{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T13:54:19Z","timestamp":1791035659107,"version":"4.1.0"},"reference-count":23,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T00:00:00Z","timestamp":1790640000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Int J Artif Organs"],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Total talar replacement (TTR) is an emerging treatment for end-stage talar diseases, although concerns persist regarding ankle stability due to essential ligament transection. Further investigation is necessary regarding the biomechanical impact of patient-specific total talar prosthesis (TTP) on ankle stability and bone-implant mechanics.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>The purpose of this study is designing a patient-specific TTP and assess its biomechanical performance on ankle stability and stress distribution under various loading conditions using finite element analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A CT scan is used to create a 3D finite element model of the foot and ankle complex. The TTP made of A dual-material (UHMWPE talar body and titanium alloy cage) was created and fixed with five screws. Four loading conditions were simulated: inversion, eversion, dorsiflexion, and plantarflexion, with forces of 10\u2009N, 50\u2009N, 100\u2009N, and 150\u2009N. Talar tilt angles and von Mises stresses were examined for intact and implanted models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>In comparison to the intact ankle, TTR significantly decreased the talar tilt angles in inversion (12.5%\u201316%), eversion (6.6%\u201314%), and dorsiflexion (33%\u201347%). On the other hand, plantarflexion produced a larger tilt (34%\u201344%). While bone stresses stayed below 5\u2009MPa, maximum implant stresses ranged from 20 to 80\u2009MPa. The validation of the model against cadaveric studies was reliable.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The patient-specific TTP with screw fixation improves ankle stability in most loading directions, potentially compensating for ligament insufficiency. However, greater plantarflexion instability necessitates post-operative measures. These findings provide biomechanical evidence that fixation-enhanced TTP designs can improve therapeutic outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/03913988261486195","type":"journal-article","created":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T11:21:51Z","timestamp":1790680911000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Design and biomechanical investigation of a patient-specific total talar prosthesis for total talar replacement: A finite element analysis"],"prefix":"10.1177","author":[{"given":"Md. Qumar","family":"Tabrej","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, NIT Patna, Bihar, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amit","family":"Kumar","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, NIT Patna, Bihar, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8375-0947","authenticated-orcid":false,"given":"Jayanta Kumar","family":"Biswas","sequence":"additional","affiliation":[{"name":"Department of Mechatronics and Automation Engineering, NIT Patna, Bihar, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,9,29]]},"reference":[{"key":"e_1_3_2_2_2","first-page":"44","article-title":"Epidemiology of ankle arthritis: report of a consecutive series of 639 patients from a tertiary orthopaedic centre","volume":"25","author":"Saltzman CL","year":"2005","unstructured":"Saltzman CL, Salamon ML, Blanchard GM, et al. Epidemiology of ankle arthritis: report of a consecutive series of 639 patients from a tertiary orthopaedic centre. Iowa Orthop J 2005; 25: 44\u201346.","journal-title":"Iowa Orthop J"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.N.01272"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/BTF.0000000000000203"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/1071100720948461"},{"key":"e_1_3_2_6_2","article-title":"Effects of ankle arthrodesis on biomechanical performance of the entire foot","volume":"10","author":"Wang Y","year":"2015","unstructured":"Wang Y, Li Z, Wong DW-C, et al. Effects of ankle arthrodesis on biomechanical performance of the entire foot. PLoS One 2015; 10, e0134340.","journal-title":"PLoS One"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jot.2017.12.003"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.jfas.2020.01.012"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.21.00922"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.jfas.2020.08.013"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.25237"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/036354658501300502"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jos.2022.08.008"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1615\/IntJMultCompEng.2021039785"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1177\/03913988251414995"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1177\/03913988211001875"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200612000-00018"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jot.2022.07.013"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jos.2022.08.008"},{"key":"e_1_3_2_20_2","doi-asserted-by":"crossref","unstructured":"Biswas JK Kalita K Roychowdhury A. Symbolic regression metamodel-based optimal design of patient-specific spinal implant (pedicle screw fixation). Engineering with Computers 2022; 38(2): 999\u20131014.","DOI":"10.1007\/s00366-020-01090-z"},{"key":"e_1_3_2_21_2","article-title":"The role of the depth of resection of the distal tibia on biomechanical performance of the tibial component for TAR: a finite element analysis with three implant designs","volume":"119","author":"Ghosh R.","year":"2023","unstructured":"Ghosh R. The role of the depth of resection of the distal tibia on biomechanical performance of the tibial component for TAR: a finite element analysis with three implant designs. Med Eng Phys 2023; 119: 104034.","journal-title":"Med Eng Phys"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4068008"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2018.04.010"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2021.104368"}],"container-title":["The International Journal of Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/03913988261486195","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/03913988261486195","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/03913988261486195","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T13:17:19Z","timestamp":1791033439000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/03913988261486195"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,29]]},"references-count":23,"alternative-id":["10.1177\/03913988261486195"],"URL":"https:\/\/doi.org\/10.1177\/03913988261486195","relation":{},"ISSN":["0391-3988","1724-6040"],"issn-type":[{"value":"0391-3988","type":"print"},{"value":"1724-6040","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,29]]},"article-number":"03913988261486195"}}