{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T09:37:10Z","timestamp":1792143430260,"version":"4.4.0"},"reference-count":85,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2020,2,28]],"date-time":"2020-02-28T00:00:00Z","timestamp":1582848000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Can Assoc Radiol J"],"published-print":{"date-parts":[[2020,8]]},"abstract":"<jats:p>Dual-energy computed tomography (CT) is a promising tool with increasing availability and multiple emerging and established clinical applications in neuroradiology. With its ability to allow characterization of materials based on their differential attenuation when imaged at two different energy levels, dual-energy CT can help identify the composition of brain, neck, and spinal components. Virtual monoenergetic imaging allows a range of simulated single energy-level reconstructions to be created with postprocessing. Low-energy reconstructions can aid identification of edema, ischemia, and subtle lesions due to increased soft tissue contrast as well as increasing contrast-to-noise ratios on angiographic imaging. Higher energy reconstructions can reduce image artifact from dental amalgam, aneurysm clips and coils, spinal hardware, dense contrast, and dense bones. Differentiating iodine from hemorrhage may help guide management of patients after thrombectomy and aid diagnosis of enhancing tumors within parenchymal hemorrhages. Iodine quantification may predict hematoma expansion in aneurysmal bleeds and outcomes in traumatic brain injury. Calcium and bone subtraction can be used to distinguish hemorrhage from brain parenchymal mineralization as well as improving visualization of extra-axial lesions and vessels adjacent to dense plaque or skull. This article reviews the basics of dual-energy CT and highlights many of its clinical applications in the evaluation of acute neurological presentations.<\/jats:p>","DOI":"10.1177\/0846537120904347","type":"journal-article","created":{"date-parts":[[2020,2,28]],"date-time":"2020-02-28T04:13:17Z","timestamp":1582863197000},"page":"253-265","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":40,"title":["A Review of the Applications of Dual-Energy CT in Acute Neuroimaging"],"prefix":"10.1177","volume":"71","author":[{"given":"Brian","family":"Gibney","sequence":"first","affiliation":[{"name":"Division of Emergency Radiology, Vancouver General Hospital, Vancouver, British Columbia, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ciaran E.","family":"Redmond","sequence":"additional","affiliation":[{"name":"Division of Emergency Radiology, Vancouver General Hospital, Vancouver, British Columbia, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8168-2159","authenticated-orcid":false,"given":"Danielle","family":"Byrne","sequence":"additional","affiliation":[{"name":"Division of Neuroradiology, Vancouver General Hospital, Vancouver, British Columbia, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7334-3341","authenticated-orcid":false,"given":"Shobhit","family":"Mathur","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, St Michael\u2019s Hospital, University of Toronto, Toronto, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas","family":"Murray","sequence":"additional","affiliation":[{"name":"Division of Emergency Radiology, Vancouver General Hospital, Vancouver, British Columbia, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2020,2,28]]},"reference":[{"key":"bibr1-0846537120904347","unstructured":"McFarland S. Half A Century In CT: How Computed Tomography Has Evolved\u2014ISCT [Internet]. ISCT. ISCT; 2016. https:\/\/www.isct.org\/computed-tomography-blog\/2017\/2\/10\/half-a-century-in-ct-how-computed-tomography-has-evolved. Accessed December 9, 2019."},{"key":"bibr2-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1713973"},{"key":"bibr3-0846537120904347","doi-asserted-by":"crossref","unstructured":"Hoyt DB, Holcomb J, Abraham E, Atkins J, Sopko G. Working group on Trauma research program summary report [Internet]. J Trauma: Injury, Infect Crit Care. 2004;57:410\u2013415. http:\/\/dx.doi.org\/10.1097\/00005373-200408000-00038","DOI":"10.1097\/00005373-200408000-00038"},{"issue":"8","key":"bibr4-0846537120904347","first-page":"1619","volume":"28","author":"Davis PC","year":"2007","journal-title":"AJNR Am J Neuroradiol"},{"key":"bibr5-0846537120904347","doi-asserted-by":"crossref","unstructured":"McCollough CH, Leng S, Yu L, Fletcher JG. Dual- and multi-energy CT: principles, technical approaches, and clinical applications [Internet]. Radiology. 2015;276:637\u2013653. http:\/\/dx.doi.org\/10.1148\/radiol.2015142631","DOI":"10.1148\/radiol.2015142631"},{"key":"bibr6-0846537120904347","volume-title":"The Essential Physics of the Medical Imaging","author":"Bushberg JT","year":"2012","edition":"3"},{"key":"bibr7-0846537120904347","unstructured":"Gupta AK, Chowdhury V, Khandelwal N. Diagnostic radiology: Recent Advances and Applied Physics in Imaging, 2nd ed. New Delhi, India: JP Medical Ltd; 2013:438."},{"key":"bibr8-0846537120904347","doi-asserted-by":"crossref","unstructured":"Siegel MJ, Kaza RK, Bolus DN, et al. White paper of the society of computed body tomography and magnetic resonance on dual-energy CT, Part 1 [Internet]. J Comput Assist Tomogr. 2016;40(6):841\u2013845. http:\/\/dx.doi.org\/10.1097\/rct.0000000000000531","DOI":"10.1097\/RCT.0000000000000531"},{"key":"bibr9-0846537120904347","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.09.2737"},{"key":"bibr10-0846537120904347","doi-asserted-by":"crossref","unstructured":"Liu X, Yu L, Primak AN, McCollough CH. Quantitative imaging of element composition and mass fraction using dual-energy CT: three-material decomposition [Internet]. Med Phys. 2009;36(5):1602\u20131609. http:\/\/dx.doi.org\/10.1118\/1.3097632","DOI":"10.1118\/1.3097632"},{"key":"bibr11-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1007\/s10140-017-1558-7"},{"key":"bibr12-0846537120904347","doi-asserted-by":"crossref","unstructured":"Yu L, Christner JA, Leng S, Wang J, Fletcher JG, McCollough CH. Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality [Internet]. Med Phys. 2011;38(12):6371\u20136379. http:\/\/dx.doi.org\/10.1118\/1.3658568","DOI":"10.1118\/1.3658568"},{"key":"bibr13-0846537120904347","doi-asserted-by":"crossref","unstructured":"Suntharalingam S, Stenzel E, Wetter A, et al. Third generation dual-energy CT with 80\/150 Sn kV for head and neck tumor imaging [Internet]. Acta Radiologica. 2019;60(5):586\u2013592. http:\/\/dx.doi.org\/10.1177\/0284185118788896","DOI":"10.1177\/0284185118788896"},{"key":"bibr14-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinimag.2019.02.005"},{"key":"bibr15-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2019.01.011"},{"key":"bibr16-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2011.02.023"},{"key":"bibr17-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000367"},{"key":"bibr18-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.12111604"},{"key":"bibr19-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-017-3908-8"},{"key":"bibr20-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1016\/j.neurad.2016.04.001"},{"key":"bibr21-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2018.09.010"},{"key":"bibr22-0846537120904347","first-page":"20180850","author":"Karino T","year":"2019","journal-title":"Br J Radiol"},{"key":"bibr23-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000011670"},{"key":"bibr24-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0090658"},{"key":"bibr25-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2019182870"},{"key":"bibr26-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1148\/rg.2019190142"},{"key":"bibr27-0846537120904347","doi-asserted-by":"crossref","unstructured":"Schr\u00f6der J, Thomalla G. A critical review of Alberta stroke program early CT score for evaluation of acute stroke imaging [Internet]. Front Neurol. 2017;7:245. http:\/\/dx.doi.org\/10.3389\/fneur.2016.00245","DOI":"10.3389\/fneur.2016.00245"},{"key":"bibr28-0846537120904347","doi-asserted-by":"crossref","unstructured":"Gupta AC, Schaefer PW, Chaudhry ZA, et al. Interobserver reliability of Baseline Noncontrast CT Alberta stroke Program Early CT score for intra-arterial stroke treatment selection [Internet]. Am J Neuroradiol. 2012;33(6):1046\u20131049. http:\/\/dx.doi.org\/10.3174\/ajnr.a2942","DOI":"10.3174\/ajnr.A2942"},{"key":"bibr29-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2016-012331"},{"key":"bibr30-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000461"},{"key":"bibr31-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1016\/j.jstrokecerebrovasdis.2016.08.025"},{"key":"bibr32-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000413"},{"key":"bibr33-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1161\/STR.0000000000000211"},{"key":"bibr34-0846537120904347","doi-asserted-by":"crossref","unstructured":"Tijssen MPM, Hofman PAM, Stadler AAR, et al. The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke [Internet]. Eur Radiol. 2014;24(4):834\u2013840. http:\/\/dx.doi.org\/10.1007\/s00330-013-3073-x","DOI":"10.1007\/s00330-013-3073-x"},{"key":"bibr35-0846537120904347","doi-asserted-by":"publisher","DOI":"10.14336\/AD.2018.0807"},{"key":"bibr36-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.0000000000008093"},{"key":"bibr37-0846537120904347","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5513"},{"key":"bibr38-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1177\/1591019919880425"},{"key":"bibr39-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2018-014486"},{"key":"bibr40-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2015-011988"},{"key":"bibr41-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-018-5449-4"},{"key":"bibr42-0846537120904347","doi-asserted-by":"crossref","unstructured":"Byrne D, Walsh JP, Schmiedeskamp H, et al. Prediction of hemorrhage after successful recanalization in patients with acute ischemic stroke: improved risk stratification using dual-energy CT parenchymal iodine concentration ratio relative to the superior sagittal sinus. AJNR Am J Neuroradiol [Internet]. 2020;41(1):64\u201370. http:\/\/dx.doi.org\/10.3174\/ajnr.A6345","DOI":"10.3174\/ajnr.A6345"},{"key":"bibr43-0846537120904347","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4350"},{"key":"bibr44-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1177\/1591019917694479"},{"key":"bibr45-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2017.12.024"},{"key":"bibr46-0846537120904347","doi-asserted-by":"crossref","unstructured":"Cho E-S, Chung T-S, Oh DK, et al. Cerebral computed tomography angiography using a low tube voltage (80 kVp) and a moderate concentration of iodine contrast material [Internet]. Invest Radiol. 2012;47(2):142\u2013147. http:\/\/dx.doi.org\/10.1097\/rli.0b013e31823076a4","DOI":"10.1097\/RLI.0b013e31823076a4"},{"key":"bibr47-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2018.01.008"},{"key":"bibr48-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-018-1981-9"},{"key":"bibr49-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1097\/RCT.0000000000000923"},{"key":"bibr50-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-017-1871-6"},{"key":"bibr51-0846537120904347","doi-asserted-by":"publisher","DOI":"10.3892\/etm.2016.3166"},{"key":"bibr52-0846537120904347","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.08.2290"},{"key":"bibr53-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1016\/j.crad.2010.03.002"},{"key":"bibr54-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1007\/s00062-013-0276-0"},{"key":"bibr55-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000391"},{"key":"bibr56-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1016\/j.jstrokecerebrovasdis.2017.02.036"},{"key":"bibr57-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-019-02170-8"},{"key":"bibr58-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-018-5534-8"},{"key":"bibr59-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1007\/s11604-017-0701-4"},{"key":"bibr60-0846537120904347","doi-asserted-by":"crossref","unstructured":"Demchuk AM, Dowlatshahi D, Rodriguez-Luna D, et al. Prediction of haematoma growth and outcome in patients with intracerebral haemorrhage using the CT-angiography spot sign (PREDICT): a prospective observational study [Internet]. Lancet Neurol. 2012;11(4):307\u2013314. http:\/\/dx.doi.org\/10.1016\/s1474-4422(12)70038-8","DOI":"10.1016\/S1474-4422(12)70038-8"},{"key":"bibr61-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2018180322"},{"issue":"1","key":"bibr62-0846537120904347","first-page":"190792","volume":"294","author":"Wiggins WF","year":"2019","journal-title":"Radiology"},{"key":"bibr63-0846537120904347","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5318"},{"key":"bibr64-0846537120904347","doi-asserted-by":"crossref","unstructured":"Bodanapally UK, Archer-Arroyo KL, Dreizin D, et al. Dual-energy computed tomography imaging of head: virtual high-energy monochromatic (190 keV) images are more reliable than standard 120 kV images for detecting traumatic intracranial hemorrhages [Internet]. J Neurotrauma. 2019;36(8):1375\u20131381. http:\/\/dx.doi.org\/10.1089\/neu.2018.5985","DOI":"10.1089\/neu.2018.5985"},{"key":"bibr65-0846537120904347","doi-asserted-by":"crossref","unstructured":"Bodanapally UK, Shanmuganathan K, Issa G, et al. Dual-energy CT in hemorrhagic progression of cerebral contusion: overestimation of hematoma volumes on standard 120-kV images and rectification with virtual high-energy monochromatic images after contrast-enhanced whole-body imaging [Internet]. Am J Neuroradiol. 2018;39(4):658\u2013662. http:\/\/dx.doi.org\/10.3174\/ajnr.a5558","DOI":"10.3174\/ajnr.A5558"},{"key":"bibr66-0846537120904347","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2890"},{"key":"bibr67-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2019190078"},{"key":"bibr68-0846537120904347","doi-asserted-by":"crossref","unstructured":"Bodanapally UK, Shanmuganathan K, Gunjan YP, Schwartzbauer G, Kondaveti R, Feiter TR. Quantification of Iodine leakage on dual-energy CT as a marker of blood-brain barrier permeability in traumatic hemorrhagic contusions: prediction of surgical intervention for intracranial pressure management [Internet]. Am J Neuroradiol. 2019;40(12):2059\u20132065. http:\/\/dx.doi.org\/10.3174\/ajnr.a6316","DOI":"10.3174\/ajnr.A6316"},{"key":"bibr69-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1177\/0284185118817906"},{"key":"bibr70-0846537120904347","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.19.21299"},{"key":"bibr71-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1017\/S0022215116001043"},{"key":"bibr72-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1080\/14737140.2019.1626234"},{"key":"bibr73-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2018.04.018"},{"key":"bibr74-0846537120904347","doi-asserted-by":"crossref","unstructured":"Laukamp KR, Zopfs D, Lennartz S, et al. Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts [Internet]. Eur Radiol. 2019;29(8):4228\u20134238. http:\/\/dx.doi.org\/10.1007\/s00330-018-5928-7","DOI":"10.1007\/s00330-018-5928-7"},{"key":"bibr75-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2018.05.034"},{"key":"bibr76-0846537120904347","doi-asserted-by":"crossref","unstructured":"Zeng Y, Deng K, Yang H, et al. Noise-optimised virtual monoenergetic imaging of dual-energy CT: effect on metal artefact reduction in patients with lumbar internal fixation [Internet]. Eur Spine J. 2019;28(8):1783\u20131792. http:\/\/dx.doi.org\/10.1007\/s00586-019-05984-5","DOI":"10.1007\/s00586-019-05984-5"},{"key":"bibr77-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-018-5411-5"},{"key":"bibr78-0846537120904347","doi-asserted-by":"crossref","unstructured":"Akisato K, Nishihara R, Okazaki H, et al. Dual-energy CT of material decomposition analysis for detection with bone marrow edema in patients with vertebral compression fractures [Internet]. Acad Radiol. 2020;27(2):227\u2013232. http:\/\/dx.doi.org\/10.1016\/j.acra.2019.02.015","DOI":"10.1016\/j.acra.2019.02.015"},{"key":"bibr79-0846537120904347","doi-asserted-by":"crossref","unstructured":"Neuhaus V, Lennartz S, Abdullayev N, et al. Bone marrow edema in traumatic vertebral compression fractures: diagnostic accuracy of dual-layer detector CT using calcium suppressed images [Internet]. Eur J Radiol. 2018;105:216\u2013220. http:\/\/dx.doi.org\/10.1016\/j.ejrad.2018.06.009","DOI":"10.1016\/j.ejrad.2018.06.009"},{"key":"bibr80-0846537120904347","doi-asserted-by":"crossref","unstructured":"Wang Y, Chen Y, Zheng H, Huang X, Shan C, Bao Y. Detection of different degree traumatic vertebral bone marrow oedema by virtual non-calcium technique of dual-source dual-energy CT [Internet]. Clin Radiol. 2020;75(2):156\u2013e11. http:\/\/dx.doi.org\/10.1016\/j.crad.2019.09.143","DOI":"10.1016\/j.crad.2019.09.143"},{"key":"bibr81-0846537120904347","doi-asserted-by":"crossref","unstructured":"Foti G, Beltramello A, Catania M, Rigotti S, Serra G, Carbognin G. Diagnostic accuracy of dual-energy CT and virtual non-calcium techniques to evaluate bone marrow edema in vertebral compression fractures [Internet]. Radiol Med. 2019;124(6):487\u2013494. http:\/\/dx.doi.org\/10.1007\/s11547-019-00998-x","DOI":"10.1007\/s11547-019-00998-x"},{"key":"bibr82-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2018181286"},{"key":"bibr83-0846537120904347","doi-asserted-by":"crossref","unstructured":"Pumberger M, Fuchs M, Engelhard N, et al. Disk injury in patients with vertebral fractures\u2014a prospective diagnostic accuracy study using dual-energy computed tomography [Internet]. Eur Radiol. 2019;29(8):4495\u20134502. http:\/\/dx.doi.org\/10.1007\/s00330-018-5963-4","DOI":"10.1007\/s00330-018-5963-4"},{"key":"bibr84-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2014-011241"},{"key":"bibr85-0846537120904347","doi-asserted-by":"publisher","DOI":"10.1097\/RCT.0000000000000779"}],"container-title":["Canadian Association of Radiologists Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0846537120904347","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0846537120904347","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0846537120904347","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T13:56:27Z","timestamp":1777384587000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0846537120904347"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,28]]},"references-count":85,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,8]]}},"alternative-id":["10.1177\/0846537120904347"],"URL":"https:\/\/doi.org\/10.1177\/0846537120904347","relation":{},"ISSN":["0846-5371","1488-2361"],"issn-type":[{"value":"0846-5371","type":"print"},{"value":"1488-2361","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,28]]}}}