{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T02:50:41Z","timestamp":1784083841961,"version":"3.55.0"},"reference-count":66,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2015,4,1]],"date-time":"2015-04-01T00:00:00Z","timestamp":1427846400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2015,4]]},"abstract":"<jats:p>\n                    Bioactive coatings are frequently used to improve the osseointegration of the metallic implants used in dentistry or orthopaedics. Among different types of bioactive coatings, hydroxyapatite (Ca\n                    <jats:sub>10<\/jats:sub>\n                    (PO\n                    <jats:sub>4<\/jats:sub>\n                    )\n                    <jats:sub>6<\/jats:sub>\n                    (OH)\n                    <jats:sub>2<\/jats:sub>\n                    ) is one of the most extensively used due to its chemical similarities to the components of bones and teeth. In this article, production and characterization of hydroxyapatite films deposited on Ti6Al4V alloy prepared by magnetron sputtering were reported. Besides, SiC was deposited on substrate surface to study the interlayer effect. Obtained coatings were annealed at 600 \u00b0C for 30 and 120\u2009min in a mixed atmosphere of N\n                    <jats:sub>2<\/jats:sub>\n                    \u2009+\u2009H\n                    <jats:sub>2<\/jats:sub>\n                    O vapours with the heating rate of 12 \u00b0C min\n                    <jats:sup>\u22121<\/jats:sup>\n                    . The effects of SiC interlayer and heat treatment parameters on the structural, mechanical and corrosion properties were investigated. After heat treatment process, the crystalline hydroxyapatite was obtained. Additionally, cell viability tests were performed. The results show that the presence of the SiC interlayer contributes a decrease in surface roughness and improves the mechanical properties and corrosion performance of the hydroxyapatite coatings. Biological properties were not affected by the presence of the SiC interlayer.\n                  <\/jats:p>","DOI":"10.1177\/0954411915578886","type":"journal-article","created":{"date-parts":[[2015,5,1]],"date-time":"2015-05-01T00:58:14Z","timestamp":1430441894000},"page":"307-318","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":13,"title":["Effect of SiC interlayer between Ti6Al4V alloy and hydroxyapatite films"],"prefix":"10.1177","volume":"229","author":[{"given":"Funda Ak","family":"Azem","sequence":"first","affiliation":[{"name":"Dokuz Eylul University, Faculty of Engineering, Department of Metallurgical and Materials Engineering, Izmir, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isil","family":"Birlik","sequence":"additional","affiliation":[{"name":"Dokuz Eylul University, Faculty of Engineering, Department of Metallurgical and Materials Engineering, Izmir, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Viorel","family":"Braic","sequence":"additional","affiliation":[{"name":"National Institute for Optoelectronics, Magurele, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mustafa","family":"Toparli","sequence":"additional","affiliation":[{"name":"Dokuz Eylul University, Faculty of Engineering, Department of Metallurgical and Materials Engineering, Izmir, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erdal","family":"Celik","sequence":"additional","affiliation":[{"name":"Dokuz Eylul University, Faculty of Engineering, Department of Metallurgical and Materials Engineering, Izmir, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anca","family":"Parau","sequence":"additional","affiliation":[{"name":"National Institute for Optoelectronics, Magurele, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adrian","family":"Kiss","sequence":"additional","affiliation":[{"name":"National Institute for Optoelectronics, Magurele, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Irina","family":"Titorencu","sequence":"additional","affiliation":[{"name":"Institute of Cellular Biology and Pathology Nicolae Simionescu of the Romanian Academy, Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alina","family":"Vladescu","sequence":"additional","affiliation":[{"name":"National Institute for Optoelectronics, Magurele, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2015,4,30]]},"reference":[{"key":"bibr1-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmst.2013.03.002"},{"key":"bibr2-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.surfcoat.2011.11.002"},{"key":"bibr3-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.mser.2009.05.001"},{"key":"bibr4-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2009.01.027"},{"key":"bibr5-0954411915578886","doi-asserted-by":"crossref","first-page":"267","DOI":"10.3928\/0147-7447-19940301-07","volume":"17","author":"Thomas KA","year":"1994","journal-title":"Orthopedics"},{"key":"bibr6-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.02.029"},{"key":"bibr7-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.matchar.2011.08.002"},{"key":"bibr8-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2010.01.002"},{"key":"bibr9-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.apsusc.2004.01.029"},{"key":"bibr10-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.apsusc.2011.04.051"},{"key":"bibr11-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-007-3135-1"},{"key":"bibr12-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(19990905)46:3<408::AID-JBM14>3.0.CO;2-Z"},{"key":"bibr13-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(199908)46:2<262::AID-JBM16>3.0.CO;2-1"},{"key":"bibr14-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2009.01.107"},{"key":"bibr15-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2005.01.014"},{"key":"bibr16-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.30168"},{"key":"bibr17-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2010.06.036"},{"key":"bibr18-0954411915578886","first-page":"133","author":"Ordine A","year":"2000","journal-title":"Surf Coat Tech"},{"key":"bibr19-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.surfcoat.2009.10.018"},{"key":"bibr20-0954411915578886","first-page":"17","volume-title":"Silicon carbide biotechnology: a biocompatible semiconductor for advanced biomedical devices and applications","author":"Locke CW","year":"2011"},{"key":"bibr21-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1088\/0022-3727\/40\/20\/S20"},{"key":"bibr22-0954411915578886","first-page":"1","volume":"22","author":"Andrievski RA","year":"2009","journal-title":"Rev Adv Mater Sci"},{"key":"bibr23-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2007.08.043"},{"key":"bibr24-0954411915578886","unstructured":"Food and Drug Administration (FDA). Rithron-XR Coronary Stent System \u2013 P030037, 2005, p.1, http:\/\/www.fda.gov\/MedicalDevices\/ProductsandMedicalProcedures\/DeviceApprovalsandClearances\/Recently-ApprovedDevices\/ucm078628.htm"},{"key":"bibr25-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4615-5517-9_2"},{"key":"bibr26-0954411915578886","doi-asserted-by":"publisher","DOI":"10.6028\/jres.108.017"},{"key":"bibr27-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1186\/1752-153X-5-40"},{"key":"bibr28-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/S0257-8972(02)00363-8"},{"key":"bibr29-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/0267-6605(93)90049-D"},{"key":"bibr30-0954411915578886","first-page":"1047","volume":"14","author":"Parau AC","year":"2012","journal-title":"Optoelectron Adv Mat"},{"key":"bibr31-0954411915578886","first-page":"1132","volume":"11","author":"Stan GE","year":"2009","journal-title":"Optoelectron Adv Mat"},{"key":"bibr32-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(96)89656-6"},{"key":"bibr33-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.tsf.2007.02.089"},{"key":"bibr34-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2008.08.036"},{"key":"bibr35-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrysgro.2007.11.001"},{"key":"bibr36-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1177\/00220345630420051301"},{"key":"bibr37-0954411915578886","unstructured":"IBIS nanoindentation system manual. Sydney, NSW, Australia: Fischer-Cripps Laboratories Pty Ltd, 2008, http:\/\/www.lot-qd.de\/files\/downloads\/fischer-cripps\/uk\/IBIS_ProductInfoDetail.pdf"},{"key":"bibr38-0954411915578886","unstructured":"ASTM G59-97:1997. Standard test method for conducting potentiodynamic polarization resistance measurements."},{"key":"bibr39-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1006\/abbi.1993.1311"},{"key":"bibr40-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(19980315)39:4<524::AID-JBM3>3.0.CO;2-L"},{"key":"bibr41-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1002\/ppap.200400094"},{"key":"bibr42-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.surfcoat.2012.12.037"},{"key":"bibr43-0954411915578886","first-page":"744","author":"Rapacz-Kmita A","year":"2005","journal-title":"J Mol Struct"},{"key":"bibr44-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3697(02)00257-3"},{"key":"bibr45-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/S0006-3495(91)82113-0"},{"key":"bibr46-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.10280"},{"key":"bibr47-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-007-3261-9"},{"key":"bibr48-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-2860(00)00623-2"},{"key":"bibr49-0954411915578886","doi-asserted-by":"publisher","DOI":"10.5545\/sv-jme.2010.140"},{"key":"bibr50-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2007.03.032"},{"key":"bibr51-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.10537"},{"key":"bibr52-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(19990615)45:4<370::AID-JBM12>3.0.CO;2-0"},{"key":"bibr53-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1063\/1.4752470"},{"key":"bibr54-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1016\/S1359-6454(01)00238-5"},{"key":"bibr55-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1007\/BF02666659"},{"key":"bibr56-0954411915578886","doi-asserted-by":"publisher","DOI":"10.2320\/matertrans.MER2008055"},{"key":"bibr57-0954411915578886","volume-title":"Comprehensive biomaterials","author":"Ducheyne P","year":"2011","edition":"1"},{"key":"bibr58-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820270105"},{"key":"bibr59-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4684-8986-6_3"},{"key":"bibr60-0954411915578886","first-page":"107","volume-title":"Corrosion tests and standards: application and interpretation","author":"Hack H","year":"2005"},{"key":"bibr61-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.1056"},{"key":"bibr62-0954411915578886","doi-asserted-by":"publisher","DOI":"10.3724\/SP.J.1077.2011.11125"},{"key":"bibr63-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1243\/09544119JEIM900"},{"key":"bibr64-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1243\/09544119JEIM901"},{"key":"bibr65-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1007\/s13758-012-0046-6"},{"key":"bibr66-0954411915578886","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.30320"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0954411915578886","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0954411915578886","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0954411915578886","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:22:04Z","timestamp":1777674124000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0954411915578886"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,4]]},"references-count":66,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2015,4]]}},"alternative-id":["10.1177\/0954411915578886"],"URL":"https:\/\/doi.org\/10.1177\/0954411915578886","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,4]]}}}