{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T20:33:47Z","timestamp":1777926827196,"version":"3.51.4"},"reference-count":35,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2017,11,30]],"date-time":"2017-11-30T00:00:00Z","timestamp":1512000000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2018,1]]},"abstract":"<jats:p>Contact pressure and stresses on the articulating surface of the tibial component of a total knee replacement are directly related to the joint contact forces and the contact area. These stresses can result in wear and fatigue damage of the ultra-high-molecular-weight polyethylene. Therefore, conducting stress analysis on a newly designed surface-guided knee implant is necessary to evaluate the design with respect to the polyethylene wear. Finite element modeling is used to analyze the design\u2019s performance in level walking, stair ascending and squatting. Two different constitutive material models have been used for the tibia component to evaluate the effect of material properties on the stress distribution. The contact pressure results of the finite element analysis are compared with the results of contact pressure using pressure-sensitive film tests. In both analyses, the average contact pressure remains below the material limits of ultra-high-molecular-weight polyethylene insert. The peak von Mises stresses in 90\u00b0 of flexion and 120\u00b0 of flexion (squatting) are 16.28 and 29.55\u2009MPa, respectively. All the peak stresses are less than the fatigue failure limit of ultra-high-molecular-weight polyethylene which is 32\u2009MPa. The average contact pressure during 90\u00b0 and 120\u00b0 of flexion in squatting are 5.51 and 5.46\u2009MPa according to finite element analysis and 5.67 and 8.14\u2009MPa according to pressure-sensitive film experiment. Surface-guided knee implants are aimed to resolve the limitations in activities of daily living after total knee replacement by providing close to normal kinematics. The proposed knee implant model provides patterns of motion much closer to the natural target, especially as the knee flexes to higher degrees during squatting.<\/jats:p>","DOI":"10.1177\/0954411917744586","type":"journal-article","created":{"date-parts":[[2017,12,1]],"date-time":"2017-12-01T02:08:02Z","timestamp":1512094082000},"page":"90-100","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":7,"title":["Customized surface-guided knee implant: Contact analysis and experimental test"],"prefix":"10.1177","volume":"232","author":[{"given":"Ida","family":"Khosravipour","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shabnam","family":"Pejhan","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yunhua","family":"Luo","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Urs P","family":"Wyss","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2017,11,30]]},"reference":[{"key":"bibr1-0954411917744586","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.00067"},{"key":"bibr2-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2474-8-91"},{"key":"bibr3-0954411917744586","doi-asserted-by":"publisher","DOI":"10.2174\/1874120701004010085"},{"key":"bibr4-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/j.wear.2015.02.048"},{"key":"bibr5-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/S0043-1648(03)00357-0"},{"key":"bibr6-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1002\/1097-4636(2001)58:3<282::AID-JBM1018>3.0.CO;2-S"},{"key":"bibr7-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2001.21501"},{"key":"bibr8-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200111000-00029"},{"key":"bibr9-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2014.12.012"},{"key":"bibr10-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/S0268-0033(00)00040-1"},{"key":"bibr11-0954411917744586","volume-title":"Design features and kinematic behavior of a customized surface-guided knee implant","author":"Pejhan S","year":"2015"},{"key":"bibr12-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1177\/0954411916663839"},{"key":"bibr13-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1115\/1.4003675"},{"key":"bibr14-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1007\/3-540-27658-0"},{"key":"bibr15-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1115\/1.2796020"},{"key":"bibr16-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1243\/0954411981533971"},{"key":"bibr17-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(01)00179-8"},{"key":"bibr18-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(03)00255-0"},{"key":"bibr19-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/S0268-0033(02)00102-X"},{"key":"bibr20-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2010.02.020"},{"key":"bibr21-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(01)00172-5"},{"key":"bibr22-0954411917744586","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-200701000-00006"},{"key":"bibr23-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2007.09.005"},{"key":"bibr24-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1108\/13552540610682705"},{"key":"bibr25-0954411917744586","unstructured":"Kurtz S. UHMWPE biomaterials handbook: ultra high molecular weight polyethylene in total joint replacement and medical devices, vol. 89. Amsterdam: Elsevier, 2009, pp.780\u2013785."},{"key":"bibr26-0954411917744586","volume-title":"Nonlinear viscoelastic behaviour of irradiated ultra-high molecular weight polyethylene at 37 degrees Celsius","author":"Waldman SD","year":"1994"},{"key":"bibr27-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-79306-6_8"},{"key":"bibr28-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199612000-00008"},{"key":"bibr29-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.09.027"},{"key":"bibr30-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-08099-4_13"},{"key":"bibr31-0954411917744586","volume-title":"Failure mechanisms on total knee arthroplasty","author":"McTighe T","year":"2009"},{"key":"bibr32-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0086035"},{"key":"bibr33-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2007.05.004"},{"key":"bibr34-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2010.09.007"},{"key":"bibr35-0954411917744586","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200211000-00030"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0954411917744586","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0954411917744586","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0954411917744586","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:23:52Z","timestamp":1777674232000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0954411917744586"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11,30]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,1]]}},"alternative-id":["10.1177\/0954411917744586"],"URL":"https:\/\/doi.org\/10.1177\/0954411917744586","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,11,30]]}}}