{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,3]],"date-time":"2025-03-03T05:36:13Z","timestamp":1740980173290,"version":"3.38.0"},"reference-count":19,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2019,5,22]],"date-time":"2019-05-22T00:00:00Z","timestamp":1558483200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Urologia"],"published-print":{"date-parts":[[2019,11]]},"abstract":"<jats:sec><jats:title>Background:<\/jats:title><jats:p> The purpose of this study is to investigate the representativeness of the conventional laparoscopic standard box trainers in terms of real-life circumstances in transperitoneal laparoscopical interventions of the upper tract, using questionnaire inquiries with experienced surgeons. <\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and methods:<\/jats:title><jats:p> The study was conducted with 44 laparoscopists, whose level of renal surgery experience was either high (primary surgeon in &gt;100 cases), moderate (primary surgeon in &gt;50 cases) or basic (primary surgeon in &gt;20 cases). We used the box widely preferred in international training courses, which consists of a 10-mm 30\u00b0 laparoscope, real endoscopic instruments, light source, monitor and chicken bone materials. Participants were asked whether they represent real-life situations while performing tasks by means of standard box trainers. <\/jats:p><\/jats:sec><jats:sec><jats:title>Results:<\/jats:title><jats:p> The medians of \u2018restrained body posture of the surgeon\u2019, \u2018position of monitor\u2019, \u2018trocars entry slots\u2019, \u2018tissue distance and region\u2019 and \u2018limited field of movement and restricted working space\u2019 were analysed on their difference from the ideal value. All the variables were shown to be significantly different from the ideal value of 5 (p\u2009&lt;\u20090.001). These results suggest that experienced surgeons in our study did not find the box simulation conditions similar to real surgery conditions. <\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion:<\/jats:title><jats:p> Conventional laparoscopic trainer box, which is currently being used, is far from representing for the real situation in transperitoneal laparoscopical interventions of the upper tract. <\/jats:p><\/jats:sec>","DOI":"10.1177\/0391560319850428","type":"journal-article","created":{"date-parts":[[2019,5,22]],"date-time":"2019-05-22T17:32:00Z","timestamp":1558546320000},"page":"202-206","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Do \u2018standard laparoscopic box trainers\u2019 represent real-life conditions during transperitoneal laparoscopical interventions of the upper tract?"],"prefix":"10.1177","volume":"86","author":[{"given":"Tuncay","family":"Tas","sequence":"first","affiliation":[{"name":"\u0130stanbul Cerrahi Hospital, \u0130stanbul Esenyurt University, \u0130stanbul,Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5337-5226","authenticated-orcid":false,"given":"Basri","family":"Cakiroglu","sequence":"additional","affiliation":[{"name":"Hisar Intercontinental Hospital, \u00dcmraniye, \u0130stanbul,Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2019,5,22]]},"reference":[{"key":"bibr1-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1089\/end.2007.9983"},{"key":"bibr2-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjsurg.2004.04.008"},{"key":"bibr3-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1016\/j.eururo.2004.12.007"},{"key":"bibr4-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1089\/089277901300189330"},{"key":"bibr5-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1016\/j.eururo.2008.09.045"},{"key":"bibr6-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1089\/end.2005.19.541"},{"key":"bibr7-0391560319850428","first-page":"13","author":"Doublet JD","year":"2002","journal-title":"EAU-Guidelines"},{"key":"bibr8-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1016\/j.eururo.2004.10.017"},{"key":"bibr9-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsurg.2016.12.009"},{"key":"bibr10-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1089\/end.2012.0239"},{"key":"bibr11-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1016\/j.juro.2013.03.115"},{"key":"bibr12-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-410X.2009.09193.x"},{"key":"bibr13-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1089\/end.2015.0561"},{"key":"bibr14-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1016\/S1072-7515(00)00339-2"},{"key":"bibr15-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1159\/000072684"},{"key":"bibr16-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1089\/end.2010.0005"},{"key":"bibr17-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1089\/end.2006.20.69"},{"key":"bibr18-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1089\/end.2008.0058"},{"key":"bibr19-0391560319850428","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsurg.2017.05.013"}],"container-title":["Urologia Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0391560319850428","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0391560319850428","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0391560319850428","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,2]],"date-time":"2025-03-02T10:44:45Z","timestamp":1740912285000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0391560319850428"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,22]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,11]]}},"alternative-id":["10.1177\/0391560319850428"],"URL":"https:\/\/doi.org\/10.1177\/0391560319850428","relation":{},"ISSN":["0391-5603","1724-6075"],"issn-type":[{"type":"print","value":"0391-5603"},{"type":"electronic","value":"1724-6075"}],"subject":[],"published":{"date-parts":[[2019,5,22]]}}}