometer channels. The outcomes of this study may suggest that the proposed pattern recognition system can help to provide control signals to drive a prosthetic arm for high-level upper limb amputees.<\/jats:p>","DOI":"10.1177\/0391398819848003","type":"journal-article","created":{"date-parts":[[2019,5,23]],"date-time":"2019-05-23T03:22:56Z","timestamp":1558581776000},"page":"508-515","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":5,"title":["Real-time classification of shoulder girdle motions for multifunctional prosthetic hand control: A preliminary study"],"prefix":"10.1177","volume":"42","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4003-2619","authenticated-orcid":false,"given":"Ghaith Kadhim","family":"Sharba","sequence":"first","affiliation":[{"name":"Department of Medical Instrumentation Techniques Engineering, Electrical Engineering Technical College, Middle Technical University, Baghdad, Iraq"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mousa Kadhim","family":"Wali","sequence":"additional","affiliation":[{"name":"Department of Medical Instrumentation Techniques Engineering, Electrical Engineering Technical College, Middle Technical University, Baghdad, Iraq"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali Hussein","family":"AI-Timemy","sequence":"additional","affiliation":[{"name":"Biomedical Engineering Department, AI-Khawarizmi College of Engineering, University of Baghdad, Baghdad, Iraq"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2019,5,23]]},"reference":[{"key":"bibr1-0391398819848003","first-page":"396","volume-title":"Proceedings of the 2nd international IEEE\/EMBS conference on neural engineering","author":"Kuiken TA"},{"key":"bibr2-0391398819848003","first-page":"6914","volume-title":"Proceedings of the 31st annual international conference of the IEEE engineering in medicine and biology society","author":"Li G"},{"key":"bibr3-0391398819848003","doi-asserted-by":"publisher","DOI":"10.1016\/j.eswa.2012.02.192"},{"key":"bibr4-0391398819848003","doi-asserted-by":"publisher","DOI":"10.1109\/10.204774"},{"key":"bibr5-0391398819848003","doi-asserted-by":"publisher","DOI":"10.1016\/j.jelekin.2011.12.012"},{"key":"bibr6-0391398819848003","author":"Hussein Ali A","year":"2013","journal-title":"An investigation of electromyographic (EMG) control of dextrous hand prostheses for transradian amputees"},{"key":"bibr7-0391398819848003","first-page":"311","volume-title":"Proceedings of the IEEE international conference on rehabilitation robotics","author":"Horiuchi Y"},{"key":"bibr8-0391398819848003","volume-title":"Proceedings of the 30th annual international conference of the IEEE engineering in medicine and biology society","author":"Martelloni C"},{"key":"bibr9-0391398819848003","first-page":"2107","volume-title":"Proceedings of the 37th annual international conference of the IEEE engineering in medicine and biology society","author":"Rivela DD"},{"key":"bibr10-0391398819848003","doi-asserted-by":"publisher","DOI":"10.5772\/21763"},{"key":"bibr11-0391398819848003","doi-asserted-by":"publisher","DOI":"10.4028\/www.scientific.net\/JBBBE.31.32"},{"key":"bibr12-0391398819848003","volume-title":"Human anatomy","author":"O\u2019lauglin VD","year":"2006"},{"key":"bibr13-0391398819848003","volume-title":"Anatomy & physiology with integrated study guide","author":"Gunstream SE.","year":"2000"},{"key":"bibr14-0391398819848003","volume-title":"Cram\u2019s introduction to surface electromyography","author":"Criswell E.","year":"2011","edition":"2"},{"key":"bibr15-0391398819848003","doi-asserted-by":"publisher","DOI":"10.1109\/10.914793"},{"key":"bibr16-0391398819848003","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/297587"},{"key":"bibr17-0391398819848003","doi-asserted-by":"publisher","DOI":"10.1109\/TKDE.2007.190669"},{"key":"bibr18-0391398819848003","doi-asserted-by":"publisher","DOI":"10.1016\/j.neucom.2005.12.126"},{"key":"bibr19-0391398819848003","doi-asserted-by":"publisher","DOI":"10.1016\/j.procs.2018.01.109"},{"key":"bibr20-0391398819848003","doi-asserted-by":"publisher","DOI":"10.1007\/s10462-013-9405-z"},{"key":"bibr21-0391398819848003","doi-asserted-by":"publisher","DOI":"10.1109\/ICRA.2015.7140105"},{"key":"bibr22-0391398819848003","volume-title":"3D printed myoelectric prosthetic arm","author":"Hussein ME.","year":"2014"}],"container-title":["The International Journal of Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0391398819848003","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0391398819848003","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0391398819848003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T19:41:43Z","timestamp":1777491703000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0391398819848003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,23]]},"references-count":22,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2019,9]]}},"alternative-id":["10.1177\/0391398819848003"],"URL":"https:\/\/doi.org\/10.1177\/0391398819848003","relation":{},"ISSN":["0391-3988","1724-6040"],"issn-type":[{"value":"0391-3988","type":"print"},{"value":"1724-6040","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,23]]}}}