{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T02:26:26Z","timestamp":1790303186805,"version":"4.1.0"},"reference-count":35,"publisher":"SAGE Publications","issue":"7","license":[{"start":{"date-parts":[[2016,5,3]],"date-time":"2016-05-03T00:00:00Z","timestamp":1462233600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2016,7]]},"abstract":"<jats:p>In the transradial limb\u2013socket contact interface, the physiological properties and prosthetic operating habits of the residual limb might affect the comfort and functionality of the prosthesis. To enhance the comfort and functionality of the interface, a frame-type socket with four volume-adjustable compression chambers was proposed for the transradial amputation level. The contact pressure of the limb\u2013socket interface was adjusted by the volume changes in the chambers and controlled by a vacuum pump and the corresponding control system. The parameters of the chamber were designed in accordance with the biomechanics of the forearm soft tissue. The chamber with a negative stiffness characteristic was theoretically compared with the chamber with a positive stiffness characteristic. The results showed that the former had a superior performance to the latter in safety and pump performance requirements. A physical model of the transradial frame-type prosthetic interface was also manufactured with four negative stiffness chambers. The experimental results showed that this new prosthetic interface achieved more fitting time and better performance in comfort and functionality than the fixed frame-type socket. This new prosthetic interface with volume-adjustable compression chambers might be an alternative choice for transradial amputees.<\/jats:p>","DOI":"10.1177\/0954411916645132","type":"journal-article","created":{"date-parts":[[2016,5,4]],"date-time":"2016-05-04T21:03:27Z","timestamp":1462395807000},"page":"650-660","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":10,"title":["Characteristics of a volume-adjustable compression chamber for transradial prosthetic interface"],"prefix":"10.1177","volume":"230","author":[{"given":"Yuanjun","family":"Sang","sequence":"first","affiliation":[{"name":"State Key Laboratory of Mechanical System and Vibration, Institute of Biomedical Manufacturing and Life Quality Engineering, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiang","family":"Li","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Mechanical System and Vibration, Institute of Biomedical Manufacturing and Life Quality Engineering, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yun","family":"Luo","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Mechanical System and Vibration, Institute of Biomedical Manufacturing and Life Quality Engineering, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2016,5,3]]},"reference":[{"key":"bibr1-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1080\/09638280410001645094"},{"key":"bibr2-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1016\/j.mporth.2010.10.003"},{"key":"bibr3-0954411916645132","first-page":"2276","volume-title":"Proceedings of the 20th annual international conference of the IEEE engineering in medicine and biology society","author":"Plettenburg DH"},{"key":"bibr4-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1080\/17483100701714733"},{"key":"bibr5-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2004.08.015"},{"key":"bibr6-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1097\/JPO.0b013e31817d2f08"},{"key":"bibr7-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2007.05.011"},{"key":"bibr8-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1080\/09638280410001708850"},{"key":"bibr9-0954411916645132","doi-asserted-by":"publisher","DOI":"10.3109\/03093648609164504"},{"key":"bibr10-0954411916645132","unstructured":"Alley RD. Advancement of upper extremity prosthetic interface and frame design. In: Proceedings of the 2002 myoelectric symposium, 2002, http:\/\/dukespace.lib.duke.edu\/dspace\/bitstream\/handle\/10161\/2684\/r_alley_paper01.pdf?sequence=3"},{"key":"bibr11-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1097\/00008526-200310000-00007"},{"key":"bibr12-0954411916645132","first-page":"1","volume":"5","author":"Alley RD.","year":"2009","journal-title":"Acad Today"},{"key":"bibr13-0954411916645132","unstructured":"Alley RD. The high-fidelity interface skeletal stabilization through alternating soft tissue. In: Proceedings of the 2011 myoelectric controls\/powered prosthetics symposium fredericton, 2011, http:\/\/dukespace.lib.duke.edu\/dspace\/bitstream\/handle\/10161\/4746\/59%20Alley.pdf?sequence=1"},{"key":"bibr14-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1016\/S1350-4533(99)00089-2"},{"key":"bibr15-0954411916645132","first-page":"161","volume":"38","author":"Mak AFT","year":"2001","journal-title":"J Rehabil Res Dev"},{"key":"bibr16-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1177\/0309364611409003"},{"key":"bibr17-0954411916645132","first-page":"188","volume":"31","author":"Mak AFT","year":"1994","journal-title":"J Rehabil Res Dev"},{"key":"bibr18-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1109\/86.788463"},{"key":"bibr19-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1016\/S1350-4533(97)00017-9"},{"key":"bibr20-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1115\/1.4005865"},{"key":"bibr21-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1115\/1.4028705"},{"key":"bibr22-0954411916645132","volume-title":"Design of a transradial socket","author":"Steinbuch M.","year":"2010"},{"key":"bibr23-0954411916645132","unstructured":"Bertels T, Kettwig T. Breathable liner for transradial prostheses. In: Proceedings of the 2011 myoelectric symposium, 2011, http:\/\/dukespace.lib.duke.edu\/dspace\/bitstream\/handle\/10161\/4719\/15%20Bertels.pdf?sequence=1"},{"key":"bibr24-0954411916645132","first-page":"11","volume":"11","author":"Wilson AB","year":"1987","journal-title":"Clin Prosthet Orthot"},{"key":"bibr25-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1097\/00008526-199307000-00003"},{"key":"bibr26-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1682\/JRRD.2010.09.0189"},{"key":"bibr27-0954411916645132","first-page":"365","volume":"38","author":"Sanders JE","year":"2001","journal-title":"J Rehabil Res Dev"},{"key":"bibr28-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1097\/00008526-200307000-00011"},{"key":"bibr29-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1080\/03093640600810266"},{"key":"bibr30-0954411916645132","first-page":"330","volume-title":"30th annual international conference of the IEEE engineering in medicine and biology society (EMBS 2008)","author":"Ogawa A"},{"key":"bibr31-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtbi.2011.08.022"},{"key":"bibr32-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2008.03.039"},{"key":"bibr33-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.01115.2006"},{"key":"bibr34-0954411916645132","doi-asserted-by":"publisher","DOI":"10.1007\/s10237-012-0397-4"},{"key":"bibr35-0954411916645132","doi-asserted-by":"publisher","DOI":"10.12968\/jowc.2000.9.1.25939"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0954411916645132","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0954411916645132","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0954411916645132","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:22:54Z","timestamp":1777674174000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0954411916645132"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5,3]]},"references-count":35,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2016,7]]}},"alternative-id":["10.1177\/0954411916645132"],"URL":"https:\/\/doi.org\/10.1177\/0954411916645132","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,5,3]]}}}