{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T06:00:10Z","timestamp":1780898410778,"version":"3.54.1"},"reference-count":36,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T00:00:00Z","timestamp":1780099200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/501100006261","name":"Taif University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100006261","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Int J Artif Organs"],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:p>Rehabilitation exoskeletons is still an important issue to improve walking functionality and speed up treatment for patient to restore their lives faster. This paper introduces a controlled lightweight exoskeleton for lower limb rehabilitation with a friendly user interface. A model for the proposed exoskeleton design is initially developed using SolidWorks. Secondly, an optimization study is presented to minimize the total mass. Simulink model is established for the proposed exoskeleton to simulate the gait cycle. Then, a prototype is implemented using light weight material. An integrated control system based on active actuators at both hip and knee joints is presented. A simple user interface is designed to control the movements of hip and knee joints. Finally, an experimental test is performed to validate simulated data of human gait cycle for torque and angle profiles of hip and knee joints.<\/jats:p>","DOI":"10.1177\/03913988261439927","type":"journal-article","created":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T09:22:18Z","timestamp":1780132938000},"page":"411-427","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Double-leg exoskeleton for rehabilitation: Design, optimization, and implementation"],"prefix":"10.1177","volume":"49","author":[{"given":"Hasan","family":"Eleashy","sequence":"first","affiliation":[{"name":"Mechanical Engineering Department, Faculty of Engineering &amp; Technology, Future University in Egypt, Cairo, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hashem A","family":"Bukhary","sequence":"additional","affiliation":[{"name":"Department of Surgery, Orthopedic Division, Faculty of Medicine, Taif University, Taif, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khalid M","family":"Alhomayani","sequence":"additional","affiliation":[{"name":"Department of Surgery, Orthopedic Division, Faculty of Medicine, Taif University, Taif, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fahd I","family":"Aljuaid","sequence":"additional","affiliation":[{"name":"Department of Surgery, Orthopedic Division, Faculty of Medicine, Taif University, Taif, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdolrahman A","family":"Ashour","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, East Jeddah General Hospital, Ministry of Health, Jeddah, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3162-9453","authenticated-orcid":false,"given":"Mahmoud","family":"Helal","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Faculty of Engineering, Taif University, Taif, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,5,30]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.4028\/www.scientific.net\/AMM.880.95"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40430-023-04480-8"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1177\/1687814017735791"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.3390\/app12042238"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.mechmachtheory.2020.103840"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.3390\/s23136103"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.3390\/s21030781"},{"key":"e_1_3_3_9_2","first-page":"6650418","article-title":"The biomechanics and energetics of human running using an elastic knee exoskeleton","volume":"2013","author":"Elliott G","year":"2013","unstructured":"Elliott G, Sawicki GS, Marecki A, et al. The biomechanics and energetics of human running using an elastic knee exoskeleton. IEEE Int Conf Rehabil Robot 2013; 2013: 6650418.","journal-title":"IEEE Int Conf Rehabil Robot"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12541-019-00217-7"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.3390\/s19143196"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1080\/17483107.2018.1494218"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2018.2872889"},{"issue":"19","key":"e_1_3_3_14_2","first-page":"9140","article-title":"Torque analysis of the lower limb exoskeleton robot design","volume":"10","author":"Shaari NLA","year":"2015","unstructured":"Shaari NLA, Md Isa IS, Jun TC. Torque analysis of the lower limb exoskeleton robot design. ARPN J Eng Appl Sci 2015; 10(19): 9140\u20139149.","journal-title":"ARPN J Eng Appl Sci"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.3390\/s111211305"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1109\/IROS.2009.5354543"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1186\/1743-0003-6-19"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1186\/1743-0003-6-23"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.3390\/s20092705"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.3390\/mi10070463"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1109\/ROBOT.2004.1307425"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.1109\/ICRA.2015.7139979"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1109\/ICORR.2015.7281301"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1109\/ICInfA.2013.6720360"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2012.2219065"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2013.2248749"},{"issue":"6","key":"e_1_3_3_27_2","article-title":"Structural design and modal analysis of exoskeleton robot for rehabilitation of lower limb","volume":"1087","author":"Yang K","year":"2018","unstructured":"Yang K, Jiang QF, Wang XL, et al. Structural design and modal analysis of exoskeleton robot for rehabilitation of lower limb. J Phys Conf Ser 2018; 1087(6): 062004.","journal-title":"J Phys Conf Ser"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-01845-4_12"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/1069\/1\/012160"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/1633\/1\/012052"},{"key":"e_1_3_3_31_2","doi-asserted-by":"crossref","unstructured":"Li Y Wang X Xu P et al. SolidWorks\/SimMechanics-based lower extremity exoskeleton modeling procedure for rehabilitation. In: World congress on medical physics and biomedical engineering (ed Long M) Beijing China 26\u201331 May 2012. IFMBE proceedings vol. 39. Berlin\/Heidelberg: Springer www.springerlink.com","DOI":"10.1007\/978-3-642-29305-4_540"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00502-013-0133-5"},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.pisc.2016.04.072"},{"key":"e_1_3_3_34_2","doi-asserted-by":"publisher","DOI":"10.1109\/CONIELECOMP.2013.6525786"},{"key":"e_1_3_3_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.proeng.2011.08.043"},{"key":"e_1_3_3_36_2","first-page":"139","article-title":"Computer Vision-Based Approach for Automated Monitoring and Assessment of Gait Rehabilitation at Home","volume":"19","author":"Talaa Safae","year":"2023","unstructured":"Talaa Safae, Fezazi El, Mohamed Jilbab A et al. Computer Vision-Based Approach for Automated Monitoring and Assessment of Gait Rehabilitation at Home, International Journal of Online and Biomedical Engineering (iJOE)., 2023, Vol.19, No.18,pp 139-157. doi:10.3991\/ijoe.v19i18.43943.","journal-title":"International Journal of Online and Biomedical Engineering"},{"key":"e_1_3_3_37_2","doi-asserted-by":"crossref","unstructured":"Grimmer Martin Eslamy Mahdy Seyfarth Andre Energetic and Peak Power Advantages of Series Elastic Actuators in an Actuated Prosthetic Leg for Walking and Running. Actuators 2014 3 1-19. Doi: 10.3390\/act3010001.","DOI":"10.3390\/act3010001"}],"container-title":["The International Journal of Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/03913988261439927","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/03913988261439927","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/03913988261439927","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T05:39:23Z","timestamp":1780897163000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/03913988261439927"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,30]]},"references-count":36,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["10.1177\/03913988261439927"],"URL":"https:\/\/doi.org\/10.1177\/03913988261439927","relation":{},"ISSN":["0391-3988","1724-6040"],"issn-type":[{"value":"0391-3988","type":"print"},{"value":"1724-6040","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,30]]}}}