{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T07:04:01Z","timestamp":1784531041183,"version":"3.55.0"},"reference-count":56,"publisher":"SAGE Publications","issue":"8","license":[{"start":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T00:00:00Z","timestamp":1782691200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Int J Artif Organs"],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:p>Arteriovenous fistula (AVF) failure in hemodialysis patients is strongly influenced by local hemodynamic factors such as elevated wall shear stress, flow separation, and vortex formation. In this study, computational fluid dynamics (CFD) simulations are performed to investigate the influence of anastomosis angle and blood rheology on AVF hemodynamics. Three non-Newtonian blood models (Carreau, power-law, and Casson) are first evaluated at 45\u00b0, 90\u00b0, and 135\u00b0 anastomosis angles and validated against available experimental data. Based on shear stress prediction accuracy, the Carreau model is demonstrated as the best agreement and is selected for further simulations. Subsequently, AVFs with 45\u00b0, 90\u00b0, 110\u00b0, 120\u00b0, 135\u00b0, 145\u00b0, and 160\u00b0 anastomosis angles are analyzed under maximum, medium, and minimum pulsatile flow conditions. Hemodynamic parameters including velocity patterns, wall shear stress distribution, vortex formation, and pressure drop between the proximal artery and vein are evaluated. Results indicate that increasing the anastomosis angle significantly reduces maximum wall shear stress, high-shear regions, vortex intensity, and pressure drop. Compared with the 45\u00b0 configuration, the 160\u00b0 angle reduced maximum shear stress by ~78% under peak flow conditions. Overall, obtuse anastomosis angles demonstrated improved hemodynamic performance, suggesting that larger angles may reduce thrombosis risk and cardiovascular burden in hemodialysis patients. Considering both hemodynamic performance and surgical feasibility, the 120\u00b0 configuration is proposed as a clinically practical and effective option.<\/jats:p>","DOI":"10.1177\/03913988261455782","type":"journal-article","created":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T08:20:36Z","timestamp":1782721236000},"page":"520-535","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of arteriovenous fistulas of obtuse anastomosis in reducing thrombosis using computational fluid dynamics"],"prefix":"10.1177","volume":"49","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-9969-6592","authenticated-orcid":false,"given":"Milad","family":"Rostami","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Central Tehran Branch, Islamic Azad University, Tehran, Islamic Republic of Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-3733-0092","authenticated-orcid":false,"given":"Majid","family":"Abdolalinezhad","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Sharif University of Technology, Tehran, Islamic Republic of Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-3587-9830","authenticated-orcid":false,"given":"Mohsen","family":"Hashemi","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Islamic Republic of Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0327-6323","authenticated-orcid":false,"given":"Mohammad Amin","family":"Rahimi","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Iran University of Science and Technology, Tehran, Islamic Republic of Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,6,29]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s13239-017-0307-0"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.2147\/IJNRD.S46643"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2015.04.013"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s13239-017-0321-2"},{"issue":"2","key":"e_1_3_2_6_2","first-page":"238","article-title":"\u201cSmooth loop\u201d arteriovenous fistulas for hemodialysis","volume":"75","author":"Karmody AM","year":"1974","unstructured":"Karmody AM, Lempert N. \u201cSmooth loop\u201d arteriovenous fistulas for hemodialysis. Surgery 1974; 75(2): 238\u2013242.","journal-title":"Surgery"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-27458-9_5"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1053\/ajkd.2002.33394"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1093\/ndt\/gft068"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.282.21.2035"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1007\/s13239-011-0045-7"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s13239-017-0318-x"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1177\/1129729820944069"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1177\/0954411920926077"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2019.105203"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1093\/ndt\/gfr342"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1063\/1.4704276"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2012.10.070"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1007\/s13239-015-0246-6"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.4236\/jbise.2015.83013"},{"key":"e_1_3_2_21_2","unstructured":"Bozzetto M Ene-Iordache B Brambilla P Remuzzi A. Characterization of the flow-field in a patient-specific model of arteriovenous fistula for hemodialysis. InInternational CAE Conference 2016."},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2012.09.005"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/aor.12879"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10237-017-0973-8"},{"key":"e_1_3_2_25_2","doi-asserted-by":"crossref","unstructured":"Santos Willyam Brito de Almeida. \u201cAnalysis of pulsatile flow in arteriovenous fistula through numerical simulation.\u201d (2018).","DOI":"10.26678\/ABCM.ENEBI2018.EEB18-0037"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/nep.13219"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4043448"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1177\/039139880202500206"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.5301\/ijao.5000310"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.5301\/ijao.5000242"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2009.00930.x"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1111\/aor.13949"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12206-016-1118-1"},{"key":"e_1_3_2_34_2","volume-title":"Turbulence modeling for CFD","author":"Wilcox DC.","year":"1998","unstructured":"Wilcox DC. Turbulence modeling for CFD. La Canada Flintridge, CA: DCW Industries, 1998."},{"key":"e_1_3_2_35_2","volume-title":"Tackling turbulent flows in engineering","author":"Dewan A.","year":"2010","unstructured":"Dewan A. Tackling turbulent flows in engineering. Berlin: Springer, 2010."},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2011.04.023"},{"key":"e_1_3_2_37_2","volume-title":"Non-Newtonian models in OpenFOAM implementation of a non-Newtonian model","author":"Hamedi N","year":"2014","unstructured":"Hamedi N, Busch S. Non-Newtonian models in OpenFOAM implementation of a non-Newtonian model. Lund: Lund University, 2014."},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.3233\/BIR-1991-283-415"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jnnfm.2015.11.006"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.bbe.2017.05.006"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2005.01.034"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2003.09.016"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.3233\/BME-191067"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.3233\/THC-161132"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40430-020-02608-8"},{"key":"e_1_3_2_46_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijmecsci.2018.10.046"},{"key":"e_1_3_2_47_2","volume-title":"An introduction to computational fluid dynamics: the finite volume method","author":"Versteeg HK","year":"2007","unstructured":"Versteeg HK, Malalasekera W. An introduction to computational fluid dynamics: the finite volume method. London: Pearson Education, 2007."},{"key":"e_1_3_2_48_2","doi-asserted-by":"publisher","DOI":"10.1201\/9781482234213"},{"key":"e_1_3_2_49_2","volume-title":"CD-Laboratory-Particulate Flow Modelling","author":"Holzinger G","year":"2015","unstructured":"Holzinger G. OpenFOAM a little user-manual. CD-Laboratory-Particulate Flow Modelling, Johannes Keplper University: Linz, Austria. 2015 Mar."},{"key":"e_1_3_2_50_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-198508000-00015"},{"key":"e_1_3_2_51_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0049-3848(01)00344-9"},{"key":"e_1_3_2_52_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1538-7836.2004.00907.x"},{"key":"e_1_3_2_53_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1985.tb11855.x"},{"key":"e_1_3_2_54_2","doi-asserted-by":"publisher","DOI":"10.4155\/fso.15.28"},{"key":"e_1_3_2_55_2","doi-asserted-by":"publisher","DOI":"10.1016\/0026-2862(73)90069-1"},{"key":"e_1_3_2_56_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2014.12.050"},{"key":"e_1_3_2_57_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.ki.5001975"}],"container-title":["The International Journal of Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/03913988261455782","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/03913988261455782","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/03913988261455782","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T06:24:35Z","timestamp":1784528675000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/03913988261455782"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,29]]},"references-count":56,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["10.1177\/03913988261455782"],"URL":"https:\/\/doi.org\/10.1177\/03913988261455782","relation":{},"ISSN":["0391-3988","1724-6040"],"issn-type":[{"value":"0391-3988","type":"print"},{"value":"1724-6040","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,29]]}}}