{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T00:04:19Z","timestamp":1793837059822,"version":"4.6.1"},"reference-count":14,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2024,12,18]],"date-time":"2024-12-18T00:00:00Z","timestamp":1734480000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,12,18]],"date-time":"2024-12-18T00:00:00Z","timestamp":1734480000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Can Assoc Radiol J"],"published-print":{"date-parts":[[2025,8]]},"abstract":"<jats:p>\n                    <jats:bold>Purpose:<\/jats:bold>\n                    To determine the benefit of a FDG PET\/CT scan prior to CT-guided lung biopsy on the rate of diagnosis, rate of complication, and the identification of potentially safer biopsy sites.\n                    <jats:bold>Methods:<\/jats:bold>\n                    This retrospective observational cross-sectional study evaluated consecutive adult patients who underwent CT-guided lung biopsy in 2020 or 2021 at 2 Canadian tertiary care hospitals. These patients were grouped into those that had PET\/CT performed within 8 weeks prior to biopsy, within 8 weeks after biopsy, or no PET\/CT scan within this time frame. Biopsy complication rates and pathology diagnostic rates were compared. The PET\/CT images of those performed after biopsy were reviewed to determine if alternate safer biopsy sites could be identified. Categorical variables were compared using Pearson chi square test (\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt; .05 significant).\n                    <jats:bold>Results:<\/jats:bold>\n                    547 patients who had CT-guided lung biopsy were included. Patients with lung masses (\u22653 cm) who had a PET\/CT scan prior to biopsy had a higher diagnostic rate (90.8%) compared to those that did not (80.2%). The overall post-biopsy pneumothorax rate was 43.3% with 11.3% overall requiring chest tube insertion and 13.9% requiring hospitalization. There was no difference in complication rate for those who had PET\/CT prior to biopsy and those that did not. 28.9% to 42.1% of patients who had PET\/CT after biopsy had safer sites amenable to biopsy identified retrospectively outside of the lungs.\n                    <jats:bold>Conclusion:<\/jats:bold>\n                    PET\/CT prior to CT-guided lung biopsy improves the diagnostic rate in 10.6% of patients with lung masses (\u22653 cm) and identifies alternate safer sites to biopsy in 28.9% to 42.1% of patients (any size lesion).\n                  <\/jats:p>","DOI":"10.1177\/08465371241306731","type":"journal-article","created":{"date-parts":[[2024,12,18]],"date-time":"2024-12-18T10:27:03Z","timestamp":1734517623000},"page":"534-540","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":11,"title":["FDG PET\/CT Performed Prior to CT-Guided Percutaneous Biopsy of Lung Masses is Associated With an Increased Diagnostic Rate and Often Identifies Alternate Safer Sites to Biopsy"],"prefix":"10.1177","volume":"76","author":[{"given":"Jordan","family":"Haidey","sequence":"first","affiliation":[{"name":"Faculty of Medicine, University of Alberta, Edmonton, AB, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5311-1332","authenticated-orcid":false,"given":"Jonathan T.","family":"Abele","sequence":"additional","affiliation":[{"name":"Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2024,12,18]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacr.2021.03.015"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1177\/02841851231206349"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20190866"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.2147\/IJGM.S302434"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-0039-1688417"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111315"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.120.252403"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2019.04.016"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2019.04.017"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1007\/s13244-017-0561-6"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.21873\/invivo.13257"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00508-018-1317-0"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1259\/bjr20220339"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rcl.2018.01.009"}],"container-title":["Canadian Association of Radiologists Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/08465371241306731","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/08465371241306731","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/08465371241306731","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T13:55:13Z","timestamp":1777384513000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/08465371241306731"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,18]]},"references-count":14,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,8]]}},"alternative-id":["10.1177\/08465371241306731"],"URL":"https:\/\/doi.org\/10.1177\/08465371241306731","relation":{},"ISSN":["0846-5371","1488-2361"],"issn-type":[{"value":"0846-5371","type":"print"},{"value":"1488-2361","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,18]]}}}