{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T01:38:39Z","timestamp":1789522719830,"version":"build-2803163510"},"reference-count":37,"publisher":"SAGE Publications","issue":"8","license":[{"start":{"date-parts":[[2025,6,25]],"date-time":"2025-06-25T00:00:00Z","timestamp":1750809600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,6,25]],"date-time":"2025-06-25T00:00:00Z","timestamp":1750809600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Int J Artif Organs"],"published-print":{"date-parts":[[2025,8]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Ongoing donor-organ shortage has limited transplantation making LVADs an effective alternative therapy for patients with end-stage heart failure. When LVAD-associated complications arise device exchange is a feasible and safe alternative. This study addresses the factors that impact survival post-LVAD exchange.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      Our decoded database was constructed retrospectively. Surgical details, device features, and re-intervention information were studied. The primary outcome was mortality. Kaplan-Meier estimators were used for post-pump exchange survival analysis. Pairwise log-rank tests compare the survivals between different groups within each variable.\n                      <jats:italic>p<\/jats:italic>\n                      -Value &lt;0.05 was considered significant. Backward-stepwise regression was used to construct the multivariable model using a subset of variables, retaining only variables with a\n                      <jats:italic>p<\/jats:italic>\n                      -value &lt;0.1. Hazard ratios, their 95% confidence intervals, and p-values of the significant variables were reported.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Analysis of factors impacting survival post-pump exchange study showed a poor survival probability of only primary midline-sternotomy\/redo (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.005). Multivariable analysis showed that bridging with ECMO was protective with a hazard ratio of 0.16 (0.03\u20130.86,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.03).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The overall survival probability is 50% at 4\u2009years post-pump exchange. This study highlights the differences in post-exchange outcomes depending on the device types and surgical approaches used. LVAD exchange for device-related complications can be performed in high-risk patients as a viable alternative to heart transplantation in the setting of the current heart allocation prioritization systems.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/03913988251351116","type":"journal-article","created":{"date-parts":[[2025,6,25]],"date-time":"2025-06-25T06:10:40Z","timestamp":1750831840000},"page":"566-574","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":1,"title":["Left ventricular assist device exchanges: A safe and effective strategy in the era of limited organ availability"],"prefix":"10.1177","volume":"48","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1243-4389","authenticated-orcid":false,"given":"Nandini","family":"Nair","sequence":"first","affiliation":[{"name":"Division of Cardiology, Penn State College of Medicine, Hershey, PA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenny","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Division of Cardiothoracic Surgery, Penn State College of Medicine, Hershey, PA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dongping","family":"Du","sequence":"additional","affiliation":[{"name":"IMSE, Texas Tech University, Lubbock, TX, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aditya","family":"Mahesh","sequence":"additional","affiliation":[{"name":"Division of Cardiothoracic Surgery, Penn State College of Medicine, Hershey, PA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Behzad","family":"Soleimani","sequence":"additional","affiliation":[{"name":"Division of Cardiothoracic Surgery, Penn State College of Medicine, Hershey, PA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Balakrishnan","family":"Mahesh","sequence":"additional","affiliation":[{"name":"Division of Cardiothoracic Surgery, Penn State College of Medicine, Hershey, PA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2025,6,25]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jchf.2017.02.020"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cardfail.2023.07.006"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.31083\/j.rcm2502068"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.4070\/kcj.2019.0161"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezz268"},{"issue":"5","key":"e_1_3_2_7_2","first-page":"490","article-title":"Evaluation and treatment of pump thrombosis and hemolysis","volume":"3","author":"Tchantchaleishvili V","year":"2014","unstructured":"Tchantchaleishvili V, Sagebin F, Ross RE, et al. Evaluation and treatment of pump thrombosis and hemolysis. Ann Cardiothorac Surg 2014; 3(5): 490\u2013495.","journal-title":"Ann Cardiothorac Surg"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1313385"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2022.775780"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.21037\/jtd.2018.01.115"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12055-022-01450-y"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10047-019-01127-1"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e3182703718"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/aor.13893"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.optechstcvs.2014.10.001"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2021.11.085"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2015.05.033"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.pcad.2024.01.018"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e318161d705"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.21037\/acs.2019.04.04"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/tid.12207"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2022.09.020"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/ACO.0000000000001211"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0000000000001359"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10047-019-01102-w"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.transproceed.2023.03.027"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezae317"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2012.08.031"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2024.11.032"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1111\/aor.13594"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1111\/jocs.14423"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0000000000000928"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.atssr.2023.05.002"},{"issue":"6","key":"e_1_3_2_34_2","first-page":"646","article-title":"Three-year follow-up after less-invasive left ventricular assist device exchange to HeartMate 3\u2122","volume":"62","author":"Hanke JS","year":"2021","unstructured":"Hanke JS, Mariani S, Merzah AS, et al. Three-year follow-up after less-invasive left ventricular assist device exchange to HeartMate 3\u2122. J Cardiovasc Surg 2021; 62(6): 646\u2013651.","journal-title":"J Cardiovasc Surg"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2021.09.031"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2019.09.151"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0000000000000833"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2021.11.048"}],"container-title":["The International Journal of Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/03913988251351116","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/03913988251351116","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/03913988251351116","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T19:41:26Z","timestamp":1777491686000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/03913988251351116"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,25]]},"references-count":37,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2025,8]]}},"alternative-id":["10.1177\/03913988251351116"],"URL":"https:\/\/doi.org\/10.1177\/03913988251351116","relation":{},"ISSN":["0391-3988","1724-6040"],"issn-type":[{"value":"0391-3988","type":"print"},{"value":"1724-6040","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,25]]}}}